feb 12, 2007 revised to feb 26, 2007 page 1 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet description the fnp600/850/1000 power factor correct ed (pfc) front ends provide (depending on model) either a 12 vdc or a 48 vdc output for telecom, datacom, and ot her distributed power applications. their small 1u by 2u size allows for configurations of either height in hot-swap redundant system s while their internal fan and cooling design permits wide use with reliable operatio n. status is provided with front panel leds, logic signals, and via the i 2 c management interface bus. in addition, the i 2 c bus can enable the power supply, control fan speed, and on the 12 vdc mode ls it allows for adjusting the output voltage from 7 to 12 vdc. this powerful feature allows the same power supply to be used in various applications where bus voltages driving isolated dc-dc converters and pol regulators may be different. also, the fnp850-12r is uniquely designed with airflow from the rear of the power supply to the front. this airflow direction supports those critical applications where space limitations and/or higher ambient temper atures near the rear of the rack syste m, prohibit the discharge of higher te mperature airflow from regular fr ont-to-rear cooled power supplies. the fnp600/850/1000's meet international safety requirement s and are ce marked to the low voltage directive (lvd). features ? rohs lead free solder and lead solder exempted products are available ? high density front-ends 10.5 to 16.1 w/in 3 ? universal input voltage range (90-264 vac) with pfc ? 1u or 2u height configurations ? droop current share with oring fets ? i 2 c interface status and control ? standby voltage of 12 vdc @ 0.5 a ? overtemperature, overload, and overvoltage protection ? status leds: ac ok, dc ok, overtemperature ? fnp850-12 model has airflow direction from front-to-rear or from rear-to-front (-12r model) applications ? telecom ? datacom ? distributed power systems 600-to-5000-watt front-end power solutions i 2 c management software : all fnp front-ends can be controlled via power-one's gui-driven i 2 c management software and an i 2 c-to-usb interface (p/n hzz02002g). an i 2 c programming manual describes the complete range of parameters that can be programmed to these front-ends. this manual is available by searching on "fnp600" at www. p owe r -one.com . (600, 850, or 1000 watts) fnr-5 power shelf fnr-5-48 power shelves provide up to 5000 watts in a 19" rack. (see the rack section for power shelf details.)
feb 12, 2007 revised to feb 26, 2007 page 2 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet model selection model nominal output voltage (vdc) 1 adjustment range (vdc) maximum output current (amps) line regulation (%) load regulation (%) 2 ripple & noise pk-pk % 3 compatible shelf fnp600-12 12 12 (standby) 7 to 12 n/a 51 0.5 0.17 8 6 8 1 1 fnr-5-12 fnp850-12 12 12 (standby) 7 to 12 n/a 73 0.5 0.17 8 6 8 1 1 fnr-5-12 fnp850-12r 4 12 12 (standby) 7 to 12 n/a 73 0.5 0.17 8 6 8 1 1 fnr-5-12 fnp600-48 48 12 (standby) n/a 12.6 0.5 0.17 8 6 8 1 1 fnr-5-48 fnp1000-48 48 12 (standby) n/a 21 0.5 0.17 8 6 8 1 1 fnr-5-48 1 models with 5v and 3.3v standby voltages are also available. (contact factory.) 2 primary 12v and 48v outputs have built-in droop regulation. 3 maximum peak-to-peak noise expressed as a percentage of output voltage; 20 mhz bandwidth. 4 fnp850-12r model has airflow from rear to front. ordering information options suffixes to add to part number rohs lead solder exemption no rohs suffix character required. rohs compliant for all 6 substances add "g" as the last character of the part number. input specifications parameter conditions/descripti on min. nom. max. units ac input voltage single-phase c ontinuous input range. 90 264 vac input frequency ac input. 47 63 hz hold-up time after last ac line peak at full power. at 115 vac. 20 1 ms input current at full-rated load. at 90 vac. 14 a rms inrush surge current internally limited. vin = 230 vac. 25 oc 34 a pk power factor per en61000-3-2 0.97 w/va 1 fnp1000-48 model has a hold-up time of 16 ms. feb 12, 2007 revised to feb 26, 2007 page 3 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet output specifications parameter conditions/descripti on min. nom. max. units efficiency: fnp600-48 fnp1000-48 fnp600-12 fnp850-12 full rated load at 230 vac input. 88 88 84 84 89.5 89.5 87 87 % minimum load minimum loading required to maintain regulation. 0 a output power fnp1000 fnp850 fnp600 1006 856 600 w overshoot output voltage overshoot at turn-on. 3 % transient response maximum recovery time to within 1% of initial set point due to a 50% load change, 1a/s. 12v or 48v output: standby output: maximum deviation: 12v or 48v output: standby output: 400 2 2 4 s ms % % turn-on delay time required for initial output voltage stabilization after application of ac input.. 1.5 sec output regulation see model selection table. protection parameter conditions/descripti on min. nom. max. units fnp600-12 & fnp850-12 latch-style overvoltage protection. output adjusted to 12v: 14.4 15 15.6 v fnp600-12: fnp850-12: latch-style overvoltage protection. output adjusted to 7v: 8.75 8.44 9.04 8.75 9.33 9.1 v overvoltage protection fnp600-48 & fnp1000-48 latch-style overvoltage protection. output adjusted to 48v: 57 1 60 v fnp600-12 current limit.12v output: 12v standby output: 54 0.55 56 0.75 61 1.0 a fnp850-12 current limit.12v output: 12v standby output: 77 0.55 80 0.75 88 1.0 a fnp600-48 current limit.48v output: 12v standby output: 13 0.75 14 16 1.75 a overcurrent protection (power supply recovers when short is removed.) fnp1000-48 current limit.48v output: 12v standby output: 22 0.75 23 25 1.75 a short-circuit protection power supply recovers when short is removed. overtemperature/ fan failure warning fnp 12v or 48v vo1 supply output will shut down in the event of an overtemper ature condition or blocked fan rotor. supply's fan and vaux are active. power supply will recover when ot condition is removed. amber ot led will turn on to indicate fault condition. ot/fan fail is an open-collector signal with 20-ma pu ll-down. high signal indicates a normal operating condition. output will go low at least 100 ms bef ore ot condition shuts down the power supply. 1 fnp1000-48 overvoltage protection rang e is 56 v minimum and 60 v maximum. feb 12, 2007 revised to feb 26, 2007 page 4 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet control and monitoring parameter conditions/descripti on min. nom. max. units dc ok ttl open-collector signal with active 20-ma pull-down. represents percent of output voltage where signal is ok. below this voltage, a signal high condition indicates an output which is out of tolerance. green dc ok led on front panel indicates normal operation. 1 90 110 % input power fail warning ttl open-collector signal with active 20-ma pull-down. high indicates an input power fail. power fail warning will turn off green ac ok led. represents the time after warning signal before vout drops to 95% due to loss of input power. 1 5 ms power supply present signal resistance of connection to logic ground which allows user to determine if power supply is present. 1 10 ? fnp600-12: main output only. difference in current between two supplies at >10% load value. 5 fnp850-12: 7 fnp600-48: 2 current share fnp1000-48: 2 a remote sense total voltage compensation for cable losses with respect to the main output. 0.5 v output enable open circuit or logic high from ena pin to vo1 rtn shuts off vo1; vaux and fan are operational. logic low (2 ma sink capability) or jumper will turn on vo1 within 100 ms. open circuit voltage on enable pin is 3.3 vdc. externally applied voltage to the enable pin should not exceed 7 vdc. signal is referred to as logic return (lrtn). 1 also available on i 2 c data line. i 2 c bus management interface static includes static information such as: part number and re vision level, output rating, serial number, date code, and manufacturing location. status (logic 1 or 0) power supply ok. ac input ok. dc output ok. power supply seated. overtemperature. overcurrent. fan ok. real-time monitoring output voltage (main output) 0.1v lsd. output current (main output) 0.1a lsd. time in service. control signals enable for main output. output voltage to: (0.01v resolution on 12v supplies; 0.05v resolution on all 48v supplies). fan speed level. feb 12, 2007 revised to feb 26, 2007 page 5 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet safety, regulatory, and emi specifications parameter conditions/descripti on min. nom. max. units agency approvals ul60950, (ul) csa 60950 (cul), en60950 (tv), ce mark for lvd. electromagnetic interference fcc cfr title 47 part 15 sub-part b, conducted: en55022/cispr 22. radiated: b a class harmonics per iec61000-3-2. a class voltage fluctuation and flicker per iec61000-3-3. pass esd susceptability per en61000-4-2, level 4. 8 . kv radiated susceptability per en 61000-4-3, level 3. 10 . v/m eft/burst per en 61000-4-4, level 4. 4 . kv input transient protection per en 61000-4-5, class 3. line-to-line: line-to-ground: 1 2 . kv rf conducted disturbances per en 61000-4-6, level 3. 10 . v voltage interruptions per en 61000-4-11, performance criterion b 30%. per en 61000-4-11, performance criterion c 60%. per en 61000-4-11, performance criterion c 95%. 10 100 5 . ms ms sec voltage sag immunity per semi f47-0999 > 100 vac. no output voltage interruption. . leakage current per en60950. at 240 vac: 3.5 ma environmental specifications parameter conditions/descripti on min. nom. max. units altitude operating. non-operating. 10k 40k asl ft asl ft fnp600-12: fnp850-12: fnp600-48: fnp1000-48: internal dc fan for cooling. at 100% load: at 50% load: 0 0 50 70 oc operating temperature fnp850-12r: internal dc fan for cooling. at 100% load: at 94% load: at 50% load: 0 0 0 40 50 70 oc storage temperature -40 85 oc temperature coefficient 0 oc to 70 oc (after 15-minute warm-up). 0.02 %/oc relative humidity non-condensing 95 %rh shock operating: half-sine, 10 ms, 3-axis. non-operating: half-sine, 10 ms, 3-axis. +20 +40 gpk gpk vibration operating: swept sine 5-2000-5 hz, 5-32 hz, 0.02?da, 32-2000 hz. non-operating: random 10-2000 hz. 1 6.15 gpk grms reliability parameter conditions/descripti on min. nom. max. units mtbf (calculated) milhdbk 217f ground benign. demonstrated. useful life. 100 000 250 000 10 hrs hrs yrs feb 12, 2007 revised to feb 26, 2007 page 6 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet mechanical drawings feb 12, 2007 revised to feb 26, 2007 page 7 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet feb 12, 2007 revised to feb 26, 2007 page 8 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet connector information power supply: input - iec 320 input (male) standard line cord connection output - p/n fci 51732-020 mating connections: input - iec 320 output (socket) standard line cord (15a) output - p/n: fci 51742-020 (backplane) p/n: fci 51762-020 (right angle) input iec connector input location chassis (safety) ground ground line 1 (line) l line 2 (neutral) n feb 12, 2007 revised to feb 26, 2007 page 9 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet output pin assignments signal pin location ground reference overtemperature / fan fail u1 logic groun d (internal 10r connection to aux ground) ac power fail warning u2 logic ground (internal 10r connection to aux ground) power supply present u3 logic ground (i nternal 10r connection to aux ground) output voltage fault u4 logic ground (internal 10r connection to aux ground) internal ground u5 internal ground (external connected with vsense-) addr0, i 2 c address bus t1 internal ground (external connected with vsense-) addr1, i 2 c address bus t2 internal ground (external connected with vsense-) addr2, i 2 c address bus t3 internal ground (external connected with vsense-) addr3, i 2 c address bus t4 internal ground (external connected with vsense-) addr4, i 2 c address bus t5 internal ground (external connected with vsense-) data, i 2 c data line s1 logic ground (internal 10r connection to aux ground) clock, i 2 c clock line s2 logic ground (internal 10r connection to aux ground) auxiliary power +12v s3 aux ground auxiliary power ground s4 aux ground logic ground s5 logic ground (internal 10r connection to aux ground) output enable 1 r1 logic ground (internal 10r connection to aux ground) vsense+ r2 vsense- vsense- r3 vsense- output margin r4 vsense- reserve r5 vsense- vout+ p1, p2, p3 vsense- vout- p4, p5, p6 vsense- 1 short pin length feb 12, 2007 revised to feb 26, 2007 page 10 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet racks (fnr-5-12 and fnr-5-48 power shelves) each rack (power shelf) is 1u high with backplane and designed for up to five front-end models in parallel or in n+1 operation. each power shelf has: ? output terminals with two m4-screws on each power tab. ? two fast-on contacts for system earthing. ? address coding over five pole dip switch on each unit, 37-pin d-sub connector with i 2 c-lines, monitoring signals and support functions. ? provides a start-up synchronizat ion circuit and emv filters. fnr-5-12 and fnr-5-48 power shelf front view overall mechanical dimensions (fnr-5-12 and fnr-5-48 power shelves) fnr-5-12 & fnr-5-48 mechanical data (w, h, d) 17.68? (449 mm) x 1.72? (43.6 mm) x 13.05? (331.5 mm) feb 12, 2007 revised to feb 26, 2007 page 11 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet output connector descriptions (fnr-5-12 & fnr-5-48) location description a 5-bit dip switch for i 2 c addressing of psu 1 b 5-bit dip switch for i 2 c addressing of psu 2 c 37-pin sub-d connector, controlli ng and auxiliary power (output 2) d 5-bit dip switch for i 2 c addressing of psu 3 e output 1 minus f output 1 plus g 5-bit dip switch for i 2 c addressing of psu 4 h earth connection i 5-bit dip switch for i 2 c addressing of psu 5 mechanical data (fnr-5-12 and fnr-5-48 power shelves) a b c d e f g h i feb 12, 2007 revised to feb 26, 2007 page 12 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet accessories: center angular brackets are set in the middle for shelf mounting: center angular bracket sets can be ordered: power-one part no.: hzz01222 note: each center angular bracket set contains 2 brackets and 8 screws. feb 12, 2007 revised to feb 26, 2007 page 13 of 13 www.power-one.com fnp600/850/1000 ac-dc front-ends & fnr-5-12/fnr-5-48 power shelves data sheet i 2 c to usb interface demonstration kit hzz02002g : an i 2 c to usb interface demonstration ki t can be ordered: power-one part no.: hzz02002g nuclear and medical applications - power-one products are not des igned, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous envir onments, or nuclear control systems without the express wr itten consent of the respective divisional pr esident of power-one, inc. technical revisions - the appearance of products, including safe ty agency certifications pictured on labels, may change dependi ng on the date manufactured. specifications ar e subject to change without notice. i 2 c |
Price & Availability of 12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |