PART |
Description |
Maker |
CT131 |
Contact Form: 1a Load Voltage: 350V Maximum
|
Coto Technology
|
C574S |
Contact Form: C574S: 1b / C674S: 2b Load Voltage: 400V Maximum
|
Coto Technology
|
CS147 |
Contact Form: 1a Load Voltage: 80V Maximum
|
Coto Technology
|
AQV414SX |
PhotoMOS relay, GU (general use) type [1-channel (form B) type]. AC/DC type. Output rating: load voltage 400 V, load current 100 mA. Picked from the 1/2/3-pin side
|
Matsushita Electric Works(Nais)
|
AQV234AX AQV234AZ AQV234 AQV234A |
PhotoMOS relay, HS (high sensitivity) type [1-channel (form A) type]. Output rating: load voltage 400 V, load current 120 mA. Surface-mount terminal. Tube packing style. PhotoMOS relay, HS (high sensitivity) type [1-channel (form A) type]. Output rating: load voltage 400 V, load current 120 mA. Surface-mount terminal. Tape and reel packing style, picked from the 4/5/6-pin side. PhotoMOS relay, HS (high sensitivity) type [1-channel (form A) type]. Output rating: load voltage 400 V, load current 120 mA. Surface-mount terminal. Tape and reel packing style, picked from the 1/2/3-pin side.. PhotoMOS relay, HS (high sensitivity) type [1-channel (form A) type]. Output rating: load voltage 400 V, load current 120 mA. Through hole terminal. Tupe packing style.
|
Matsushita Electric Works(Nais) NAIS[Nais(Matsushita Electric Works)]
|
MAX1044 MAX1044CPA MAX1044CSA MAX1044EPA MAX1044ES |
From old datasheet system Analog IC - Datasheet Reference Switched-Capacitor Voltage Converters Apem Components Inc Micro Limit Switches, Contact Rating: 16 A/250 VAC (resistive load), 4 A/250 VAC (motor load), Contact Type: SPST-NO, Actuator: Roller Lever, Contact: Nickel Silver
|
Maxim Integrated Produc... MAXIM - Dallas Semiconductor MAXIM[Maxim Integrated Products] Maixm Maxim Integrated Products Inc Maxim Integrated Products, Inc.
|
AQW210HLAX AQW210HLAZ AQW210HL AQW210HLA |
PhotoMOS relay, GU (general use) type, 2-ch (form A) current limit function type. AC/DC type. I/O isolation: 5,000 VAC. Output rating: load voltage 350 V, load current 120 mA. Surface-mount. Tape and reel packing style. Picked from the 4/5 PhotoMOS relay, GU (general use) type, 2-ch (form A) current limit function type. AC/DC type. I/O isolation: 5,000 VAC. Output rating: load voltage 350 V, load current 120 mA. Surface-mount. Tube packing style. PhotoMOS relay, GU (general use) type, 2-ch (form A) current limit function type. AC/DC type. I/O isolation: 5,000 VAC. Output rating: load voltage 350 V, load current 120 mA. Surface-mount. Tape and reel packing style. Picked from the 1/2 PhotoMOS relay, GU (general use) type, 2-ch (form A) current limit function type. AC/DC type. I/O isolation: 5,000 VAC. Output rating: load voltage 350 V, load current 120 mA. Trough hole terminal. Tube packing style. GU (General Use) Type 2-Channel (Form A) Current Limit Function Type
|
Matsushita Electric Works(Nais) NAIS[Nais(Matsushita Electric Works)]
|
3-1419108-9 3-1419108-6 3-1419108-1 RT314024F 5-14 |
Power PCB Relay RT1 5kV/10mm coil-contact, reinforced insulation 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
|
Tyco Electronics TE Connectivity Ltd
|
AQW414AZ AQW414AX |
PhotoMOS relay, GU (general use) type, [2-channel (form B) type]. AC/DC type. Output rating: load voltage 400 V, load current 100 mA. Surface-mount terminal, tape and reel packing style, picked from the 4/5/6-pin side. PhotoMOS relay, GU (general use) type, [2-channel (form B) type]. AC/DC type. Output rating: load voltage 400 V, load current 100 mA. Surface-mount terminal, tape and reel packing style, picked from the 1/2/3-pin side.
|
Matsushita Electric Works(Nais)
|
AEV25012 AEV25024 AEV25112 AEV25124 AEV25312 AEV25 |
EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 30A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 30A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 60A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 60A. Without indicator contact.
|
Matsushita Electric Works(Nais)
|
|