Previous Datasheet Index Next Data Sheet Bulletin I27402 IRKD600.. SERIES STANDARD DIODES SUPER MAGN-A-PAK TM Power Modules Features High current capability 3000 VRMS isolating voltage with non-toxic substrate High surge capability High voltage ratings up to 2000V Industrial standard package UL recognition pending 600 A Typical Applications Rectifying bridge for large motor drives Rectifying bridge for large UPS Major Ratings and Characteristics Parameters I F(AV) @ TC IF(RMS) @ TC IFSM I2t @ 50Hz @ 60Hz @ 50Hz @ 60Hz I2 t V RRM T STG TJ range range range IRKD600.. 600 82 1120 82 19.0 20.1 1805 1683 18050 800 to 2000 - 40 to 150 - 40 to 150 Units A C A C KA KA KA2s KA2s KA2 s V C C To Order 1 Previous Datasheet IRKD600.. Series ELECTRICAL SPECIFICATIONS Voltage Ratings Type number Voltage Code 08 IRKD600.. 12 16 20 Index Next Data Sheet VRRM , maximum repetitive peak reverse voltage V 800 1200 1600 2000 VRSM , maximum nonrepetitive peak rev. voltage V 900 1300 1700 2100 IRRM max. @ TJ max. mA 50 Forward Conduction Parameter IF(AV) IF(RMS) IFSM Maximum average forward current @ Case temperature Maximum RMS forward current Maximum peak, one-cycle forward, non-repetitive surge current IRKD600.. 600 82 1120 19.0 20.1 16.2 17.2 Units Conditions A C A KA 180 conduction, half sine wave @ T C = 82C t = 10ms t = 8.3ms t = 10ms t = 8.3ms KA2s t = 10ms t = 8.3ms t = 10ms t = 8.3ms 2 180 conduction, half sine wave No voltage reapplied 100% VRRM reapplied No voltage reapplied 100% VRRM reapplied Sinusoidal half wave, Initial TJ = TJ max. I2 t Maximum I2t for fusing 1805 1683 1319 1230 I t 2 Maximum I t for fusing 2 18050 0.70 0.77 0.28 0.25 1.24 KA s t = 0.1 to 10ms, no voltage reapplied V (16.7% x x IF(AV) < I < x IF(AV)), TJ = T J max. (I > x IF(AV)), TJ = T J max. m (16.7% x x IF(AV) < I < x IF(AV)), TJ = T J max. (I > x IF(AV)), TJ = T J max. V Ipk = 1800A, TJ = 25C, tp = 10ms sine pulse VF(TO)1 Low level value of threshold voltage VF(TO)2 High level value of threshold voltage rf1 rf2 VFM Low level value of forward slope resistance High level value of forward slope resistance Maximum forward voltage drop Blocking Parameter VINS IRRM RMS isolation voltage Maximum peak reverse and off-state leakage current IRKD600.. 3000 50 Units Conditions V mA t=1s TJ = TJ max., rated VRRM applied To Order 2 Previous Datasheet Index Next Data Sheet IRKD600.. Series Thermal and Mechanical Specifications Parameter TJ Tstg R thJC Max. junction operating temperature range Max. storage temperature range Max. thermal resistance, junction to case R thC-hs Max. thermal resistance, case to heatsink T Mounting torque 10%SMAP to heatsink busbar to SMAP wt Approximate weight Case style 6-8 12 - 15 1500 g See outline table Nm A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound IRKD600.. - 40 to 150 - 40 to 150 0.065 Units Conditions C K/W Per junction, DC operation 0.02 K/W Super Magn-a-Pak RthJC Conduction (The following table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC) Conduction angle 180 120 90 60 30 Sinusoidal conduction Rectangular conduction 0.009 0.011 0.014 0.021 0.037 0.006 0.011 0.015 0.022 0.038 Units Conditions K/W TJ = TJ max. Ordering Information Table 1 Device Code ~ IRK 1 1 2 3 4 Module type D 2 600 3 - 20 4 + 2 Circuit configuration D = 2 diodes in series Current rating Voltage code: Code x 100 = VRRM (See Voltage Ratings Table) 3 To Order 3 Previous Datasheet IRKD600.. Series Outline Table All dimensions in millimeters (inches) Index Next Data Sheet To Order 4 |
Price & Availability of IRKD600 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |