 Low Signal Relay
s s s s s
G5V-1
High sensitivity: 150 mW nominal power consumption with 96 mW pickup power Small size at 10 H x 7.5 W x 12.5 L mm (0.394 H x 0.295 W x 0.492 L in) Conforms to FCC part 68 voltage surge Fully-sealed construction Ideal for use in telecommunications, security, and computer/peripheral equipment Available in PCB through-hole, SMT gullwing; high ambient versions and high dielectric versions
s
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12). Terminal PCB through-hole Type Standard Special pickup High dielectric Standard High dielectric Contact form SPDT Contact type Single crossbar Construction Fully sealed Part number G5V-1 G5V-1-2 G5V-1-HTY G5V-1F G5V-1F-Y
Surface mount gullwing
Note: Reflow solder process version is also available in PCB through-hole configuration. Please consult your local Omron sales representative for more information.
Specifications
s CONTACT DATA
Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (p.f. = 1) 0.50 A at 125 VAC, 1 A 24 VDC Ag (Au clad) 2A 125 VAC, 60 VDC 1A 62.50 VA, 30W 1 mA, 5 VDC Inductive load (p.f. = 0.4, L/R = 7ms)
G5V-1
s COIL DATA (G5V-1, G5V-1-2)
Rated voltage (VDC) 3 5 6 9 12 24 Rated current (mA) 50 30 25 16.70 12.50 6.30 Coil resistance () 60 166.70 240 540 960 3,840 Coil inductance (Ref. value) (H) Armature OFF 0.11 0.29 0.41 0.93 1.63 6.61 Armature ON 0.05 0.15 0.20 0.45 0.85 3.48 Pick-up voltage 80% 70% (special pickup) Dropout voltage 10% min. Maximum voltage 200% at 55C (131F) 160% at 70C (158F)
G5V-1
% of rated voltage
Power consumption (mW) Approx. 150
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10% . 2. The operating characteristics are measured at a coil temperature of 23C (73F).
s COIL DATA (G5V-1-HTY, G5V-1F, G5V-1F-Y)
Rated voltage (VDC) 5 12 24 Rated current (mA) 30 12.50 8.3 Coil resistance () 166.70 960 2,880 Coil inductance (Ref. value) (H) Armature OFF 0.29 1.63 4.95 Armature ON 0.15 0.85 2.61 Pick-up voltage 80% max. Dropout voltage 10% min. Maximum voltage 200% at 55C (131F) 160% at 70C (158F) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10% . 2. The operating characteristics are measured at a coil temperature of 23C (73F). Power consumption (mW) Approx. 150 Approx. 200
% of rated voltage
s CHARACTERISTICS
Contact resistance Operate time Release time Bounce time Operating frequency Insulation resistance Dielectric strength 100 m max. 5 ms max. (mean value: approx. 2.50 ms) 5 ms max. (mean value: approx. 0.90 ms) 5 ms max. (mean value: approx. 0.17 ms) 36,000 operations/hour 1,800 operations/hour 1,000 M min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,500 VAC, 50/60 Hz for 1 minute between coil and contacts (high dielectric versions) 400 VAC, 50/60 Hz for 1 minute between contacts of same polarity 1,500 V 10 X 160 s (conforms to FCC Part 68) 10 to 55 Hz, 3.30 mm (0.13 in) double amplitude 1,000 m/s2 (approx. 100 G) 100 m/s2 (approx. 10 G) -30C to 70C (-22F to 158F) for standard and special pickup PCB through-hole version; -40C to 70C (-40F to 158F) for surface mount versions 35% to 85% RH 5 million operations min. (at 36,000 operations/hour) See "Characteristic Data" 2.20 g (0.08 oz)
Mechanical Electrical
Surge withstand voltage Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Humidity Service life Weight Note: Data shown are of initial value.
Mechanical Electrical
2
G5V-1
s CHARACTERISTIC DATA
Maximum switching capacity Ambient temperature vs. maximum voltage (reference only) Electrical service life
G5V-1
Rated operating current (A)
Rated operating voltage (V)
Ambient temperature (C)
Service life (x104 operations)
Maximum voltage (%)
Rated operating current (A)
Dimensions
Unit: mm (inch)
s RELAYS
G5V-1, G5V-1-2
7.5 (0.30) max.
Terminal arrangement/ Internal connections (bottom view)
2.54 (0.10)
Mounting holes (bottom view)
2.54 (0.10) Six 1 (0.04) dia. holes 1.11 (0.04) 5.08 0.10 (0.20 0.004)
12.5 (0.49) max. 10 0.50 (0.39) (0.20) max. 3.5 (0.14) 0.50 (0.20)
Mounting mark Mounting mark 1.07 (0.04)
10.16 0.10 (0.40 0.004)
1.11 (0.04) 1.07 (0.04)
G5V-1-HTY
Terminal arrangement/ Internal connections (bottom view)
13 (0.51) max. 8 (0.31) max. 1.07 (0.04) Mounting mark
Mounting holes (bottom view)
10.16 0.1 (0.40 0.003) 2.54 (0.10) 2.54 (0.10)
9 0.5 (0.35)(0.02) max. Mounting mark 0.5 (0.02) 3.5 (0.14) 0.3 (0.01)
5.08 0.1 (0.20 0.004)
6-1 dia. holes
1.11 (0.04)
3
G5V-1
G5V-1F, G5V-1F-Y Terminal arrangement/ Internal connections (top view)
8 (0.31) max. 10 (0.39) max. 0.5 (0.02) 10.16 (0.40) 1.5 (0.06)
5.08 (0.20)
G5V-1
Mounting pads (top view)
2.54 (0.10) 1 (0.04) 10.16 (0.40)
13 (0.51) max.
7 (0.28) Mounting mark
2.54 (0.10)
9.5 (0.37) max. 3.5 (0.14)
Note: 1. and indicate mounting orientation marks. 2. A tolerance of 0.10 (0.004) applies to the above dimensions.
s REEL DIMENSIONS (FOR SURFACE MOUNT VERSIONS ONLY)
Unit: mm (inch)
2 0.3 (0.08)
21 0.5 (0.83)
R1.0
13 0.2 (0.51)
Tape
4 0.1 (0.16) 2 0.1 (0.08) 1.75 0.1 (0.07) 10.1 0.1 (0.40) 0.4 0.05 (0.02)
1.5 0.1 (0.06)
4
654321 654321 654321
29.5 1.0 (1.16) 25.5 0.5 (1.00) Top tape (cover tape)
330 (12.99)
80 (3.15)
Emboss Carrier tape
Feeding direction 24 0.1 (0.94)
13.4 0.1 (0.53)
16 0.1 (0.63)
11.5 0.1 (0.45)
9.8 0.1 (0.39)
G5V-1
s APPROVALS
UL (File No. E41515)/CSA (File No. LR24825) Type G5V-1 G5V-1-2 G5V-1F G5V-1F-Y G5V-1-HTY Contact form SPDT Coil rating 3 to 24 VDC Contact ratings 0.5 A, 125 VAC 0.3 A, 60 VDC 1.0 A, 30 VDC
G5V-1
Note: 1. In the interest of product improvement, specifications are subject to change. 2. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings).
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
One East Commerce Drive Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue Scarborough, Ontario M1B 5V8
1-800-55-OMRON
Cat. No. GC RLY7 1/00 Specifications subject to change without notice.
416-286-6465
Printed in the U.S.A.
5