Part Number Hot Search : 
000AE BLF571 2C160A HS2KA KSV2113 2464D 6152A30 N4948
Product Description
Full Text Search
 

To Download LA25-NPSP14 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Current Transducer LA 25-NP/SP14
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
0.25 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd Vb @ 0.25 A max @ 0.36 A max 0.25 0 .. 0.36 R M min R M max 100 100 320 190 A A mA V mA kV V V
Features
*Closed loop (compensated) multiturns current transducer using the Hall effect *Insulated plastic case recognized according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. rated voltage 1), safe separation basic isolation
25 100 : 1000 15 10 + IS 2.5 600 1700
Special features
*IPN *IP *K N *TA
= = = = 0.25 A 0 .. 0.36 A 100 : 1000 - 10C .. + 70C.
Accuracy - Dynamic performance data
X
Advantages
0.5 < 0.2 % % mA mA mA s kHz
L
Typical accuracy @ IPN , TA = 25C Linearity
IO IOM IOT tr f
Typ Max Offset current 2) @ IP = 0, TA = 25C 0.05 0.15 Residual current 3) @ IP = 0, after an overload of 3 x IPN 0.05 0.15 Thermal drift of IO - 10C .. + 70C 0.10 0.35 Response time 4) @ 90 % of IP max Frequency bandwidth (- 1 dB) <1 DC .. 150
*Excellent accuracy *Very good linearity *Low temperature drift *Optimized response time *Wide frequency bandwidth *No insertion losses *High immunity to external
interference
*Current overload capability.
General data
TA TS RP RS LP R IS m Ambient operating temperature Ambient storage temperature Primary coil resistance @ TA = 25C Secondary coil resistance @ TA = 70C Primary insertion inductance Isolation resistance @ 500 V, TA = 25C Mass Standards 5) - 10 .. + 70 - 25 .. + 85 < 745 110 496 > 1500 22 EN 50178 C C m H M g
Applications
*AC variable speed drives and servo
motor drives
*Static converters for DC motor drives *Battery supplied applications *Uninterruptible Power Supplies
(UPS)
*Switched Mode Power Supplies
(SMPS)
*Power supplies for welding
Notes :
1) 2) 3) 4) 5)
Pollution class 2 Measurement carried out after 15 mn functionning The result of the coercive field of the magnetic circuit With a di/dt of 100 A/s A list of corresponding tests is available
applications.
990126/2
LEM Components
w w w .lem.com
Dimensions LA 25-NP/SP14
Bottom view
(in mm. 1 mm = 0.0394 inch)
Right view
Top view
swiss made
Standard 00 or N SP..
Year
Week
Secondary terminals
Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V
Connection
in out
Back view Mechanical characteristics
*General tolerance *Fastening & connection of primary
0.2 mm 2 pins 0.635 x 0.635 mm *Fastening & connection of secondary 3 pins 1 mm *Recommended PCB hole 1.2 mm
Remark
*IS is positive when IP flows from terminal + to terminal -.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.


▲Up To Search▲   

 