APT30M70BVFR 300V 48A 0.070 POWER MOS V (R) FREDFET TO-247 Power MOS V(R) is a new generation of high voltage N-Channel enhancement mode power MOSFETs. This new technology minimizes the JFET effect, increases packing density and reduces the on-resistance. Power MOS V(R) also achieves faster switching speeds through optimized gate layout. * Fast Recovery Body Diode * Lower Leakage * Faster Switching MAXIMUM RATINGS Symbol VDSS ID IDM VGS VGSM PD TJ,TSTG TL IAR EAR EAS Parameter Drain-Source Voltage * 100% Avalanche Tested FREDFET D G S * Popular TO-247 Package All Ratings: TC = 25C unless otherwise specified. APT30M70BVFR UNIT Volts Amps 300 48 192 30 40 370 2.96 -55 to 150 300 48 30 4 1 Continuous Drain Current @ TC = 25C Pulsed Drain Current Gate-Source Voltage Continuous Gate-Source Voltage Transient Total Power Dissipation @ TC = 25C Linear Derating Factor Operating and Storage Junction Temperature Range Lead Temperature: 0.063" from Case for 10 Sec. Avalanche Current 1 Volts Watts W/C C Amps mJ (Repetitive and Non-Repetitive) 1 Repetitive Avalanche Energy Single Pulse Avalanche Energy 1300 STATIC ELECTRICAL CHARACTERISTICS Symbol BVDSS ID(on) RDS(on) IDSS IGSS VGS(th) Characteristic / Test Conditions Drain-Source Breakdown Voltage (VGS = 0V, ID = 250A) On State Drain Current 2 MIN TYP MAX UNIT Volts Amps 300 48 0.070 250 1000 100 2 4 (VDS > I D(on) x R DS(on) Max, VGS = 10V) 2 Drain-Source On-State Resistance (VGS = 10V, 0.5 ID[Cont.]) Ohms A nA Volts 050-5548 Rev A Zero Gate Voltage Drain Current (VDS = VDSS, VGS = 0V) Zero Gate Voltage Drain Current (VDS = 0.8 VDSS, VGS = 0V, TC = 125C) Gate-Source Leakage Current (VGS = 30V, VDS = 0V) Gate Threshold Voltage (VDS = VGS, ID = 1.0mA) APT Website - http://www.advancedpower.com Bend, Oregon 97702-1035 F-33700 Merignac - France Phone: (541) 382-8028 Phone: (33) 5 57 92 15 15 CAUTION: These Devices are Sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed. USA 405 S.W. Columbia Street FAX: (541) 388-0364 FAX: (33) 5 56 47 97 61 EUROPE Avenue J.F. Kennedy Bat B4 Parc Cadera Nord DYNAMIC CHARACTERISTICS Symbol Ciss Coss Crss Qg Qgs Qgd t d(on) tr t d(off) tf Characteristic Input Capacitance Output Capacitance Reverse Transfer Capacitance Total Gate Charge 3 APT30M70BVFR Test Conditions VGS = 0V VDS = 25V f = 1 MHz VGS = 10V VDD = 0.5 VDSS ID = ID [Cont.] @ 25C VGS = 15V VDD = 0.5 VDSS ID = ID [Cont.] @ 25C RG = 1.6 MIN TYP MAX UNIT pF 4890 882 277 152 35 66 14 21 57 10 5870 1235 415 225 52 99 28 42 85 20 ns nC Gate-Source Charge Gate-Drain ("Miller") Charge Turn-on Delay Time Rise Time Turn-off Delay Time Fall Time SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS Symbol IS ISM VSD dv/ dt Characteristic / Test Conditions Continuous Source Current (Body Diode) Pulsed Source Current Diode Forward Voltage 1 2 MIN TYP MAX UNIT Amps Volts V/ns ns C Amps 48 192 1.3 5 Tj = 25C Tj = 125C Tj = 25C Tj = 125C Tj = 25C Tj = 125C (Body Diode) (VGS = 0V, IS = -ID [Cont.]) 5 Peak Diode Recovery dv/dt t rr Q rr IRRM Reverse Recovery Time (IS = -ID [Cont.], di/dt = 100A/s) Reverse Recovery Charge (IS = -ID [Cont.], di/dt = 100A/s) Peak Recovery Current (IS = -ID [Cont.], di/dt = 100A/s) 225 400 1.0 4.2 10 20 THERMAL CHARACTERISTICS Symbol RJC RJA Characteristic Junction to Case Junction to Ambient MIN TYP MAX UNIT C/W 0.34 40 1 Repetitive Rating: Pulse width limited by maximum junction temperature. 2 Pulse Test: Pulse width < 380 S, Duty Cycle < 2% 3 See MIL-STD-750 Method 3471 4 Starting T = +25C, L = 1.13mH, R = 25, Peak I = 48A j G L 5 I -I [Cont.], di/ = 100A/s, V S D DD VDSS, Tj 150C, RG = 2.0, dt VR = 200V. APT Reserves the right to change, without notice, the specifications and information contained herein. 0.4 , THERMAL IMPEDANCE (C/W) D=0.5 0.1 0.05 0.2 0.1 0.05 PDM 0.01 0.005 0.02 0.01 Note: t1 t2 JC 050-5548 Rev A Z SINGLE PULSE 0.001 10-5 Duty Factor D = t1/t2 Peak TJ = PDM x ZJC + TC 10-3 10-2 10-1 1.0 10 RECTANGULAR PULSE DURATION (SECONDS) FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION 10-4 APT30M70BVFR 100 VGS=7V, 10V & 15V ID, DRAIN CURRENT (AMPERES) 6V 80 ID, DRAIN CURRENT (AMPERES) 80 100 VGS=15V VGS=10V VGS=7V 5.5V 6V 60 5.5V 60 40 5V 40 5V 20 4.5V 4V 20 4.5V 4V 0 30 60 90 120 150 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 2, TYPICAL OUTPUT CHARACTERISTICS RDS(ON), DRAIN-TO-SOURCE ON RESISTANCE 100 TJ = -55C ID, DRAIN CURRENT (AMPERES) 80 TJ = +25C TJ = +125C VDS> ID (ON) x RDS (ON)MAX. 250SEC. PULSE TEST @ <0.5 % DUTY CYCLE 0 0 2 4 6 8 10 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 3, TYPICAL OUTPUT CHARACTERISTICS 1.3 V GS 0 NORMALIZED TO = 10V @ 0.5 I [Cont.] D 1.2 60 1.1 VGS=10V VGS=20V 1.0 40 TJ = +125C TJ = +25C 0 TJ = -55C 20 0 2 4 6 8 VGS, GATE-TO-SOURCE VOLTAGE (VOLTS) FIGURE 4, TYPICAL TRANSFER CHARACTERISTICS 50 ID, DRAIN CURRENT (AMPERES) 0.9 0 20 40 60 80 100 ID, DRAIN CURRENT (AMPERES) FIGURE 5, RDS(ON) vs DRAIN CURRENT BVDSS, DRAIN-TO-SOURCE BREAKDOWN VOLTAGE (NORMALIZED) 25 I = 0.5 I [Cont.] D D 1.20 1.15 1.10 1.05 1.00 0.95 40 30 20 10 50 75 100 125 150 TC, CASE TEMPERATURE (C) FIGURE 6, MAXIMUM DRAIN CURRENT vs CASE TEMPERATURE RDS(ON), DRAIN-TO-SOURCE ON RESISTANCE (NORMALIZED) 2.5 VGS(TH), THRESHOLD VOLTAGE (NORMALIZED) V GS 0 -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (C) FIGURE 7, BREAKDOWN VOLTAGE vs TEMPERATURE 1.2 0.90 -50 = 10V 2.0 1.1 1.0 0.9 0.8 0.7 050-5548 Rev A 1.5 1.0 0.5 0.0 -50 -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (C) FIGURE 8, ON-RESISTANCE vs. TEMPERATURE -25 0 25 50 75 100 125 150 TC, CASE TEMPERATURE (C) FIGURE 9, THRESHOLD VOLTAGE vs TEMPERATURE 0.6 -50 APT30M70BVFR 200 100 ID, DRAIN CURRENT (AMPERES) 50 1mS 10 5 10mS 100mS DC TC =+25C TJ =+150C SINGLE PULSE C, CAPACITANCE (pF) 5,000 OPERATION HERE LIMITED BY RDS (ON) 10S 100S 15,000 10,000 Ciss Coss 1,000 500 Crss 1 .5 .1 1 5 10 50 100 300 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 10, MAXIMUM SAFE OPERATING AREA I = I [Cont.] D D .01 .1 1 10 50 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 11, TYPICAL CAPACITANCE vs DRAIN-TO-SOURCE VOLTAGE IDR, REVERSE DRAIN CURRENT (AMPERES) 200 100 50 TJ =+150C TJ =+25C 100 VGS, GATE-TO-SOURCE VOLTAGE (VOLTS) 20 VDS=60V VDS=150V 12 VDS=240V 8 16 10 5 1 .5 4 50 100 150 200 250 300 Qg, TOTAL GATE CHARGE (nC) FIGURE 12, GATE CHARGES vs GATE-TO-SOURCE VOLTAGE 0 0 0 0.4 0.8 1.2 1.6 2.0 VSD, SOURCE-TO-DRAIN VOLTAGE (VOLTS) FIGURE 13, TYPICAL SOURCE-DRAIN DIODE FORWARD VOLTAGE .1 TO-247 Package Outline 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) 6.15 (.242) BSC 15.49 (.610) 16.26 (.640) 5.38 (.212) 6.20 (.244) Drain 20.80 (.819) 21.46 (.845) 3.50 (.138) 3.81 (.150) 4.50 (.177) Max. 0.40 (.016) 0.79 (.031) 2.87 (.113) 3.12 (.123) 1.65 (.065) 2.13 (.084) 19.81 (.780) 20.32 (.800) 1.01 (.040) 1.40 (.055) Gate Drain Source 2.21 (.087) 2.59 (.102) 050-5548 Rev A 5.45 (.215) BSC 2-Plcs. Dimensions in Millimeters and (Inches) APT's devices are covered by one or more of the following U.S.patents: 4,895,810 5,256,583 5,045,903 4,748,103 5,089,434 5,283,202 5,182,234 5,231,474 5,019,522 5,434,095 5,262,336 5,528,058 |
Price & Availability of APT30M70BVFR
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |