MOS FET Relays New MOS FET Relay with Low Output Capacitance and ON Resistance (CR = 5pF* W) in a 20-V Load Voltage Model * ON resistance of 1 W (typical) suppresses output signal attenuation. * Leakage current of 1.0 nA max. when output relay is open. G3VM-21GR1 Application Examples * Semiconductor inspection tools * Measurement devices * Broadband systems * Data loggers Note: The actual product is marked differently from the image shown here. List of Models Contact form SPST-NO Terminals Surface-mounting terminals Load voltage (peak value) 20 VAC Model G3VM-21GR1 G3VM-21GR1(TR) Number per stick 100 --2,500 Number per tape Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-21GR1 4.40.25 3.90.2 2.1 max. 0.15 Note: The actual product is marked differently from the image shown here. 0.40.1 2.540.25 0.10.1 0.60.3 7.00.4 Weight: 0.1 g Terminal Arrangement/Internal Connections (Top View) G3VM-21GR1 4 3 1 2 Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-21GR1 6 to 6.3 1.2 0.8 2.54 50 G3VM-21GR1 Absolute Maximum Ratings (Ta = 25C) Item Input LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Output Output dielectric strength Continuous load current ON current reduction rate Connection temperature Dielectric strength between input and output (See note 1.) Operating temperature Storage temperature Soldering temperature (10 s) Symbol IF IFP D IF/C VR Tj VOFF IO D ION/C Tj VI-O Ta Tstg --Rating 50 1 -0.5 5 125 20 300 -3.0 125 1,500 -20 to +85 -55 to +125 260 Unit mA A mA/C V C V mA mA/C C Vrms C C C AC for 1 min With no icing or condensation With no icing or condensation 10 s Ta 25C 100 ms pulses, 100 pps Ta 25C Measurement Conditions G3VM-21GR1 Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25C) Item Input LED forward voltage Reverse current Capacity between terminals Trigger LED forward current Output Maximum resistance with output ON Current leakage when the relay is open Capacity between terminals Capacity between I/O terminals Insulation resistance Turn-ON time Turn-OFF time Symbol VF IR CT IFT RON ILEAK COFF CI-O RI-O tON tOFF Minimum 1.0 --------------1,000 ----Typical 1.15 --15 --1 --5.0 0.8 ------Maximum 1.3 10 --4 1.5 1.0 12.0 ----0.5 0.5 V mA pF mA W nA pF pF MW ms ms Unit Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz IO = 100 mA IF = 5 mA, IO = 300 mA, t < 1 s VOFF = 20 V Ta = 50C V = 0, f = 100 MHz, t<1s f = 1 MHz, Vs = 0 V VI-O = 500 VDC, RoH 60% IF = 10 mA, RL = 200 W, VDD = 20 V (See note 2.) VOUT IF Note: 2. Turn-ON and Turn-OFF Times IF 1 2 4 3 RL VDD VOUT 10% tON 90% tOFF Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Output dielectric strength Operating LED forward current Continuous load current Operating temperature Symbol VDD IF IO Ta --7 --25 Minimum --------Typical 20 30 300 60 Maximum V mA mA C Unit Engineering Data Load Current vs. Ambient Temperature G3VM-21GR1 Load current (mA) 400 350 300 250 200 150 100 50 0 -20 Safety Precautions Refer to page 6 for precautions common to all G3VM models. 0 20 40 60 80 100 Ambient temperature (C) 51 |
Price & Availability of G3VM-21GR1 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |