![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Current Transducer LT 10000-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 10000 A Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range (1 s / mn) Measuring resistance with 48 V with 60 V ISN KN VC IC Vd @ 10000 A max @ 12000 A max @ 10000 A max @ 15000 A max 10000 0 .. 15000 RM min RM max 0 0 0 0 8 1 20 1.5 A A Features *Closed loop (compensated) current transducer using the Hall effect *Insulated case. Advantages *Excellent accuracy *Very good linearity *Low temperature drift *Optimized response time *Wide frequency bandwidth *No insertion losses *High immunity to external interference Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 1 A 1 : 10000 48 .. 60 V 40 (@ 60 V) + IS mA 10 1) kV 1 2) kV Accuracy - Dynamic performance data XG *Current overload capability. 0.3 < 0.1 Typ Max 1.5 0.8 % % mA mA s A/s kHz L Overall accuracy @ IPN , TA = 25C Linearity Offset current @ IP = 0, TA = 25C Thermal drift of IO - 25C .. + 70C Response time 3) @ 90 % of IP max di/dt accurately followed Frequency bandwidth (- 1 dB) Applications *AC variable speed drives and servo motor drives IO IOT tr di/dt f 0.6 <1 > 50 DC .. 100 *Static converters for DC motor drives *Battery supplied applications *Uninterruptible Power Supplies (UPS) *Switched Mode Power Supplies General data TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70C Mass Standards 4) - 25 .. + 70 - 40 .. + 85 35 17 EN 50178 C C kg (SMPS) *Power supplies for welding applications. Notes : 1) 2) 3) 4) Between primary and secondary + shield Between secondary and shield With a di/dt of 100 A/s A list of corresponding tests is available 980708/6 LEM Components w w w .lem.com Dimensions LT 10000-S Front view (in mm. 1 mm = 0.0394 inch) Left view Secondary terminals Terminal + : supply voltage + 48 .. 60 V Terminal M : measure Terminal 0 V : 0 V Terminal - : supply voltage - 48 .. 60 V Terminal E : shield Connection or Mechanical characteristics *General tolerance *Fastening *Primary through-hole *Connection of secondary Fastening torque 1 mm 4 holes 11 mm 200 mm M5 threaded studs 2.2 Nm or 1.62 Lb - Ft Remarks *IS is positive when IP flows in the direction of the arrow. *Temperature of the primary conductor should not exceed 100C. *Dynamic performances (di/dt and response time) are best with a primary bar in the center of the through-hole. *This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Price & Availability of LT10000-S
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |