![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ICX419AKB Diagonal 8mm (Type 1/2) CCD Image Sensor for PAL Color Video Cameras Description The ICX419AKB is an interline CCD solid-state image sensor suitable for PAL color video cameras with a diagonal 8mm (Type 1/2) system. Compared with the current product ICX039DNB, basic characteristics such as sensitivity, smear, dynamic range and S/N are improved drastically. This chip features a field period readout system and an electronic shutter with variable charge-storage time. Also, this outline is miniaturized by using original package. This chip is compatible with the pins of the ICX039DNB and has the same drive conditions. 16 pin DIP (Ceramic) Pin 1 2 V Features * High sensitivity (+6.0dB compared with the ICX039DNB) * Low smear (-5.0dB compared with the ICX039DNB) 3 * High D range (+3.0dB compared with the ICX039DNB) 40 H Pin 9 * High S/N * High resolution and low dark current Optical black position * Excellent antiblooming characteristics (Top View) * Ye, Cy, Mg, and G complementary color mosaic filters on chip * Continuous variable-speed shutter * Substrate bias: Adjustment free (external adjustment also possible with 6 to 14V) * Reset gate pulse: 5Vp-p adjustment free (drive also possible with 0 to 9V) * Horizontal register: 5V drive * Maximum package dimensions: 13.2mm 12 Device Structure * Interline CCD image sensor * Optical size: Diagonal 8mm (Type 1/2) * Number of effective pixels: 752 (H) x 582 (V) approx. 440K pixels * Total number of pixels: 795 (H) x 596 (V) approx. 470K pixels * Chip size: 7.40mm (H) x 5.95mm (V) * Unit cell size: 8.6m (H) x 8.3m (V) * Optical black: Horizontal (H) direction: Front 3 pixels, rear 40 pixels Vertical (V) direction: Front 12 pixels, rear 2 pixels * Number of dummy bits: Horizontal 22 Vertical 1 (even fields only) * Substrate material: Silicon Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits. -1- E01911 ICX419AKB Block Diagram and Pin Configuration (Top View) VOUT SUB VDD V1 V2 V3 V4 1 Note) 8 7 6 VL 5 4 3 2 Cy Ye G Ye G Ye G Cy Mg Ye G Ye G Ye G Vertical Register Mg Cy Mg Cy Mg Cy Mg Cy Mg Horizontal Register Note) 9 10 11 12 13 14 15 16 : Photo sensor VDSUB GND H1 Pin Description Pin No. Symbol 1 2 3 4 5 6 7 8 V4 V3 V2 SUB V1 VL VDD VOUT Description Vertical register transfer clock Vertical register transfer clock Vertical register transfer clock Substrate clock Vertical register transfer clock Protective transistor bias Output circuit supply voltage Signal output Pin No. Symbol 9 10 11 12 13 14 15 16 NC NC GND RD RG VDSUB H1 H2 GND Reset drain bias Reset gate clock Substrate bias circuit supply voltage Horizontal register transfer clock Horizontal register transfer clock Description -2- H2 NC NC RG RD ICX419AKB Absolute Maximum Ratings Item Substrate clock SUB - GND Supply voltage Clock input voltage VDD, VRD, VDSUB, VOUT - GND VDD, VRD, VDSUB, VOUT - SUB V1, V2, V3, V4 - GND V1, V2, V3, V4 - SUB Ratings -0.3 to +50 -0.3 to +18 -55 to +10 -15 to +20 to +10 to +15 to +17 -17 to +17 -10 to +15 -55 to +10 -65 to +0.3 -0.3 to +30 -30 to +80 -10 to +60 Unit V V V V V V V V V V V V C C 1 Remarks Voltage difference between vertical clock input pins Voltage difference between horizontal clock input pins H1, H2 - V4 RG - GND RG - SUB VL - SUB Pins other than GND and SUB - VL Storage temperature Operating temperature 1 +27V (Max.) when clock width < 10s, clock duty factor < 0.1%. -3- ICX419AKB Bias Conditions 1 [when used in substrate bias internal generation mode] Item Output circuit supply voltage Reset drain voltage Protective transistor bias Substrate bias circuit supply voltage Substrate clock Symbol VDD VRD VL VDSUB SUB 14.55 Min. 14.55 14.55 Typ. 15.0 15.0 1 15.0 2 15.45 V Max. 15.45 15.45 Unit V V VRD = VDD Remarks 1 VL setting is the VVL voltage of the vertical transfer clock waveform, or the same supply voltage as the VL power supply for the V driver should be used. (When CXD1267AN is used.) 2 Do not apply a DC bias to the substrate clock pin, because a DC bias is generated within the CCD. Bias Conditions 2 [when used in substrate bias external adjustment mode] Item Output circuit supply voltage Reset drain voltage Protective transistor bias Substrate bias circuit supply voltage Substrate voltage adjustment range Substrate voltage adjustment precision Symbol VDD VRD VL VDSUB VSUB VSUB 6.0 -3 Min. 14.55 14.55 Typ. 15.0 15.0 3 4 14.0 +3 V % 5 5 Max. 15.45 15.45 Unit V V VRD = VDD Remarks 3 VL setting is the VVL voltage of the vertical transfer clock waveform, or the same supply voltage as the VL power supply for the V driver should be used. (When CXD1267AN is used.) 4 Connect to GND or leave open. 5 The setting value of the substrate voltage (VSUB) is indicated on the back of the image sensor by a special code. When adjusting the substrate voltage externally, adjust the substrate voltage to the indicated voltage. The adjustment precision is 3%. However, this setting value has not significance when used in substrate bias internal generation mode. VSUB code -- one character indication Code and optimal setting correspond to each other as follows. VSUB code E f 6.5 G 7.0 h 7.5 J 8.0 K 8.5 L 9.0 m N P Q R S T U V W Optimal setting 6.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 -4- ICX419AKB Clock Voltage Conditions Item Readout clock voltage Symbol VVT VVH1, VVH2 VVH3, VVH4 VVL1, VVL2, VVL3, VVL4 VV Vertical transfer clock voltage | VVH1 - VVH2 | VVH3 - VVH VVH4 - VVH VVHH VVHL VVLH VVLL Horizontal transfer clock voltage Reset gate clock voltage1 VH VHL VRGL VRG VRGLH - VRGLL Substrate clock voltage VSUB 4.5 4.75 -0.05 5.0 0 1 5.0 -0.25 -0.25 Min. Typ. Max. Unit V V V V Waveform diagram 1 2 2 2 2 2 2 2 2 2 2 2 3 3 4 4 4 5 Low-level coupling High-level coupling High-level coupling Low-level coupling Low-level coupling VVL = (VVL3 + VVL4)/2 VV = VVHn - VVLn (n = 1 to 4) VVH = (VVH1 + VVH2)/2 Remarks 14.55 15.0 15.45 -0.05 -0.2 0 0 0.05 0.05 -9.6 -9.0 -8.5 8.3 9.0 9.65 Vp-p 0.1 0.1 0.1 0.5 0.5 0.5 0.5 0.05 V V V V V V V V V 5.5 Vp-p 0.8 V 5.25 Vp-p 23.0 24.0 25.0 Vp-p 1 Input the reset gate clock without applying a DC bias. In addition, the reset gate clock can also be driven with the following specifications. Item Reset gate clock voltage Symbol VRGL VRG Min. -0.2 8.5 Typ. Max. Unit 0 9.0 0.2 V Waveform diagram 4 4 Remarks 9.5 Vp-p -5- ICX419AKB Clock Equivalent Circuit Constant Item Capacitance between vertical transfer clock and GND Capacitance between vertical transfer clocks Symbol CV1, CV3 CV2, CV4 CV12, CV34 CV23, CV41 Min. Typ. 3300 3300 820 330 120 91 47 11 680 75 82 68 Max. Unit pF pF pF pF pF pF pF pF pF Remarks Capacitance between horizontal transfer clock CH1 and GND CH2 Capacitance between horizontal transfer clocks Capacitance between reset gate clock and GND Capacitance between substrate clock and GND Vertical transfer clock series resistor Vertical transfer clock ground resistor CHH CRG CSUB R1, R3 R2, R4 RGND V1 CV12 V2 R1 R2 H1 H2 CHH CV1 CV41 CV2 CV23 CH1 CH2 CV4 R4 RGND CV34 CV3 R3 V4 V3 Vertical transfer clock equivalent circuit Horizontal transfer clock equivalent circuit -6- ICX419AKB Drive Clock Waveform Conditions (1) Readout clock waveform 100% 90% VVT M M 2 10% 0% tr twh tf 0V (2) Vertical transfer clock waveform V1 VVH1 VVHH VVH VVHL VVHL VVHH VVHL VVH3 V3 VVHH VVH VVHH VVHL VVL1 VVLH VVL3 VVLH VVLL VVL VVLL VVL V2 V4 VVHH VVHH VVH VVHL VVH VVHH VVHH VVH2 VVHL VVHL VVH4 VVHL VVL2VVLH VVLL VVL4 VVLH VVLL VVL VVL VVH = (VVH1 + VVH2)/2 VVL = (VVL3 + VVL4)/2 VV = VVHn - VVLn (n = 1 to 4) -7- ICX419AKB (3) Horizontal transfer clock waveform tr twh tf 90% VH 10% VHL twl (4) Reset gate clock waveform tr twh tf VRGH twl VRG VRGL + 0.5V VRGL VRGLL VRGLm H1 waveform +2.5V Point A RG waveform VRGLH VRGLH is the maximum value and VRGLL is the minimum value of the coupling waveform during the period from Point A in the above diagram until the rising edge of RG. In addition, VRGL is the average value of VRGLH and VRGLL. VRGL = (VRGLH + VRGLL)/2 Assuming VRGH is the minimum value during the period twh, then: VRG = VRGH - VRGL Negative overshoot level during the falling edge of RG is VRGLm. (5) Substrate clock waveform 100% 90% M VSUB 10% VSUB 0% tr twh tf M 2 -8- ICX419AKB Clock Switching Characteristics Item Readout clock Vertical transfer clock Horizontal transfer clock Symbol VT V1, V2, V3, V4 H twh 2.3 2.5 twl 0.5 tr 0.5 15 tf Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Remarks s During readout 250 ns 1 15 0.01 s 0.01 3 ns 0.5 s During drain charge 19 ns 2 During imaging 20 5.38 20 15 0.01 19 During H1 parallel-serial H2 conversion 11 5.38 13 51 0.01 3 0.5 Reset gate clock RG Substrate clock SUB 1.5 1.8 1 When vertical transfer clock driver CXD1267AN is used. 2 tf tr - 2ns. Item Horizontal transfer clock Symbol H1, H2 two Min. 16 Typ. 20 Max. Unit Remarks ns 3 3 The overlap period for twh and twl of horizontal transfer clocks H1 and H2 is two. -9- ICX419AKB Image Sensor Characteristics Item Sensitivity Saturation signal Smear Video signal shading Uniformity between video signal channels Dark signal Dark signal shading Flicker Y Flicker R-Y Flicker B-Y Line crawl R Line crawl G Line crawl B Line crawl W Lag Symbol S Ysat Sm SHy Sr Sb Ydt Ydt Fy Fcr Fcb Lcr Lcg Lcb Lcw Lag Min. 1040 1000 -115 -105 20 25 10 10 2 1 2 5 5 3 3 3 3 0.5 Typ. 1300 Max. Unit mV mV dB % % % % mV mV % % % % % % % % Measurement method 1 2 3 4 4 5 5 6 7 8 8 8 9 9 9 9 10 Ta = 60C Ta = 60C Zone 0 and I Zone 0 to II' Ta = 60C (Ta = 25C) Remarks Zone Definition of Video Signal Shading 752 (H) 14 14 12 H 8 V 10 H 8 582 (V) Zone 0, I Zone II, II' V 10 10 Ignored region Effective pixel region Measurement System [A] CCD signal output CCD C.D.S AMP S/H LPF2 S/H (3dB down 1MHz) [C] Chroma signal output LPF1 (3dB down 6.3MHz) [Y] Y signal output Note) Adjust the amplifier gain so that the gain between [A] and [Y], and between [A] and [C] equals 1. - 10 - ICX419AKB Image Sensor Characteristics Measurement Method Measurement conditions 1) In the following measurements, the device drive conditions are at the typical values of the bias and clock voltage conditions. (when used with substrate bias external adjustment, set the substrate voltage to the value indicated on the device.) 2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal output or chroma signal output of the measurement system. Color coding of this image sensor & Composition of luminance (Y) and chroma (color difference) signals Cy G B Cy Mg Ye Mg Ye G Cy G Cy Mg Ye A1 Mg Ye A2 G As shown in the left figure, fields are read out. The charge is mixed by pairs such as A1 and A2 in the A field. (pairs such as B in the B field) As a result, the sequence of charges output as signals from the horizontal shift register (Hreg) is, for line A1, (G + Cy), (Mg + Ye), (G + Cy), and (Mg + Ye). Hreg Color Coding Diagram These signals are processed to form the Y signal and chroma (color difference) signal. The Y signal is formed by adding adjacent signals, and the chroma signal is formed by subtracting adjacent signals. In other words, the approximation: Y = {(G + Cy) + (Mg + Ye)} x 1/2 = 1/2 {2B + 3G + 2R} is used for the Y signal, and the approximation: R - Y = {(Mg + Ye) - (G + Cy)} = {2R - G} is used for the chroma (color difference) signal. For line A2, the signals output from Hreg in sequence are (Mg + Cy), (G + Ye), (Mg + Cy), (G + Ye). The Y signal is formed from these signals as follows: Y = {(G + Ye) + (Mg + Cy)} x 1/2 = 1/2 {2B + 3G + 2R} This is balanced since it is formed in the same way as for line A1. In a like manner, the chroma (color difference) signal is approximated as follows: - (B - Y) = {(G + Ye) - (Mg + Cy)} = - {2B - G} In other words, the chroma signal can be retrieved according to the sequence of lines from R - Y and - (B - Y) in alternation. This is also true for the B field. - 11 - ICX419AKB Definition of standard imaging conditions 1) Standard imaging condition I: Use a pattern box (luminance 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter and image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the standard sensitivity testing luminous intensity. 2) Standard imaging condition II: Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles. Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted to the value indicated in each testing item by the lens diaphragm. 1. Sensitivity Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of 1/250s, measure the Y signal (Ys) at the center of the screen and substitute the value into the following formula. S = Ys x 250 [mV] 50 2. Saturation signal Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with average value of the Y signal output, 200mV, measure the minimum value of the Y signal. 3. Smear Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to 500 times the intensity with average value of the Y signal output, 200mV. When the readout clock is stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure the maximum value YSm [mV] of the Y signal output and substitute the value into the following formula. Sm = 20 x log YSm x 1 x 500 200 1 10 [dB] (1/10V method conversion value) 4. Video signal shading Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity so that the average value of the Y signal output is 200mV. Then measure the maximum (Ymax [mV]) and minimum (Ymin [mV]) values of the Y signal and substitute the values into the following formula. SHy = (Ymax - Ymin)/200 x 100 [%] 5. Uniformity between video signal channels Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then measure the maximum (Crmax, Cbmax [mV]) and minimum (Crmin, Cbmin [mV]) values of the R - Y and B - Y channels of the chroma signal and substitute the values into the following formula. Sr = | (Crmax - Crmin)/200 | x 100 [%] Sb = | (Cbmax - Cbmin)/200 | x 100 [%] 6. Dark signal Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature 60C and the device in the light-obstructed state, using the horizontal idle transfer level as a reference. - 12 - ICX419AKB 7. Dark signal shading After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the dark signal output and substitute the values into the following formula. Ydt = Ydmax - Ydmin [mV] 8. Flicker 1) Fy Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then measure the difference in the signal level between fields (Yf [mV]). Then substitute the value into the following formula. Fy = (Yf/200) x 100 [%] 2) Fcr, Fcb Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between fields of the chroma signal (Cr, Cb) as well as the average value of the chroma signal output (CAr, CAb). Substitute the values into the following formula. Fci = (Ci/CAi) x 100 [%] (i = r, b) 9. Line crawls Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference between Y signal lines for the same field (Ylw, Ylr, Ylg, Ylb [mV]). Substitute the values into the following formula. Lci = (Yli/200) x 100 [%] (i = w, r, g, b) 10. Lag Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following formula. Lag = (Ylag/200) x 100 [%] FLD V1 Light Strobe light timing Y signal output 200mV Output Ylag (lag) - 13 - Drive Circuit 1 (substrate bias internal generation mode) 15V 1 2 3 XSUB XV2 XV1 XSG1 XV3 XSG2 XV4 4 5 6 7 8 9 10 22/20V CXD1267AN 20 19 18 17 16 15 14 13 12 11 0.01 1 2 3 4 5 6 7 8 3.3/20V 22/16V 1M 3.3/16V -9V 1/35V 100k 1 ICX419 (BOTTOM VIEW) VDSUB H2 H1 RG GND RD NC 10 16 15 14 13 12 11 H1 0.01 H2 100 [A] CCD OUT 0.01 RG 3.9k NC 9 VOUT - 14 - SUB VDD V4 V3 V2 V1 VL ICX419AKB Drive Circuit 2 (substrate bias external adjustment mode) 15V 0.1 1 2 3 XSUB XV2 XV1 XSG1 XV3 XSG2 XV4 4 5 6 7 8 9 10 22/20V 1 2 3 4 5 6 7 8 CXD1267AN 20 19 18 17 16 15 14 13 12 11 3.3/20V 0.01 22/16V 1M 3.3/16V -9V 1/35V 1/35V 1/35V 270k 15k 47k 56k 100k 27k 0.1 39k 15k 0.1 SUB ICX419 (BOTTOM VIEW) VDSUB H2 H1 RG GND RD NC 10 16 H1 15 14 13 12 11 0.01 H2 100 [A] CCD OUT NC 9 VOUT VDD V4 V3 V2 V1 VL - 15 - RG ICX419AKB 0.01 3.9k ICX419AKB Spectral Sensitivity Characteristics (Excludes lens characteristics and light source characteristics) 1.0 Cy 0.8 G Ye Relative Response 0.6 0.4 Mg 0.2 0 400 450 500 550 Wave Length [nm] 600 650 700 Sensor Readout Clock Timing Chart V1 V2 Odd Field V3 V4 33.6 1.5 0.2 2.5 2.6 2.5 2.5 V1 V2 Even Field V3 V4 Unit: s - 16 - Drive Timing Chart (Vertical Sync) FLD VD BLK HD 620 625 1 2 3 4 5 310 320 V1 V2 V3 V4 CCD OUT 581 582 246 135 315 325 246 135 582 581 135 246 330 135 246 335 340 10 15 20 25 - 17 - ICX419AKB Drive Timing Chart (Horizontal Sync) HD BLK H1 H2 750 752 1 745 10 20 30 40 10 20 22 1 2 3 1 2 3 10 20 3 5 1 2 3 5 - 18 - RG V1 V2 V3 V4 SUB ICX419AKB ICX419AKB Notes on Handling 1) Static charge prevention CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following protective measures. a) Either handle bare handed or use non-chargeable gloves, clothes or material. Also use conductive shoes. b) When handling directly use an earth band. c) Install a conductive mat on the floor or working table to prevent the generation of static electricity. d) Ionized air is recommended for discharge when handling CCD image sensor. e) For the shipment of mounted substrates, use boxes treated for the prevention of static charges. 2) Soldering a) Make sure the package temperature does not exceed 80C. b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a ground 30W soldering iron and solder each pin in less than 2 seconds. For repairs and remount, cool sufficiently. c) To dismount an image sensor, do not use a solder suction equipment. When using an electric desoldering tool, use a thermal controller of the zero cross On/Off type and connect it to ground. 3) Dust and dirt protection Image sensors are packed and delivered by taking care of protecting its glass plates from harmful dust and dirt. Clean glass plates with the following operations as required, and use them. a) Perform all assembly operations in a clean room (class 1000 or less). b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized air is recommended.) c) Clean with a cotton bud and ethyl alcohol if grease stained. Be careful not to scratch the glass. d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when moving to a room with great temperature differences. e) When a protective tape is applied before shipping, just before use remove the tape applied for electrostatic protection. Do not reuse the tape. 4) Do not expose to strong light (sun rays) for long periods. For continuous using under cruel condition exceeding the normal using condition, consult our company. 5) Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or usage in such conditions. 6) CCD image sensors are precise optical equipment that should not be subject to too much mechanical shocks. - 19 - Package Outline Unit: mm 16 pin DIP (300mil) 3.29 0.3 0. 3 1.84 A B 2 3. 1 2.54 C 9 4.0 16 16 9 12.0 0.15 12.35 0.3 7.62 V 1 H 6.175 12.0 0.15 12.35 0.3 B' 1.84 1st. pin Index 1. "A" is the center of the effective image area. 2. The point "B" of the package is the horizontal reference. The point "B'" of the package is the vertical reference. 1.5 1.0 4.0 0.2 1.5 0.7 3. The bottom "C" of the package is the height reference. 4. The center of the effective image area relative to the center of the package () is (H, V) = (0, 0) 0.15mm. 5. The rotation angle of the effective image area relative to H and V is 1. ~ ~ 0.6 1.27 0.3 6. The height from the bottom "C" to the effective image area is 1.41 0.15mm. 7. The tilt of the effective image area relative to the bottom "C" is less than 60m. 8. The thickness of the cover glass is 0.75mm, and the refractive index is 1.5. PACKAGE STRUCTURE 0.3 PACKAGE MATERIAL LEAD TREATMENT Sony Corporation M Ceramic GOLD PLATING 42 ALLOY 0.90g AS-B4-01(E) Center of the package : The center is halfway between two pairs of opposite sides, as measured from "B", "B'". LEAD MATERIAL PACKAGE MASS DRAWING NUMBER 0.25 8 6.175 1.5 8 1 4.0 ~ ~ ~ - 20 - ICX419AKB |
Price & Availability of ICX419AKB
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |