Level Sensors Conductive Types VH1, VH2, A94-10 * VH1 and VH2: Hanging electrodes with Neoprene cable * A94-10: Hanging probe for (swimming) pool level control VH1 VH2 A94-10 Product Description The sensors VH1 and VH2 are hanging electrodes with Neoprene cables. The sensor A94-10 is a hanging probe for (swimming) pool level control. For use with amplifier (please refer to separate data sheets). Ordering Key Type VH 1 Type Selection Electrode isolation No Yes Ordering no. 1 electrode VH 1 VH 2 Ordering no. 2 electrodes A 94-10 Specifications Electrodes Isolation VH2 Material Housing Material VH1, VH2 A94-10 Dimensions VH1 VH2 A94-10 Connection VH1, VH2 A94-10 Environment Degree of protection Operating temperature VH1, VH2 A94-10 Storage temperature Nylon 6 Stainless steel Dimensions Nylon 6 Polyester VH 1 O 18 x 36,5 mm O 32 x 75,5 mm O 22 x 75,0 mm Cable (Neoprene), 5 m, 1 x 2.5 mm2 Cable (PVC), 5 m, 2 x 0.5 mm2 IP 67 0 to +90C (+32 to +194F) 0 to +60C (+32 to +140 F) -25 to +100C (-13 to +212F) VH 2 A94-10 Specifications are subject to change without notice (25.06.99) 1 |