![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
2214 20-TAP DIP DELAY LINE TD/TR = 10 (SERIES 2214) FEATURES * * * * * 20 taps of equal delay increment High bandwidth (TD/TR =10) Low profile Epoxy encapsulated Meets or exceeds MIL-D-23859C N/C IN T1 T2 T3 T4 T5 T6 T7 T8 T9 GND 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 N/C T20 T19 T18 T17 T16 T15 T14 T13 T12 T11 T10 data 3 (R) delay devices, inc. PACKAGES 2214-xxz (DIP) 2214-xxzC4 (Gull-Wing) xx = Delay (TD) z = Impedance Code PIN DESCRIPTIONS IN Signal Input T1-T20 Tap Outputs GND Ground FUNCTIONAL DESCRIPTION The 2214-series device is a fixed, single-input, twenty-output, passive delay line. The signal input (IN) is reproduced at the outputs (T1-T20) in equal increments. The delay from IN to T20 (TD) is given by the device dash number. The characteristic impedance of the line is given by the letter code that follows the dash number (See Table). The rise time (TR) of the line is 10% of TD, and the 3dB bandwidth is given by 3.5 / TD. SERIES SPECIFICATIONS * * * * * Dielectric breakdown: Distortion @ output: Operating temperature: Storage temperature: Temperature coefficient: 50 Vdc 10% max. -55C to +125C -55C to +125C 100 PPM/C DASH NUMBER SPECIFICATIONS Part Number 2214-40C 2214-80C 2214-120C 2214-200C 2214-300C 2214-400C 2214-500C 2214-600C 2214-800C 2214-50D 2214-100D 2214-150D 2214-200D 2214-250D 2214-300D 2214-400D 2214-500D 2214-600D 2214-800D 2214-1000D 2214-200G 2214-300G 2214-400G 2214-500G 2214-600G 2214-800G 2214-1000G 2214-1200G 2214-1500G 2214-2000G TD (ns) 40.0 2.0 80.0 4.0 120 6.0 200 10.0 300 15.0 400 20.0 500 25.0 600 30.0 800 40.0 50.0 2.5 100 5.0 150 7.5 200 10.0 250 12.5 300 15.0 400 20.0 500 25.0 600 30.0 800 40.0 1000 50.0 200 10.0 300 15.0 400 20.0 500 25.0 600 30.0 800 40.0 1000 50.0 1200 60.0 1500 75.0 2000 100 Delay per Tap (ns) 2.0 1.0 4.0 1.0 6.0 1.0 10.0 1.0 15.0 1.0 20.0 1.0 25.0 1.3 30.0 1.5 40.0 2.0 2.5 1.0 5.0 1.0 7.5 1.0 10.0 1.0 12.5 1.0 15.0 1.0 20.0 1.0 25.0 1.3 30.0 1.5 40.0 2.0 50.0 2.5 10.0 1.0 15.0 1.0 20.0 1.0 25.0 1.3 30.0 1.5 40.0 2.0 50.0 2.5 60.0 3.0 75.0 3.8 100 5.0 TR (ns) 4.0 8.0 12.0 20.0 30.0 40.0 50.0 60.0 80.0 5.0 10.0 15.0 20.0 25.0 30.0 40.0 50.0 60.0 80.0 100 20.0 30.0 40.0 50.0 60.0 80.0 100 120 150 200 Imped. () 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 500 500 500 500 500 500 500 500 500 500 RDC () 7.0 8.0 10.0 13.0 12.0 15.0 17.0 23.0 38.0 7.0 10.0 12.0 22.0 21.0 23.0 26.0 30.0 37.0 41.0 47.0 20.0 37.0 40.0 45.0 52.0 80.0 100 110 130 156 DASH NUMBER SPECIFICATIONS Part Number 2214-50A 2214-60A 2214-80A 2214-100A 2214-150A 2214-200A 2214-50B 2214-60B 2214-80B 2214-100B 2214-150B 2214-200B 2214-300B 2214-400B TD (ns) 50.0 2.5 60.0 3.0 80.0 4.0 100 5.0 150 7.5 200 10.0 50.0 2.5 60.0 3.0 80.0 4.0 100 5.0 150 7.5 200 10.0 300 15.0 400 20.0 Delay per Tap (ns) 2.5 1.0 3.0 1.0 4.0 1.0 5.0 1.0 7.5 1.0 10.0 1.0 2.5 1.0 3.0 1.0 4.0 1.0 5.0 1.0 7.5 1.0 10.0 1.0 15.0 1.0 20.0 1.0 TR (ns) 5.0 6.0 8.0 10.0 15.0 20.0 5.0 6.0 8.0 10.0 15.0 20.0 30.0 40.0 Imped. () 50 50 50 50 50 50 100 100 100 100 100 100 100 100 RDC () 3.2 3.6 5.0 6.0 6.0 7.0 6.0 6.0 6.5 7.0 8.0 8.5 11.0 12.0 (c) 1997 Data Delay Devices Doc #97026 2/7/97 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 1 2214 FUNCTIONAL DIAGRAM T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T17 T18 T19 IN GND T20 PACKAGE DIMENSIONS 24 23 22 21 20 19 18 17 16 15 14 13 .580 MAX. .010 .002 1 2 3 4 5 6 7 8 9 10 11 12 .600 .005 1.270.010 Lead Material: Nickel-Iron alloy 42 TIN PLATE .280 MAX. .015 TYP. .018 TYP. 1.100.010 11 Equal spaces each .100.010 Non-Accumulative .070 MAX. DIP (2214-xxz) .020 TYP. .040 TYP. .010.002 24 23 22 21 20 19 18 17 16 15 14 13 .710 .590 .005 MAX. .882 .005 .007 .005 1 2 3 4 5 6 7 8 9 10 11 12 .090 1.100 1.280.020 .100 .280 MAX. .050 .010 Gull-Wing (2214-xxzC4) Doc #97026 2/7/97 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 2 2214 PASSIVE DELAY LINE TEST SPECIFICATIONS TEST CONDITIONS INPUT: Ambient Temperature: Input Pulse: 25 C 3 C High = 3.0V typical Low = 0.0V typical Source Impedance: 50 Max. Rise/Fall Time: 3.0 ns Max. (measured at 10% and 90% levels) Pulse Width (TD <= 75ns): PWIN = 100ns Period (TD <= 75ns): PERIN = 1000ns Pulse Width (TD > 75ns): PWIN = 2 x TD Period (TD > 75ns): PERIN = 10 x TD o o OUTPUT: Rload: Cload: Threshold: 10M 10pf 50% (Rising & Falling) NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. PERIN PWIN TRISE INPUT SIGNAL 90% 50% 10% TFALL VIH 90% 50% 10% VIL TFALL TRISE TRISE OUTPUT SIGNAL 90% 50% 10% TFALL VOH 90% 50% 10% VOL Timing Diagram For Testing OUT PULSE GENERATOR TRIG RIN IN T1 IN TRIG OSCILLOSCOPE 50 DEVICE UNDER TEST (DUT) T20 RIN = ROUT = ZLINE ROUT Test Setup Doc #97026 2/7/97 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 3 |
Price & Availability of 2214-80C
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |