 FXP7000 AC-DC Series Data Sheet
ront-End tributed Power F Dis
Features
* Three-phase AC input * Suitable for 3U or 5U height mounting * Single-wire current share or Droop current share * Remote voltage adjust and current monitoring * Overtemperature, overload, and overvoltage protection * LED supply status indicators * Current share control for up to 30 units * Standard & customized rack adaptors available
FXP7000 Front and Rear Views
* Front panel selectable-input-range
The FXP7000 Series of rack-mounted power systems provides AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The pluggable FXP supplies do not include an output isolation diode and may be paralleled up to 210 kW of total output power. These supplies provide excellent protection against input voltage transients. Access to interfaces for remote sensing, remote voltage adjust, current sharing, current monitoring, power supply status, standby voltage and inhibit, as well as power connections, is through a connector at the rear of the supply. The FXP has its fan, handles, voltage adjust, and Hot-Pluggable Model
MODEL OUTPUT VOLTAGE INPUT VOLTAGE RANGE 3-PHASE (VAC) ADJUSTMENT RANGE
indicator lights on the front panel and a single hot-plug connector on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. The FXP7000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480VAC, delta or wye.
MAXIMUM OUTPUT CURRENT
LINE REGULATION
LOAD REGULATION (NOTE 1)
INITIAL SETTING ACCURACY
FXP7000-48-S
48V
180 to 264 or 342 to 528
45.6V to 50.4V
145A
0.15%
0.2%
47.90V to 48.10V
NOTES: 1) With Remote Sense connected.
Input Specifications
PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS
Input Voltage - AC
Input Current Inrush Surge Current Input Frequency Hold-up Time Operating Frequency Power Factor
3-phase delta low input range, nominal. 3-phase delta high input range, nominal. Continuous deviation from the above nominals. Per phase at full rated load. FXP7000 at 180 VAC: Internally limited. Vin = 264VAC (one cycle). 25 C: Vin = 528VAC (one cycle). 25 C: AC input. After last AC line peak at full power. 208 VAC: 400 VAC: Switching frequency, fixed.
200 380 -10
50 17 13 100 0.90
240 480 +10 30 38 38 60
VAC % ARMS APK Hz ms kHz W/VA
MAY 31, 2005 revised to JAN 09, 2007
Page 1 of 8
www.power-one.com
FXP7000 AC-DC Series Data Sheet
Output Specifications
PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS
Output Voltage Adjustment Range Output Power Output Current Efficiency Regulation
Ripple & Noise
Overshoot / Undershoot Minimum Loads Transient Response Turn-On Delay Turn-on Rise Time
An additional 1.0 Volt is provided to the output terminals to provide for load lead losses. Continuous duty rating. Continuous duty rating. Full rated load (208Vac). Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. Measured at mating connector w/ 0.01F + 10F Tant. 20 MHz BW: 100 MHz BW: Output voltage overshoot/undershoot at turn-on. Minimum loading required to maintain regulation. Maximum recovery time, to within 1% of initial set Time: point due to a 25% load change, 1A/S. Deviation: Time required for initial output voltage stabilization after power-up. Time required for output voltage to rise from 10% to 90%.
45.6
48
50.4 7000 145
V Watts A %
88
91 0.2 0.75 2.0 0.2 1 2 0
%
% p-p % A s % s ms
0 800 3.2 3 100
Interface Signals and Protection
PARAMETER (NOTE 1,2) DESCRIPTION/CONDITIONS MIN NOM MAX UNITS
AC Power Fail Warning Auxiliary Power Current Monitor
Current Share Input Range Select Status Loss of Phase Warning Output Inhibit Output Interlock Output Overload Protection Output Overload Warning Output Short Circuit Protection Output Voltage Fault Signal Output Voltage Margin Overtemperature/ Fan Failure Warning Overvoltage Protection Power Supply Present Signal Remote Sense
Warning provided prior to Vout dropping 5% after loss of AC input. Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. Output current. Monitor output current over a compliance range of 0~10V. Normal output: Total error current: Static sharing deviation as a percent of full-load rating Active: for loads >10%. Passive: Maximum signal resistance in high input voltage range selection. Warning provided prior to protective reduction in current limit. Voltage required to enable supply (0.5 mA sink). (NOTE 3) Voltage required to enable supply (6 mA sink). (NOTE 3) Straight line current limit (above approx. 5V Vout). Signal level on overload. Occurs on overload when Vout is below approx. 5V. Iavg: May operate in burst-mode. Deviation from adjusted Vout that is considered as a fault. Output voltage swing available through Margin pin (analog). Time between fault warning and shutdown. Latching shutdown. Latch style overvoltage protection. Resistance to logic ground upon insertion of supply. Maximum load lead loss compensation (round trip).
4 11.6
12.0
12.4 500
ms V mA mA/A mA %
0.5
0.10 0
0.5 5 10 0.10 1.0 1.0 156 90
500
149 2.2 25 3 4.8 100 55.2 4 5.0
ms V V A V A % % ms V V
5 5.2
57.6 1000
60.0 1.0
NOTES: 1) All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40 mA sink capability, and a 100k pull-up to 5V. 2) In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature/fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED's indicating output loading. 3) Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details.
MAY 31, 2005 revised to JAN 09, 2007
Page 2 of 8
www.power-one.com
FXP7000 AC-DC Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Voltage Sag Immunity Leakage Current
UL60950/CSA60950-00 (cULus), IEC60950, EN60950 (TUV), CE marked for the Low Voltage Directive FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5. Line-to-Line: Line-to-Ground: Per SEMI F47-0200 FXC/FXP7000 Per UL60950 and FXP7000 at 240 VAC, 60 Hz: EN60950: FXP7000 at 400 VAC, 50 Hz: FXP7000 at 480 VAC, 60 Hz:
A A 8 10 4 4 3 Pending 5 7 10
Class kV V/M kV kV
mA
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration Airflow
Operating. Non-Operating. At 100% load: At 50% load: 0C to 70C (after 15-minute warm-up). Non-Condensing. Operating: half-sine 10 ms, 3 axis Non-operating: half-sine 10 ms, 3 axis Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02iDA, 32-2000 Hz Non-operating: random 10-2000 Hz Airflow provided through the supply from front to rear. 0 -40
10k 40k 40 70 85 .02 95 +20 +40 1 6.15 155 4.4 555 2.8
ASL Ft. C C %/C %RH GPK GPK Grms cfm m3/min lfm m/s lb kg
Weight
29 13
MAY 31, 2005 revised to JAN 09, 2007
Page 3 of 8
www.power-one.com
FXP7000 AC-DC Series Data Sheet
FXP7000 OVERALL SIZE: 16.96" x 8.00" x 5.00" (430.8mm x 203.2mm x 127.0mm)
16.09" (408.7mm) 14.259" (362.18mm) 11.704" (297.28mm) MAINTAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR) FOR AIR COOLING
A A A A
7.509" (190.73mm)
4.954" (125.83mm) 0.87" (22.1mm)
LOCK HANDLE LED HANDLE
5.750" (146.05mm)
<--AIRFLOW SIDE VIEW
A A A A
8.00" (203.2mm)
1.100" (27.94mm)
0.341" (8.66mm) 0.649" (16.48mm)
0.204" (5.18mm)
LOCK HOOK
0.480" (12.19mm)
0.590" (14.99mm)
NOTE: TOTAL BOTTOM STACKUP OF RACK MUST BE NO GREATER THAN 0.204".
16.96" (430.8mm)
A A A A
4.000" (101.6mm)
BOTTOM VIEW
A A A A
1.759" (44.68mm) 15.462" (392.73mm)
FOR OPTIONAL HARD MOUNTING, USE M4 X 0.7 SCREWS, 8PL (MARKED A) ON SIDE OR BOTTOM WITH MAXIMUM PENETRATION 3.8mm. RECOMMENDED MOUNTING TORQUE 10.5 INCH LBS. (0.64N/M)
FRONT VIEW REAR VIEW
5.000" (127mm)
INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC
LOCK HANDLE RELEASE
2.437" (61.90mm)
INPUT VOLTAGE DISPLAY CUTOUT
0.090" (2.29mm) 2PL 0.521" (13.24mm) 3.901" (99.09mm)
CENTER -TOCENTER
480VAC
4.552" (115.62mm) 0.222" (5.64mm) 0.226" (5.74mm)
MATING CONNECTOR INFORMATION
Tyco PN 1648601-1 1648420-1 1648318-1 1648325-1 Elcon PN 296-22-01100 712-12-01107 702-32-01107 702-92-01109 Description CONN HSING FEM 52P TOP DRAWER CONTACT SOCKET #0 DOUBLE CROWN CONN SOCKET #12 BLIND MATE CONN SOCKET #20 BLIND MATE
C L
C L
MAY 31, 2005 revised to JAN 09, 2007
Page 4 of 8
www.power-one.com
FXP7000 AC-DC Series Data Sheet
(R)
FRH7000 POWER SHELF, FRONT VIEW
NOTE: FXP7000 POWER SUPPLIES ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT INCLUDED AS PART OF POWER SHELF ASSEMBLY.
19.000" (482.6mm) 18.312" (465.12mm) 0.129" 4PL (3.28mm)
2.250" 2PL (57.15mm)
480VAC 480VAC
5.215" (132.46mm)
1.484" 2PL (37.69mm) FXP7000 2PL
Note: The FRH7000 Power Shelf is designed for alternative vertical mounting with the right side down.
FRH7000 POWER SHELF, REAR VIEW
5/16-18 STUD 2 PL ACCOMODATES RING LUG 1.08 MAX WIDTH 5.215" (132.46mm)
2.74" 4.38" (69.6mm) (111.25mm)
-
+
AMP PN 213581-1 WITH SILVER-PLATED CONTACTS 1.86" (47.24mm) 2 PL 0.66" (16.76mm) 2 PL 19.000" (482.6mm) 17.14" (435.34mm) 10/32 GROUND STUD 2PL
UNIT LABEL
3.56" (90.4mm) 2 PL
J2 AC INPUTS J3
1 3 2
0.61" (15.5mm) 0.000
3 PHASE 3 WIRE + PE
J1
ATTACH EARTH GNDS BEFORE AC CONNECTORS
9.42" (239.27mm) 0.000
PIN 1
15.14" (384.56mm)
NOTES: 1. FOR CLARITY, FINGER GUARD FOR DC OUTPUT TERMINALS IS NOT SHOWN IN THIS ILLUSTRATION.
50-PIN SIGNAL HEADER WITH KEYING AND LATCHES 15.44" (AMP PN: 1-499141-0) (384.56mm)
16.84" (427.74mm)
MAY 31, 2005 revised to JAN 09, 2007
Page 5 of 8
www.power-one.com
FXP7000 AC-DC Series Data Sheet
FRH7000 POWER SHELF, RIGHT-SIDE VIEW
24.000" (609.6mm) 1/4-20 INSERTS 2 PL EACH SIDE FOR REAR SUPPORT
21.91" (556.5mm)
4.000" (101.6mm)
0.715" (18.16mm) CUSTOMER-SUPPLIED CABLES OR BUS BARS
RACK MOUNTING FLANGE
FILLER PANEL KIT, PN: 088-101378
(Used with FRH7000 Power Shelf)
This kit is used to cover an unused right-side slot of the FRH7000 Power Shelf (as viewed from the front of the FRH7000). The kit can be installed before, or after installation of the power shelf into the rack.
BRACKET, 2 PLACES
FILLER PANEL
(FILLER PANEL KIT AS SEEN FROM INSIDE OF POWER SHELF)
MAY 31, 2005 revised to JAN 09, 2007
Page 6 of 8
www.power-one.com
FXP7000 AC-DC Series Data Sheet
(R)
19.000" (482.6mm) 18.656" 2PL (473.86mm)
NOTE: FXP7000 POWER SUPPLIES ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT INCLUDED AS PART OF POWER SHELF ASSEMBLY.
8.70" (221.0mm)
7.184" 2PL (182.47mm)
INPUT VOLTAGE DISPLAY CUTOUT
0.344" 2PL (8.74mm) R 0.129" 4PL (3.28mm)
AMP PN: 213581-1 WITH SILVER-PLATED PIN CONTACTS
1 3 2
FRV7000 POWER SHELF, FRONT VIEW
INPUT VOLTAGE RANGE SELECT MODULE
1.434" 2PL (36.42mm)
480VAC 480VAC 480VAC
FRV7000 POWER SHELF, REAR VIEW
5/16-18 STUD 2PL ACCOMODATES CABLE LUG 1.08" WIDTH MAX.
- DC OUT +
3.55" (90.17mm)
UNIT LABEL
0.000 2.71" 3PL (68.8mm)
0.000
J2 AC INPUTS J3
1.01" (25.65mm) 0.40" (10.16mm)
3 PHASE
J4
1.07" 3PL (27.2mm)
3W + PE
J1
ATTACH EARTH GNDS BEFORE AC CONNECTORS
0.000 0.000 3.31" (84.07mm) 4.95" (125.73mm) 9.42" (239.27mm)
10/32 PE STUD 3PL PIN 1
13.67" (347.22mm) 15.37" (390.40mm) 17.07" (433.58mm) 16.77" (425.96mm)
13.37" (339.60mm)
NOTES: 1. FOR CLARITY, FINGER GUARD FOR DC OUTPUT TERMINALS IS NOT SHOWN IN THIS ILLUSTRATION.
50-PIN SIGNAL HEADER WITH KEYING AND LATCHES (AMP PN: 1-499141-0)
MAY 31, 2005 revised to JAN 09, 2007
Page 7 of 8
15.07" (382.78mm)
www.power-one.com
FXP7000 AC-DC Series Data Sheet
FRV7000 POWER SHELF, LEFT-SIDE VIEW
22.50" 2PL (571.5mm) 25.56" (649.2mm) 24.00" (609.6mm) 1/4-20 THREADED INSERTS 2PL EACH SIDE FOR REAR SUPPORT OF UNIT. DO NOT EXCEED 0.500" PENETRATION OF SCREW INTO UNIT. 0.000 COOLING AIR INTAKE
0.214" 0.000 (5.44mm)
7.20" (182.9mm) COOLING AIR EXHAUST
FINGER GUARD FOR DC OUTPUT TERMINALS
1.20" (30.5mm) 0.40" (10.2mm)
CUSTOMER-SUPPLIED DC CABLES
POWER SUPPLY LOCK HOOK; CLEARANCE REQUIRED 6 PLACES
FILLER PANEL KIT, PN: 088-101348
(Used with FRV7000 Power Shelf)
This kit is used to cover an unused left or center slot of the FRV7000 Power Shelf (as viewed from the front of the FRV7000). One kit is required per slot. Kits can be installed before, or after installation of the power shelf into the rack.
UPPER BRACKET
FILLER PANEL
LOWER BRACKET
(FILLER PANEL KIT AS SEEN FROM INSIDE OF POWER SHELF)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
MAY 31, 2005 revised to JAN 09, 2007
Page 8 of 8
www.power-one.com


▲Up To Search▲   

 
Price & Availability of FXP7000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X