![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PLL130-05 High Speed Translator Buffer to PECL (Enable Low) FEATURES * * * * * Differential PECL output Single AC coupled input (min. 100mV swing). Input range from DC to 1.0 GHz. 2.5V to 3.3V operation. Available in 3x3mm QFN. GND GND GND PIN CONFIGURATION (TOP VIEW) GND 9 VDD 11 VDD 13 14 15 16 12 VDD 10 8 7 6 5 PECL_BAR VDD PECL GND PLL130-05 1 2 3 4 DESCRIPTION The PLL130-05 is a low cost, high performance, high speed, buffer that reproduces any input frequency from DC to 1.3GHz. It provides one pair of differential PECL outputs. Any input signal with at least 100mV swing can be used as reference signal. This chip is ideal for conversion from sine wave, TTL, CMOS, or LVDS to PECL. OE V REF_IN GND GND Note: V denotes internal pull down BLOCK DIAGRAM REF_IN Input PECL_BAR PECL Amplifier 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 09/09/04 Page 1 GND PLL130-05 High Speed Translator Buffer to PECL (Enable Low) PIN DESCRIPTIONS Name GND VDD REF_IN PECL PECL_BAR OE 3x3mm QFN Pin number 1,2,4,5, 9,13,14,15 7,10,11,12 3 6 8 16 Type P P I O O I Ground. Description Power supply. Reference input signal. The frequency of this signal will be reproduced at the output (after translation to PECL level). PECL True output. PECL Complementary output. Output enable (`0' for enable). Internal pull-down (default is `0'). ELECTRICAL SPECIFICATIONS 1. Absolute Maximum Ratings PARAMETERS Supply Voltage Input Voltage, dc Output Voltage, dc Storage Temperature Ambient Operating Temperature* Junction Temperature Lead Temperature (soldering, 10s) ESD Protection, Human Body Model SYMBOL VDD VI VO TS TA TJ MIN. -0.5 -0.5 -65 -40 MAX. 4.6 VDD+0.5 VDD+0.5 150 85 125 260 2 UNITS V V V C C C C kV Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the device and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other conditions above the operational limits noted in this specification is not implied. * Note: Operating Temperature is guaranteed by design for all parts (COMMERCIAL and INDUSTRIAL), but tested for COMMERCIAL grade only. 2. AC Specification PARAMETERS Input Frequency Input signal swing Output Frequency Output Rise Time Output Fall Time CONDITIONS REF_IN input 0.8V to 2.0V with no load 2.0V to 0.8V with no load MIN. 0 100 0 TYP. MAX. 1000 1000 1.5 1.5 UNITS MHz mV MHz ns ns 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 09/09/04 Page 2 PLL130-05 High Speed Translator Buffer to PECL (Enable Low) 3. PECL Electrical Characteristics PARAMETERS Output High Voltage Output Low Voltage SYMBOL VOH VOL CONDITIONS RL = 50 to (VDD - 2V) (see figure) MIN. VDD - 1.025 MAX. VDD - 1.620 UNITS V V 4. PECL Switching Characteristics PARAMETERS Clock Rise Time Clock Fall Time SYMBOL tr tf CONDITIONS @20/80% - PECL @80/20% - PECL MIN. TYP. 0.6 0.5 MAX. 1.5 1.5 UNITS ns ns PECL Levels Test Circuit OUT VDD OUT PECL Output Skew 50 2.0V 50% 50 OUT OUT tSKEW PECL Transistion Time Waveform DUTY CYCLE 45 - 55% 55 - 45% OUT 80% 50% 20% OUT tR tF 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 09/09/04 Page 3 PLL130-05 High Speed Translator Buffer to PECL (Enable Low) PACKAGE INFORMATION ORDERING INFORMATION For part ordering, please contact our Sales Department: 47745 Fremont Blvd., Fremont, CA 94538, USA Tel: (510) 492-0990 Fax: (510) 492-0991 PART NUMBER The order number for this device is a combination of the following: Device number, Package type and Operating temperature range PLL130-05 S C PART NUMBER TEMPERATURE C=COMMERCIAL I=INDUSTRAL PACKAGE TYPE Q=QFN Order Number PLL130-05QC-R PLL130-05QC Marking P130-05QC P130-05QC Package Option QFN - Tape and Reel QFN - Tube PhaseLink Corporation, reserves the right to make changes in its products or specifications, or both at any time without notice. The information furnished by Phaselink is believed to be accurate and reliable. However, PhaseLink makes no guarantee or warranty concerning the accuracy of said information and shall not be responsible for any loss or damage of whatever nature resulting from the use of, or reliance upon this product. LIFE SUPPORT POLICY: PhaseLink's products are not authorized for use as critical components in life support devices or systems without the express written approval of the President of PhaseLink Corporation. 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 09/09/04 Page 4 |
Price & Availability of PLL130-05SI
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |