Filename: 448.doc version 1.1 16.05.2002 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedances * Input: Output: 23 C 0 dBm Filter Specification TFS 448 1/5 340 || -1,05 pF 340 || -1,05 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS448 is the maximum of the pass band attenuation amax. The maximum of the attenuation within the usable signal bandwidth is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 448,0125 MHz without tolerance. The given values for the relative attenuation have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion loss (Reference level) Nominal frequency Centre frequency 3 dB - bandwidth Usable signal bandwidth Relative attenuation fN + 910 kHz Temperature coefficient of frequency Frequency inversion temperature Operating temperature range Storage temperature range arel TCf ** ae = amax fN fc BW typ. value 448,02 MHz 255 60 dB 2 Variation / Limitation max. 5 dB 448,0125 MHz min. fN 10 min. 52 - 10C ... + 50C - 30C ... + 85C kHz dB kHz -0,036 ppm/K +10 C T0 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz) generated: checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 448.doc version 1.1 16.05.2002 VI TELEFILTER Construction and pin connection (All dimensions in mm) Filter Specification TFS 448 2/5 1 - Input 2 - Ground 3 - Ground 4 - Output 3,00,3 Datecode M N P ... Year + week 2000 2001 2002 Datecode S 448 P20 50 test circuit 1 L1 1 4 L2 C1 C2 2,3 50 test circuit 2 C1 1 4 C2 L1 L2 2,3 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 448.doc version 1.1 16.05.2002 VI TELEFILTER Stability Characteristics Filter Specification TFS 448 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 448.doc version 1.1 16.05.2002 VI TELEFILTER Air reflow temperature conditions Filter Specification TFS 448 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: 448.doc version 1.1 16.05.2002 VI TELEFILTER History Version 1.0 1.1 Reason of Changes Filter Specification TFS 448 5/5 Name Dr. Wall Dr. Wall Date 01.03.2002 16.05.2002 Generate specification according to customer requirements. Change from development spezification to filter specification. Define termination impedance. Correct typical data according to measurement results. VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS448
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |