__________________________________________________________________________________ VI TELEFILTER Filter specification TFS 70 F - 1/3 __________________________________________________________________________________
Package, pin connection and 50 matching network see page 2.
Version 2.2
06.01.02
1. Measurement condition
Ambient temperature TA: 25 C Input power level: 0 dBm (typ.) Max 10 dBm. Terminating impedances at fc: for input: 53 -40 pF. for output: 54 -40 pF. 2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFD 70F is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data typ. value tolerance / limit ___________________________________________________________________________________________________ 22.5 dB max 25 dB Insertion loss (Reference level) ae ___________________________________________________________________________________________________ Reference frequency fc at ambient temperature (fCTA) 70 MHz 70 0.1 MHz ___________________________________________________________________________________________________ 1 dB - band width 12.24 MHz 3 dB - band width 12.45 MHz 40 dB - band width 13.23 MHz 45 dB - band width 13.30 MHz ___________________________________________________________________________________________________ Amplitude ripple (p-p): fc ... fc 6.1 MHz 0.5 dB max 1.0 dB ___________________________________________________________________________________________________ Relative attenuation arel fc fc 6.1 MHz max 1 dB fc 6.1 MHz fc 6.2 MHz max 3 dB fc 6.65 MHz fc 6.7 MHz*) 45 dB min 40 dB fc - 69 MHz fc - 6.7 MHz 55 dB min 45 dB fc + 6.7 MHz fc + 20 MHz 55 dB min 45 dB fc + 20 MHz fc + 35 MHz 45 dB min 40 dB ___________________________________________________________________________________________________ Group delay 4.1 s max 4.5 s ___________________________________________________________________________________________________ Group delay ripple (p-p): fc ... fc 6.0 MHz 50 ns max 100 ns ___________________________________________________________________________________________________ Deviation from linear phase (p-p): fc ... fc 6.0 MHz 7.5 (p-p) ___________________________________________________________________________________________________ Triple transit attenuation compared to main signal 52 dB ___________________________________________________________________________________________________ Input/Output return loss with matching network (S11/S22): 3.6/3.7 dB ___________________________________________________________________________________________________ Crosstalk 65 dB ___________________________________________________________________________________________________ Substrate material LiNbO3 ___________________________________________________________________________________________________ Temperature coefficient of frequency ( Tcf ) -86 -94 ppm/K ___________________________________________________________________________________________________ Frequency deviation of fc over temperature fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) ___________________________________________________________________________________________________ Operating temperature range - 25 C ... + 80 C Storage temperature range - 40 C ... + 85 C ___________________________________________________________________________________________________ *) in this frequency range the limit line is of type SLOPING LINE Generated: Checked/Approved: Weinberg Dr. Bert Wall
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS70F.doc
__________________________________________________________________________________ VI TELEFILTER Filter specification TFS 70 F - 2/3 __________________________________________________________________________________
3. Package
Version 2.2
06.01.02
35 Max 24 20.5 Max 1 13
TFS 70 F tft
12
Pin 23 Pin 24 Pin 11 Pin 12 Pin 5-8,17-20
Input Input RF Return Output Output RF Return Pakage Ground
5.5 5.5 Max
1
12
15.24
24 2.54 11x2.54=27.94
13
4. 50 matching network:
1
11 12
L3 L1* C1*
L4** C2**
L2
24 23
13
L2 = 217 5 nH L3 = 100 5 nH *) L1 = 465 10 nH 1/ L1 C1 = 2 f1, **) L4 = 200 10 nH 1/ L4 C2 = 2
C1 = 70 pF.
f
1
= 28.937 MHz C2 = 10.6 pF.
2
f,
2
f
= 107.375 MHz
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS70F.doc
__________________________________________________________________________________ VI TELEFILTER Filter specification TFS 70 F - 3/3 __________________________________________________________________________________ Air reflow temperature conditions
Version 2.2
06.01.02
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS70F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X