Part Number Hot Search : 
0420S14I 55002 HA273 H0R6B SSG9962 IL3480 A1500 HER107
Product Description
Full Text Search
 

To Download TFS70H25 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS70H25.doc
version 1.3
03.01.02
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedances *: for input: for output: 25 C 10 dBm 385 524 // -13,4 pF // -11,6 pF
Filter Specification
TFS 70H25
1/5
Remark:
Reference level for the relative attenuation arel of the TFS 70H25 is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal frequency fn . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tc f is valid for both the reference frequency f c and the frequency response of the filter on the operating temperature.
Data
Insertion loss (Reference level) Nominal frequency ae
typ. value
21,8 dB
tolerance/limit
max. 25,0 dB
fn
-
70,0
MHz
Passband Passband variation 1 dB bandwidth 3 dB bandwidth 40 dB bandwidth
PB p-p BW BW BW
fn
0,65 0,60
MHz dB MHz MHz MHz
0,45 1,55 1,72 2,55
dB MHz MHz MHz min. min. max.
1,30 1,50 2,80
Relative attenuation arel fn 0,75 MHz ....... fn fn 1,40 MHz ....... fn 2,50 MHz 2,50 MHz ....... fn 30 MHz 45 52 3 160 - 0.036 dB dB ns ppm/K
max. min. min. max.
3 40 50 6
dB dB dB ns
Phase linearity in PB Group delay variation in PB Temperature coefficient of frequency ( Tcf ) Frequency deviation of f c over temperature T: Operating temperature
max. 200
fc(Hz) = Tcf(ppm/K ) x (T - TA) x fCAT (MHz) 25 C
2
2
Storage temperature range - 25..... + 85 C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated: Checked / approved:
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H25.doc
version 1.3
03.01.02
VI TELEFILTER
Filter Specification
TFS 70H25
2/5
Construction, pin configuration and 50
(All dimensions in inch)
- matching network
18
11 10
TFS 70 H 25 N48
12
27,18 0,20
Date code: M N P ....
Year+week 2000 2001 2002
9
1
o0,450,05
Pin Configuration Input: Input Return: Output: Output Return: Ground: 18 1 10 9 2,11
2,54 0,20 20,32 0,20
50 Ohm test circuit
L1
18
10
L2
IN
TFS 70H25
OUT
1,2, 9,11
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H25.doc
version 1.3
03.01.02
VI TELEFILTER
Filter Specification
TFS 70H25
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 1,5 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H25.doc
version 1.3
03.01.02
VI TELEFILTER
Filter Specification
TFS 70H25
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H25.doc
version 1.3
03.01.02
VI TELEFILTER
History version
1.0 1.1 1.2 1.3
Filter Specification
name
Pfeiffer Pfeiffer Pfeiffer Pfeiffer
TFS 70H25
date
5/5
reason of changes
generate specification terminated impedances added package changed pin cinfiguration changed
22.03.2001 12.04.2001 27.11.2001 03.01.2002
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS70H25

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X