![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
NHC3000 AC-DC Series Data Sheet Features * Single-phase AC input * 3U height * Active current share * Power Factor Correction (PFC) Meets EN61000-3-2 * Remote voltage adjust, and current monitoring * Overtemperature, overload, and overvoltage protection * Power supply status indicators * Output current meter (bar graph) * MTBF> 700,000 hours Description The NHC3000 Series of chassis-mounted power systems provides AC front-end capability to telecom, data communications and other distributed power designs. The NHC3000 can also be used for many other applications requiring bulk power. NHC3000 power supplies provide excellent protection against input voltage transients. A connector at the rear of the supply provides access to interfaces for remote sensing, remote voltage adjust, current sharing, power supply status, standby logic voltage, remote on/off, and power connections. Airflow for the NHC3000 is from the front through the rear. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. Model Selection MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION (NOTE 1) RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY NHC3011-5 NHC3011-6 NHC3021-8 24V 28V 48V 21.6V to 26.4V 25.2V to 30.8V 43.2V to 52.8V 125A 107A 62.5A 0.2% 0.2% 0.2% 0.4% 0.4% 0.4% 1% 1% 1% 23.95V to 24.05V 27.92V to 28.08V 47.90V to 48.10V NOTES: 1) With Remote Sense connected. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Input Frequency Hold-up Time Input Current Inrush Surge Current Power Factor Operating Frequency Single-phase continuous input range. AC input. AC turn-off to output greater than or equal to 95%. At full rated load per module. Per EN61000-3-2 at full load. At half load. Switching frequency 180 47 16 at 230 VAC 0.99 0.98 140 15.0 264 63 30 VAC Hz ms ARMS APK W/VA kHz JUN 03, 2004 revised to MAY 26, 2006 Page 1 of 4 www.power-one.com NHC3000 AC-DC Series Data Sheet Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Minimum Loads Output Power Overshoot / Undershoot Transient Response Turn-On Delay Time Turn-on Rise Time Full rated load. Minimum loading required to maintain regulation. Per module. Output voltage overshoot/undershoot at turn-on. Maximum recovery time, to within 1% of initial set point due to a 50-100-50% load change, 1A/s, 3.0% max. deviation. AC turn-on to output >95%. Time required for output voltage to rise from 10% to 90%. 88 0 3000 3.0 500 1.2 100 2.0 % A Watts % s Sec ms Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. 24V model 28V model 48V model Overcurrent Protection Short Circuit Protection Overtemperature DC OK, Output Good (Module) Input Power Fail Warning Current Monitor Current Share Accuracy Remote Sense Auxiliary Power (Logic Power) Output Margin Power Fail Signal & PF Warning Time Output Voltage and Current Programming Constant current limit, as a percentage of maximum rated load. Short circuit current, as a percentage of maximum rated load. Output recovers automatically after removal of short. Module shuts down when internal temperature reaches an unsafe level. Output low threshold measured at output studs. Form C contacts, rating is 500 mA at 30 VDC. Relay closes >5 ms before output drops to <95%. Relay opens after output is in regulation. Form C contacts, pull-up to +5 V through a 1 k resistor. Signal provides an output of 0-10V which applies over 10-100% of rated load. At 50% load: Applies over 10-100% load as a percentage of full load. Total voltage compensation for cable losses with respect to the main output. Referenced to negative output terminal and derived from the internal 5.1 VDC. Margin High - Connect Margin input to Margin Ref. Margin Low - Connect Margin input to Logic Common. PF drops to "0" before output drops to 95% due to loss of AC. PF goes to "1" (logic high) after +5 V is in regulation. Form C Warning Time: contacts pull up to +5 V through a 1 k resistor. Optional - Consult factory for details.. 26.4 30.8 52.8 100 105 27.6 33.8 55.2 110 110 V % % 2 5 5 8 % ms 4.5 5 0.5 5.5 50 +5 -5 5 VDC % V mA % ms Mechanical Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Connector Output Connector Signal Connector J1 Visual Indicators Cooling Mounting Terminal block. Copper bus bar blade with single round hole for 5/16 screw. Power-One P/N 10X0172-001, Amp 247846-4, ITT Common ZEDBL25SBA Mates with Power=One P/N 10X0105-000, Amp 202208-1, ITT Common DBA25-K87-F0 Mating Pin P/N 12X0005-000, Amp 66506-8 AC-OK LED and DC-OK LED located on the connector end of the supply. Internal fan; approximately 100 CFM. See outline drawing. JUN 03, 2004 revised to MAY 26, 2006 Page 2 of 4 www.power-one.com NHC3000 AC-DC Series Data Sheet Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals Electromagnetic Interference Conducted & Radiated ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Conducted Susceptibility Leakage Current UL 60950-1 (UL), CSA C22.2 No. 60950-1, EN60950-1 (TUV), CE Mark, and CB Report FCC CFR title 47 Part 15 Sub-Part B. A EN55022 / CISPR 22. A Per EN61000-4-2, level 3, direct discharge. 8 Per EN61000-4-2, level 3, air discharge. 15 Per EN61000-4-3, level 3. 10 Per EN61000-4-4, level 3, @ 5 kHz. 2 Per EN61000-4-5, level 3. Line to Line 2 Per EN61000-4-6, level 3; 10V from 150 Hz to 80 MHz. Per EN60950. at 240 VAC Class kV V/m kV kV 1.5 mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Storage Temperature Operating Temperature Temperature Coefficient Humidity, Non-Condensing Altitude Shock Vibration Acoustics Weight Derate linearly to 60% at 70 C After 15-minute warmup. Derate at 7C/1000 ft above 8000 ft. Operating: half-sine 10 ms, 3 axis. Non-operating: half-sine 10 ms, 3 axis. Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02iDA, 32-2000 Hz. Non-operating: random 10-2000 Hz. Sound pressure level at 1 meter. -40 0 0.008 5 85 50 95 13,000 +20 +40 1 6.15 57 12.1 5.49 C C %/C % ft GPK GPK Grms dbA lb kg NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUN 03, 2004 revised to MAY 26, 2006 Page 3 of 4 www.power-one.com NHC3000 AC-DC Series Data Sheet NHC3000 OVERALL SIZE: 12.25" x 5.00" x 5.00" (311.2mm x 127.0mm x 127.0mm) A B D AIRFLOW DIRECTION C N F P N K L E G H 0.25" M T R S U J1 V W J1 Connector Pinout Callout A B C D E F G H K M N P R S T U V W Inches 12.25 1.50 0.12 5.00 5.00 3.98 2.86 0.49 1.17 2.19 1.36 2.16 O 0.34 0.80 0.650 3.700 0.825 9.425 Millimeters 311.2 38.1 3.1 127.0 127.0 101.1 72.6 12.5 29.7 55.6 34.5 54.9 O 8.6 20.3 16.51 93.98 21.0 239.4 Pin 1 2 3 4 5 6 7 8 9 10 11 12 Description DC OK N/C DC OK COM DC OK N/O POWER FAIL PULL UP ENABLE PULL UP POWER FAIL POWER FAIL RTN REMOTE ON/OFF REMOTE ON/OFF RTN CURRENT MONITOR MARGIN REF MARGIN Pin 13 14 15 16 17 18 19 20 21 22 23 24 25 Description CURRENT SHARE +5V LOGIC (-) SENSE (+) SENSE N/U N/U I PROGRAM (OPTIONAL LOGIC COM N/U N/U N/U N/U RESERVED FOR OPTIONS JUN 03, 2004 revised to MAY 26, 2006 Page 4 of 4 www.power-one.com |
Price & Availability of NHC3000
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |