Part Number Hot Search : 
XBXXX 600ETTT 20001 SN54LS15 SMBJ33A D1556 74LCX CFD1264P
Product Description
Full Text Search
 

To Download AV131-315 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Preliminary
HIP3TM Variable Attenuator for AMPS and GSM Base Stations
AV131-315 Features
23 dB Attenuation Range 1.5 dB Insertion Loss, 1.5 SWR 0-12 V Control Voltage 43 dBm IP3 Small Footprint LGA Package Designed for AMPS and GSM Base Stations
Description
The AV131-315 is a voltage controlled variable attenuator from Skyworks' series of HIP3TM components. It is specifically designed and specified for use as a wide dynamic range low distortion attenuator for AMPS and GSM base station applications centered at 881.5 MHz and 942.5 MHz. The AV131-315 employs a monolithic quadrature hybrid and a pair of silicon PIN diodes to achieve the specified low distortion performance. It operates from 0-12 V at 1.6 mA typical control current at maximum attenuation. The AV131-315 is packaged in a small outline LGA (Land Grid Array) surface mount package with the internal elements affixed to an organic BT substrate.
Electrical Specifications at 25C
Parameter AMPS Frequency Range (BW) GSM Frequency Range (BW) Control Voltage (CV) Range Insertion Loss in BW Attenuation Range VSWR in BW IP3 IM3 900/905 MHz, CV = 0 V 8 dBm 43 -70 CV = 0 V At FO, CV = 10 V At FO, CV = 12 V 18 23 Condition Min. 869 925 0 Typ. Max. 894 960 12 1.5 22 - 1.5 dBm dBc Unit MHz MHz V dB dB dB
Skyworks Solutions, Inc. [781] 376-3000 * Fax [781] 376-3100 * Email sales@skyworksinc.com * www.skyworksinc.com
Specifications subject to change without notice. 3/03A
1
HIP3TM Variable Attenuator for AMPS and GSM Base Stations
AV131-315
Typical Performance Data
0 -5 0V 4V 0 -0.05 -0.10 -0.15 -0.20 -0.25 -0.30 -0.35 -0.40 12 V -30 0.865 0.875 0.885 0.895 -0.45 -0.50 0 2 4 6 8 10 12
Loss (dB)
-10 -15 -20 -25
8V
Frequency (GHz)
Flatness (dB)
Control Voltage (V)
Insertion Loss vs. Frequency and Control Voltage -- AMPS Band
-10 -15 -20 0V -25 -30 -35 0.865 8V 12 V 10 9 8 7 6 5 4 3 2 1 0.875 0.885 0.895
Insertion Loss Flatness vs. Control Voltage -- AMPS Band
Return Loss (dB)
4V
Phase (Degrees)
12 V
8V 0V 0.875 4V 0.885 0.895
0 0.865
Frequency (GHz)
Frequency (GHz)
Input/Output Return Loss vs. Frequency and Control Voltage -- AMPS Band
50 48 46 44
Phase vs. Frequency and Control Voltage -- AMPS Band
IP3 (dBm)
42 40 38 36 34 32 30 0 2 4 6 8 10 12
Control Voltage (V)
3rd Order Intermod vs. Control Voltage RF1 = 0.900 GHz, RF2 = 0.905 GHz @ 8 dBm
2
Skyworks Solutions, Inc. [781] 376-3000 * Fax [781] 376-3100 * Email sales@skyworksinc.com * www.skyworksinc.com
Specifications subject to change without notice. 3/03A
HIP3TM Variable Attenuator for AMPS and GSM Base Stations
AV131-315
0 -5 -10 4V 8V 0V
0 -0.05 -0.10 -0.15 -0.20 -0.25 -0.30 -0.35 -0.40 12 V 0.930 0.940 0.950 0.960 -0.45 -0.50 0 2 4 6 8 10 12 14
-15 -20 -25 -30 -35 0.920
Frequency (GHz)
Flatness (dB)
Loss (dB)
Control Voltage (V)
Insertion Loss vs. Frequency and Control Voltage -- GSM Band
-10 -15 12 V 10 9 8 7 6 5 4 3 2 1 -35 0.920 0.930 0.940 0.950 0.960 0 0.92
Insertion Loss Flatness vs. Control Voltage -- GSM Band
12 V
Return Loss (dB)
-20 0V -25 -30
4V
8V
Phase (Degrees)
8V 0V 4V 0.93 0.94 0.95 0.96
Frequency (GHz)
Frequency (GHz)
Input/Output Return Loss vs. Frequency and Control Voltage -- GSM Band
50 48 2.0
Phase vs. Frequency and Control Voltage -- GSM Band
Total Current (mA)
46 44
1.5
IP3 (dBm)
42 40 38 36 34 32 30 0 2 4 6 8 10 12 14
1.0
0.5
0
0
3
6
9
12
Control Voltage (V)
Control Voltage (V)
3rd Order Intermod vs. Control Voltage RF1 = 0.900 GHz, RF2 = 0.905 GHz @ 8 dBm
Total Current vs. Control Voltage
Skyworks Solutions, Inc. [781] 376-3000 * Fax [781] 376-3100 * Email sales@skyworksinc.com * www.skyworksinc.com
Specifications subject to change without notice. 3/03A
3
HIP3TM Variable Attenuator for AMPS and GSM Base Stations
AV131-315
Pin Out (Bottom View)
Vcontrol Vcontrol GND
Connection Diagram
RF IN/OUT B3 GND A3 IN/OUT 10 pF
C1 GND B1 A1 IN/OUT
C2
C3
Vcontrol 10 pF CONTROL VOLTAGE
AV131
A2 GND
RF IN/OUT 10 pF
Vcontrol
Terminal No. A1 (Pin 1) A2 A3 B1 B3 C1 C2 C3
Terminal Name IN/OUT GND IN/OUT GND GND Vcontrol GND Vcontrol
0.126 (3.20 mm) 0.004 (0.10 mm) 0.063 (1.60 mm) DETAIL A 0.193 (4.90 mm) 0.004 (0.10 mm)
10 pF
-315
8X 0.004 (0.100 mm) 0.107 (2.740 mm) 0.001 0.004 (0.100 mm) (0.02 mm)
C L
C L
Absolute Maximum Ratings
Characteristic RF Input Power Control Voltage Control Current Operating Temperature Storage Temperature Maximum Reverse Diode Voltage Electrostatic Discharge Value 0.5 W CW, 4 W @ 12.5% Duty Cycle 15 V 50 mA Each Diode -40 to +85C -40 to +85C -10 V +125 V
DETAIL A DETAIL B 0.030 (0.775 mm) 0.002 (0.050 mm)
PIN 1 INDICATOR 0.091 (2.32 mm) 0.003 (0.091 mm)
0.031 (0.800 mm) 0.002 (0.050 mm) DETAIL C DETAIL B 0.031 (0.800 mm) 0.002 (0.050 mm)
0.024 (0.600 mm) 0.002 (0.050 mm) DETAIL C MOLD
Note: Operating this device above any of these parameters may cause irreversible damage.
0.078 (2.00 mm) 0.002 (0.05 mm) 0.013 (0.32 mm) 0.002 (0.4 mm) SEATING PLANE
4
Skyworks Solutions, Inc. [781] 376-3000 * Fax [781] 376-3100 * Email sales@skyworksinc.com * www.skyworksinc.com
Specifications subject to change without notice. 3/03A


▲Up To Search▲   

 
Price & Availability of AV131-315

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X