|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Embedded Power for Business-Critical Continuity TM Intelligent MP Series Up to 1500 Watts Total Power: Up to 1500 Watts Input Voltage: 85 - 264 VAC 120-300 VDC # of Outputs: Up to 21 Rev. 10.09.08_77 IMP Series 1 of 8 Font: Minion Bold for MP Minion italic for i ; size for each is the same Created on Mac Color: "i" 100% Blue, 50% Magenta, 0% Yellow, 0% Black "MP" - 100% Black Special Features * Full Medical EN60601 approval * Intelligent I2C control * Voltage adjustment on all outputs (Manual or I2C) * Configurable input and output (case and module) OK signals and indicators * Configurable inhibit/enable * Configurable output UP/DOWN sequencing * Configurable current limit (foldback or constant current) * High power density (8.8 W/cu-in) * Intelligent fan (speed control/fault status) * Downloadable GUI from website * Customer provided air option * uP controlled PFC input with active inrush protection * I2C monitor of voltage, current, and temp * Programmable voltage, current limit, inhibit/enable through I2C * Optional extended hold-up module (SEMI F47 compliance) * Increased power density to 50% over standard MP * External switching frequency sync input * Optional conformal coating * Industrial temp range (-40 C to 70 C) * No preload required * Industrial shock/vibration (>50G's) Electrical Specifications Input Input range: Frequency: Inrush current: Efficiency: Power Factor: Turn-on time: EMI filter: Leakage current: Radiated EMI: Holdover storage: 85-264 Vac 120-350 Vdc (limited to 300 Vdc in medical applications) 47-440 Hz 40 A peak max. (soft start) Up to 85% @ full case load 0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz) AC on 2.0 sec typ., inhibit/enable 150ms typical Programmable delay; 50ms internal turn-on delay (Dual Output only) CISPR 22/EN55022 Level "B" 300A max. @ 240 Vac; 47 - 63 Hz CISPR 22/EN55022 Level "B" 20 ms minimum (independent of input Vac) additional 34ms holdover storage with optional HUP module (SEMI F47 compatible). For IMP4 15 ms (low-line), 10 ms (high-line) >5 ms early warning min. before outputs lose regulation Full cycle ride thru (50 Hz) (n/a on IMP4> 750 W @ 90 Vac) Meets EN61000-3-2 Meets EN60950 and EN60601 IMP4: 16 A; IMP8: 20 A; IMP1: 25 A (both lines fused) 2 years AC OK: Harmonic distortion: Isolation: Input fuse (internal): Warranty: Global Inhibit/Enable: TTL, Logic "1" and Logic "0"; configurable Safety UL CSA VDE BABT CB CE UL60950/UL2601 CSA22.2 No. 234 Level 5 EN60950/EN60601-1 Compliance to EN60950/EN60601 BS7002 Certificate and report Mark to LVD Embedded Power for Business-Critical Continuity Output Adjustment range:* Margining: Overall regulation: Ripple: 10% minimum all outputs (manual) (full module adjustment range using I2C) 4-6% nominal analog (single output module only) 0.4% or 20mV max. (36 W modules 4% maximum) RMS: 0.1% or 10mV, whichever is greater Pk-Pk: 1.0% or 50mV, whichever is greater Bandwidth limited to 20 MHz <2% or 100mV, with 25% load step To within 1% in <300 sec Configurable through I2C (calibration required). Single output module and main output of the dual output module 105120% of rated output current. Aux output of dual output module 105-140% of rated output current Rev. 10.09.08_77 IMP Series of 8 Output (cont.) Configurable through I2C All outputs disabled when internal temp exceeds safe operating range. >5ms warning (AC OK signal) before shutdown Remote sense: Up to 0.5 V total drop (not available on triple output module) Single wire parallel: Current share to within 2% of total rated current DC OK:* 5% of nominal. Configurable through I2C Minimum load: Not required Housekeeping standby: 5 Vdc @ 1.0 A max. present whenever AC input is applied (Optional 2.0 A available) Module inhibit:* Configured and controlled through I2C Switching frequency: 250k Hz accepts external sync signal Output/Output isolation: >1 Megohm, 500 V External sync: TTL clock input signal used to adjust switching frequency. Frequency 500 kHz 20%; Duty cycle 40 - 55% * Can be controlled via I2C ** Controlled via I2C but requires load calibration Thermal protection:* (OTP and OTW) Dynamic response: Recovery time: Overcurrent protection:** Short-circuit protection: Protected for continuous short-circuit Recovery is automatic upon removal of short Overvoltage protection:* Configurable through I2C Single output module: Dual output module: Triple output module: 2-5.5 V 122-134% ; 6-60 V 110-120% 2-6 V 122-134% ; 8-28 V 110-120% 110-120% of highest voltage rating Reverse voltage protection: 100% of rated output current Environmental Specifications Operating temperature: -40 to 70 C ambient. Derate each output 2.5% per degree from 50 C to 70 C. ( -20 C start up) Storage temperature: -40 C to 85 C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 95% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated >550,000 hours at full load, 220 Vac and 25 C ambient conditions Output Module Line-up Module Code Module Type Max output power Max output current Output voltages available* Standard voltage increments Remote sense Remote margin V-Program - I2C control Active current share Module Inhibit - I2C control Module Inhibit - analog Overvoltage / overcurrent protection Minimum load required Slots occupied in any IMP case 1 Single 210 W 35 A 2-60 V 25 Yes Yes Yes Yes Yes Yes Yes No 1 2 Single 360 W 60 A 2-60 V 25 Yes Yes Yes Yes Yes Yes Yes No 2 3 Single 750 W 150 A 2-60 V 25 Yes Yes Yes Yes Yes Yes Yes No 3 Yes No Yes Yes Yes Yes Yes No 1 4 Dual 144 W 10 A 6 - 15, 24 - 28; 6 - 15, 6 - 15; 6 - 15, 2 - 6; 2 - 6, 2 - 6; 24 - 28, 24 - 28; 24 - 28, 2 - 6 16 Yes No Yes No Yes No Yes No Triple 36 W 2A 8-15, 8-15, 2-6; 8-15, 8-15, 8-15; 8-15, 8-15, 18-28; 8-15, 18-28, 2-6 18 No No No No Yes No Yes No 1 Embedded Power for Business-Critical Continuity Output Module Voltage/Current Voltage Voltage Code Single Output Module Code Dual Output** Triple Output 2V 2.2 V 3V 3.3 V 5V 5.2 V 5.5 V 6.0 V 8.0 V 10 V 11 V 12 V 14 V 15 V 18 V 20 V 24 V 28 V 30 V 33 V 36 V 42 V 48 V 54 V 60 V Non-std* A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 35 A 35 A 35 A 35 A 35 A 35 A 34 A 23 A 20 A 18 A 17 A 17 A 14 A 14 A 11 A 10.5 A 8.5 A 6.7 A 6.5 A 6.2 A 5.8 A 4.2 A 4.0 A 3.7 A 3.5 A 2 60 A 60 A 60 A 60 A 60 A 60 A 58 A 42 A 36 A 32 A 31 A 30 A 21 A 20 A 19 A 18 A 15 A 11 A 11 A 10.9 A 10 A 7.5 A 7.5 A 6.0 A 6.0 A 3 150 A 150 A 150 A 150 A 150 A 144 A 136 A 97.5 A 84.4 A 75 A 68 A 62.5 A 53.5 A 50 A 41.6 A 37.5 A 30 A 26.8 A 25 A 22.7 A 20.8 A 16 A 15.6 A 13.9 A 12.5 A V1 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 9A 8A -- -- 4A 3A -- -- -- -- -- -- -- V2 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 4A 4A 4A 4A 4A 4A -- -- 2A 2A -- -- -- -- -- -- -- V1 -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A -- -- -- -- -- -- -- -- -- -- -- V2 -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A 0.5 A 0.5 A 0.5 A 0.5 A -- -- -- -- -- -- -- V3 2A 2A 2A 2A 2A 2A 2A 2A 1A 1A 1A 1A 1A 1A 0.5 A 0.5 A 0.5 A 0.5 A -- -- -- -- -- -- -- I2C Adjustment Ranges*** 1.8-6.1 Ordering Note: 1. The cases and modules of both MP and IMP series can be interchanged to allow more flexibility. If intelligent modules are used with nonintelligent cases, a numeric code "4" is placed at the end of the module code (ex. 4LL0 becomes 4LL4). 2. USB to I2C module order code 73-769-001 Parallel Codes Slot 4 Slot 3 Slot 3 Slot 5 Slot 2 Slot 1 Rev. 10.09.08_77 IMP Series of 8 IMP4 available slots Slot 6 Slot 4 Slot 5 Slot 5 Slot 2 Slot 1 Slot 1 5.4-13.2 Slot 7 IMP8 available slots available slots Slot 6 Slot 4 Slot 3 12.6-22.0 7 6 54 3 Slot 2 IMP1 2 1 0 = no parallel 1=1&2 2=2&3 21.6-39.6 3=3&4 4=4&5 5=3&4&5 6=5&6 37.8-60.0 7=4&5&6 8=6&7 9 = 3 & 4, 6 & 7 Special Voltage - Consult Factory for specifications * Note: Increments of current not shown can be achieved by paralleling modules (add currents of each module selected). **Total output power on dual module must not exceed 144 W. *** For single ouput modules only. Ordering Information Module/Voltage/Option Codes First - Module Code Second - Voltage Code Third - Option Code Case Size Case Option Codes Software Code Hardware Code IMP1* Case Size (mm) 4 = 2.5" x 5" x 10"; 750 W-1100 W, 5 Slots (63.5 x 127 x 254) 8 = 2.5" x 7" x 10"; 1000 W-1200 W, 6 Slots (63.5 x 177.8 x 254) 1 = 2.5" x 8" x 11"; 1200 W-1500 W, 7 Slots (63.5 x 203.2 x 279.4) *Note: Add "E" after IMP4 to denote IEC input option. e.g. IMP4E (Not available on IMP8 or IMP1) - 3L0 - 2E2 - 1Q1 - 4LL0 Module Codes Module/voltage/option codes Module codes: (None) = 36 W triple O/P (1 slot) 1 = 210 W single O/P (1 slot) 2 = 360 W single O/P (2 slot) 3 = 750 W single O/P (3 slot) 4 = 144 W dual O/P (1 slot) 5 - 9 = future Voltage Codes: See Output Module Voltage/ Current table above Option Codes: 0 = Standard 1 = Module enable 2 = Constant current 3 = 1 & 2 combined 4 = Set for use in standard (non-intelligent case) 5 - 9 = Future 00 Case Option Codes First digit 0 - 9 = parallel code (See Parallel Codes table above) Second digit 0 = No options 1 = Reverse air 3 = Global enable 4 = Fan off w/inhibit 5 = Opt 1 + Opt 3 6 = Opt 1 + Opt 4 7 = Opt 3 + Opt 4 8 = Opt 1 +3 +4 9 = Future - A Software code used for configuration change. "A" is standard - ### Factory assembled for hardware of firmware mods. Embedded Power for Business-Critical Continuity Single IMP4 (AC input on opposite side) S L O T S L O T S L O T S L O T S L O T Rev. 10.09.08_77 IMP Series of 8 5 4 3 2 1 -A- Input 210 W IMP4 = 2.5" x 5" x 10" 5 available slots (63.5 x 127 x 254) 750 W max. 90-264 Vac 1100 W max. 180-264 Vac IMP8 and IMP1 AC input S L O T 7 S L O T 6 S L O T 5 S L O T 4 S L O T 3 S L O T 2 S L O T 1 Input IMP1 only 360 W IMP8 = 2.5" x 7" x 10" 6 available slots (63.5 x 177.8 x 254mm) IMP1 = 2.5" x 8" x 11" 7 available slots (63.5 x 203.2 x 279.4mm) N 1 Pin Connectors 1000 W max. 1200 W max. 85-264 Vac 1200 W max. 1500 W max. 180-264 Vac Figure 1. AC Input 2 3 ~ AC Input Pin No. 1 2 3 Pin No. 1 2 3 4 5 6 7 8 9 10 Pin No. 1 2 3 4 5 6 7 8 9 10 Function AC neutral AC line (hot) Chassis (earth) ground Function Input AC OK - "emitter" Input AC OK - "collector" Global DC OK - "emitter" Global DC OK - "collector" External Sync Global inhibit/optional enable logic "0" Global inhibit/optional enable logic "1" Global inhibit/optional enable return +5 VSB housekeeping +5 VSB housekeeping return Function No connection No connection No connection Serial clock signal (SCL) Serial data signal (SDA) Address bit 0 (A0) Address bit 1 (A1) Address bit 2 (A2) Secondary return (GND) 5 Vcc external bus (5 VCC. Bus) 1 N 750 W 2 3 ~ Figure 1. AC Input Dual Figure 1. AC Input PFC Input Connector (control and signals) Figure 2. Connector J1 1 1 6 5 5 10 6 Figure 2. Connector J1 10 Figure 2. Mates with Connector J1 Molex 90142-0010 Housing 90119-2110 Pin 144 W Triple Figure 3. Connector J 1 6 5 10 I2C Bus Output Connector Mates withConnector J2 Figure 3. Landwin 2050S1000 Housing 2053T011P Pin Connector Kit order # 73-841-023 36 W Embedded Power for Business-Critical Continuity Mechanical Drawings IMP Modules DC-DC Converter Output Modules Control Signal Information, J1 Control Connector Pin No. 1 2 3 4 5 6 7 8 9 10 Function + Remote Sense single or dual o/p main Remote Margin / V. Program single o/p Margin High single o/p N - Remote Sense / Margin Low single or dual o/p main 1 Spare 2 Module, Isolated Inhibit single or dual o/p 3 Module Inhibit return single or dual o/p Current Share (SWP) single or dual o/p main + Remote Sense V2 dual o/p, single is spare - Remote Sense V2 dual o/p, single is spare Figure 1. AC Input *Note: All IMP modules have a green DCOK LED. (except for 36 W module) Rev. 10.09.08_77 IMP Series of 8 Single 210 Watt .44" (11.2) 2X V+ (12.1) ~ .48" M4X8 SCREWS WITH CONICAL WASHER V- 1.38" (35.1) V ADJ .44" (11.4) PIN 1 DC OUTPUT CONNECTOR .32" (8.1) Figure 4. Connector J1 1 6 5 10 Single 750 Watt .63" (16.0) .59" (15.0) V+ Figure 2. Mates with Connector J1 Molex 90142-0010 Housing 90119-2110 Pin .48" (12.1) (2X) M 4 X 8 SCREWS WITH CONICAL WASHER 1.24"(11.0) (2X) .63" .33" (16.0) (8.5) V+ .61"(15.6) (2X) .44" (11.0) Single 360 Watt VPIN 1 1.38" (35.2) (2X) V ADJ .32" (8.1) PI D CO C O NN UTP EC UT TO R N 1 V AD J M (4 4X8 X) S C V- .44" (11.4) RE W S DC OUTPUT CONNECTOR .32" (8.1) Triple 36 Watt Dual 144 Watt .46 (11.7) (4X) V1 V2 + V2 M3X8 SCREWS WITH SPRING WASHER (4X) V2 ADJ V1 ADJ PIN 1 V1 + V1 ADJ V2 ADJ V1+ V2+ V1 + V1V2V3- V1 V2 + V2 V3 + V3 - .30 (7.5)(3X) V3+ V3 ADJ 1.17 (29.7) .42 (10.7) .32 (8.1) Mates with Molex 09-91-0600 Housing 26-60-5060 Pin Embedded Power for Business-Critical Continuity IMP Series IMP4 (750/1100 Watts Max) 5-Inch Case Size: IMP4: 2.5" x 5" x 10" (63.5mm x 127mm x 254mm) Weight: IMP4 Case: 3 lbs. * 360 W Single 1.0 lb. * 750 W Single: 1.6 lbs. 144 W Dual: 0.6 lb. Rev. 10.09.08_77 IMP Series of 8 Notes 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs. (0.67 N-m). (Optional IEC input connector) 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crIMP contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. J2 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Embedded Power for Business-Critical Continuity M4 MOUNTING HOLES (4X) IDENTICAL BOTH SIDES IMP Series IMP8 (1000/1200 Watts Max) 7-Inch Case Size: IMP8: 2.5" x 7" x 10" (63.5mm x 177.8mm x 254mm) Weight: IMP8 Case: 4.1 lbs. * 210 W Single: 0.6 lb. * 360 W Single: 1.0 lb. * 750 W Single: 1.6 lbs. 144 W Dual: 0.6 lb. Rev. 10.09.08_77 IMP Series 7 of 8 #8-32 MOUNTING HOLES (4X) MARKED AS Y 38.10 Normal Air Flow Reverse Air Flow 171.45 171.45 Notes 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crIMP contacts (Molex C - Grid III Series) Connector kit includes mating connector and 10 pins, Astec part #70-841-004. J2 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. xy xy Embedded Power for Business-Critical Continuity IMP Series IMP1 (1200/1500 Watts Max) 8-Inch Case Size: IMP1: 2.5" x 8" x 11" (63.5mm x 203.2mm x 279.4mm) Weight: IMP1 Case: 5.0 lb. * 210 W Single: 0.6 lb. Americas * 360 W Single: 1.0 lb. * 750 W Single: 1.6 lb. 5810 Van Allen Way * 144 W Dual: 0.6 lb. Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Rev. 10.09.08_77 IMP Series 8 of 8 Europe (UK) Normal Air Flow Reverse Air Flow Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com M4 MOUNTING HOLES (4X) IDENTICAL BOTH SIDES 171.45 techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 38.10 #8-32 MOUNTING HOLES (4X) MARKED AS Y 171.45 xy xy Emerson Network Power. The global leader in enabling business-critical continuity. AC Power 177.8 Connectivity DC Power Embedded Computing x 19.05 y xy M4 MOUNTING HOLES (4X) MARKED AS X Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co. Notes 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs (0.67 N-m). 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crIMP contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. J2 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. |
Price & Availability of IMP |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |