|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
100W Single Output with PFC Function Features : LPP-100 series Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) LPP-100-3.3 LPP-100-5 3.3V 20A 0 ~ 20A 66W 5V 20A 0 ~ 20A 100W 100mVp-p LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48 7.5V 13.5A 0 ~ 13.3A 101.25W 100mVp-p 12V 8.5A 0 ~ 8.5A 102W 100mVp-p 13.5V 7.5A 0 ~ 7.5A 101.25W 100mVp-p 15V 6.7A 0 ~ 6.7A 100.5W 100mVp-p 24V 4.2A 0 ~ 4.2A 100.8W 150mVp-p 27V 3.8A 0 ~ 3.8A 102.6W 150mVp-p 48V 2.1A 0 ~ 2.1A 100.8W 250mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p 3.14 ~ 3.63V 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 2.0% 0.5% 1.0% 28ms/230VAC 0.5% 1.0% 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 0.5% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 600ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load 28ms/115VAC at full load 120 ~ 370VDC PF>0.98/115VAC at full load 76% 79% 79% 80% 83% 83% 83% 0.75A/230VAC VOLTAGE RANGE Note.5 85 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) PF>0.95/230VAC 69% 1.7A/115VAC 75% COLD START 30A/230VAC <2mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 8.6 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 224.3Khrs min. MIL-HDBK-217F (25 222*62*32mm (L*W*H) 0.51Kg; 24pcs/13.9Kg/1.76CUFT ) OTHERS NOTE DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:LPP-100-SPEC 2008-03-25 100W Single Output with PFC Function Mechanical Specification 222 5 5 212 LPP-100 series Unit:mm CN2 1 62 52 CN1 5 4 3 2 1 F4A/250V +V ADJ. 8 43.5 AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 Assignment AC/L No Pin AC/N FG Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 2 max. 32 DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2,3,4 5,6,7,8 Assignment -V +V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Block Diagram PFC fosc : 67KHz PWM fosc : 134KHz PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER COSTANT CURRENT LIMITING & DETECTION CIRCUIT O.V.P. +V -V I/P EMI FILTER & RECTIFIERS FG O.L.P. PWM & PFC CONTROL Derating Curve Output Derating VS Input Voltage 100 Forced Air 3.3 ~ 7.5V With 18CFM (15cm) Forced Air Convection 3.3V ~ 7.5V With NO FAN 100 90 80 70 80 60 LOAD (%) 40 LOAD (%) 12 ~ 48V With No FAN 60 50 40 20 -10 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 115 135 155 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPP-100-SPEC 2008-03-25 |
Price & Availability of LPP-100 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |