|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TRUMPower DESCRIPTION 30-48 WATT MEDICAL & ITE SWITCHING POWER SUPPLIES TMC40 SERIES The TMC40 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 30-48 watts of continuous output power at convection cooling. They operate at 90-264 VAC input voltage without the need of voltage selection, and are suited for medical, information technology and industrial applications. Approval to both EN60601-1 and EN60950-1 safety standards improves design-in time and reduces end equipment compliance costs. FEATURES Medical and ITE approvals Compact size 2" x4" x1.18" Single, dual and triple outputs Full-range input 90-264 VAC Low earth leakage current Level B emissions RoHS compliant SAFETY STANDARD APPROVALS UL 2601-1 CSA C22.2 No. 601.1 TUV EN60601-1 INPUT SPECIFICATIONS Input voltage: Input frequency: Input current: Earth Leakage current: 90-264 VAC 47-63 Hz 0.9 A (rms) for 100 VAC 0.5 A (rms) for 240 VAC 150 A max. @ 264 VAC, 63 Hz GENERAL SPECIFICATIONS Switching frequency: Efficiency: Hold-up time: Line regulation: 625 KHz 80-88% typical except TMC40-T31-3 and TMC40-T31-5 at 75% typical 12 msec minimum at 110 VAC 0.5% maximum at full load 625 KHz 25 A @ 115 VAC, or 50 A @ 230 VAC, except 80-88% typical at 25 C cold start TMC40-T31-3 and 4000 VAC from input to output TMC40-T31-5 at 75% 1500 VAC from input to ground typical 500 VAC from output to ground MTBF: EMC Performance EN55011 / EN55022: FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: EN61000-4-11: Class B conducted, class B radiated Class B conducted, class B radiated Class B conducted, class B radiated Harmonic distortion, class A and D Line flicker ESD, 8 KV air and 6 KV contact Radiated immunity, 3 V/m Fast transient/burst, 2 KV Surge, 1 KV diff., 2 KV com. Conducted immunity, 3 Vrms Magnetic field immunity, 3 A/m Voltage dips, 30% reduction for 500 ms 60% reduction for 100 ms >95% reduction for 10 ms 400,000 hours at full load at 25 C ambient, calculated per MIL-HDBK-217F o o OUTPUT SPECIFICATIONS Output voltage/current: Maximum output power: Ripple and noise: Overvoltage protection: Overcurrent protection: Temperature coefficient: Transient response: See rating chart See rating chart 2% peak to peak on 5.0 V model, 1% peak to peak on other models. Provided on output #1 only; set at 112-132% of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04% /C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 s after a 25% step load change Inrush current: Withstand voltage: ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: -10 C to +70 C -40 C to +85 C 5% to 95% non-condensing o Derate from 100% to +50 C linearly to o 50% at +70 C o o o o Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com UNIVERSAL INPUT OUTPUT VOLTAGE/CURRENT RATING CHART Output #1 P/N TMC40-S05 TMC40-S12 TMC40-S15 TMC40-S24 TMC40-S48 TMC40-D23 TMC40-D25 TMC40-T31 TMC40-T31-3 TMC40-T31-5 TMC40-T32 TMC40-T39 Vnom. 5V 12 V 15 V 24 V 48 V +5 V +5 V +5 V +3.3 V +5 V +5 V +5 V Imin. 0A 0A 0A 0A 0A 0.5 A 0.5 A 0.5 A 0.8 A 0.5 A 0.5 A 0.5 A Imax. 8.0 A 3.5 A 3.0 A 2.0 A 1.0 A 6A 6A 6A 6A 6A 6A 6A Tol. 2% 2% 2% 2% 2% 3% 3% 3% 3% 3% 3% 3% +12 V +24 V +12 V +5 V +3.3 V +15 V +24 V Vnom. TMC40 MEDICAL & ITE SERIES Maximum Output Tol. Power 40 W 42 W 45 W 48 W 48 W 40 W 40 W 0.3 A 0.3 A 0.3 A 0.3 A 0.3 A 4% 4% 4% 4% 4% 40 W 30 W 30 W 40 W 40 W Output #2 Imin. (N/A) (N/A) (N/A) (N/A) (N/A) 0.1 A 0.1 A 0.1 A 0.1 A 0A 0.1 A 0.1 A 2A 1A 2A 2A 1.5 A 1.5 A 1A 5% 5% 5% 5% 5% 5% 5% -12 V +12 V +12 V -15 V -12 V Imax. Tol. Vnom. Output #3 Imin. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 0A 0A 0A 0A 0A Imax. NOTE: 1. Safety approvals are for PCB form only. To order unit with cover fitted, add suffix "C". MECHANICAL SPECIFICATIONS NOTES: 1. 2. 3. Dimensions shown in inches [mm] Tolerance 0.02 [0.5] maximum Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. Output connector mates with Moles housing 09-50-3061 and Moles 2878 series crimp terminal. Ground tab is 0.25 [6.35] x 0.032 [0.8] To ensure compliance with level B emissions, connect the two "" marked mounting holes with metallic standoffs to chassis. Weight: 205 grams (0.45 lbs.) approx. 4. 5. 6. 7. PIN CHART PIN 1 MODEL TMC40-S05 TMC40-S24 TMC40-D23 TMC40-T31 TMC40-S12 TMC40-S48 TMC40-D25 TMC40-T32 TMC40-T39 TMC40-S15 2 3 4 5 6 +V1 +V1 RTN RTN N.C N.C +V1 +V1 +V1 +V1 +V1 +V1 RTN RTN RTN RTN RTN RTN N.C -V3 +V3 +V2 +V2 +V2 TMC40-T31-3 ,TMC40-T31-5 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com |
Price & Availability of TMC40 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |