![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
G200RW Series Compact MiniDIP, 2W Wide Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: * 2W Output Power * 2:1 Input Voltage Range * 1,500 VDC Isolation * Short Circuit Protected * Compact MiniDIP Case * Single & Dual Outputs * 1.0 MH MTBF * Industry Standard Pin-Out Input Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. 5 VDC Input 3.5 12 VDC Input 4.5 24 VDC Input 8.0 48 VDC Input 16.0 (Pi) Filter Typ. 4.0 7.0 12.0 24.0 Max. 4.5 9.0 18.0 36.0 1.0 1,500 Units VDC A mW Units % % % % mV P - P mV P - P mV rms % Sec % %/C Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Response Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Min. Typ. 1.0 1.0 0.3 0.5 30 Max. 2.0 2.0 0.5 0.75 50 75 15 300 5.0 0.02 Vin = Min to Max Iout = 25% to 100% Over Line, Load & Temp. 120 50% Load Step Change RoHS Compliant 100 3.0 0.01 Continuous (Autorecovery) Min. 1,500 1,650 1,000 Typ. General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds Flash Tested For 1 Sec 1,000 VDC 100 kHz, 1V Max. Units VDC VDC M pF kHz Units C C C % 250 300 420 Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. -40 +25 -40 +25 -40 Free Air Convection RH, Non-condensing Ambient Case Max. +65 +90 +125 95 MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Physical Case Size Case Material Weight 0.94 x 0.54 x 0.30 Inches (23.8 x 13.7 x 7.62 mm) Non-Conductive Black Plastic (UL94-V0) 0.18 Oz (5.1g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. 1,000 Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units kHours Units VDC C mW Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Typ. Max. 11.0 25.0 50.0 100.0 260 1,800 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number G201RW G202RW G203RW G204RW G205RW G206RW G207RW G211RW G212RW G213RW G214RW G215RW G216RW G217RW G221RW G222RW G223RW G224RW G225RW G226RW G227RW G231RW G232RW G233RW G234RW G235RW G236RW G237RW Input Output Reflected Efficiency Voltage (VDC) Current (mA) Ripple Voltage Current Current (%, Typ) Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) Current (mA) 5 4.5 - 9.0 471 40 3.3 500.0 125.0 100 70 5 4.5 - 9.0 548 40 5.0 400.0 100.0 100 73 5 4.5 - 9.0 534 40 12.0 1670 42.0 100 75 5 4.5 - 9.0 582 40 15.0 134.0 33.0 100 73 5 4.5 - 9.0 667 40 5.0 200.0 50.0 100 64 5 4.5 - 9.0 615 40 12.0 83.0 21.0 100 69 5 4.5 - 9.0 598 40 15.0 67.0 17.0 100 71 12 9.0 - 18.0 184 20 3.3 500.0 125.0 25 73 12 9.0 - 18.0 217 20 5.0 400.0 100.0 25 77 12 9.0 - 18.0 209 20 12.0 1670 42.0 25 80 12 9.0 - 18.0 220 20 15.0 134.0 33.0 25 80 12 9.0 - 18.0 242 20 5.0 200.0 50.0 25 73 12 9.0 - 18.0 224 20 12.0 83.0 21.0 25 78 12 9.0 - 18.0 226 20 15.0 67.0 17.0 25 78 24 18.0 - 36.0 96 10 3.3 500.0 125.0 15 72 24 18.0 - 36.0 109 10 5.0 400.0 100.0 15 77 24 18.0 - 36.0 109 10 12.0 1670 42.0 15 80 24 18.0 - 36.0 108 10 15.0 134.0 33.0 15 81 24 18.0 - 36.0 119 10 5.0 200.0 50.0 15 74 24 18.0 - 36.0 112 10 12.0 83.0 21.0 15 78 24 18.0 - 36.0 110 10 15.0 67.0 17.0 15 80 48 36.0 - 72.0 49 8 3.3 500.0 125.0 10 71 48 36.0 - 72.0 57 8 5.0 400.0 100.0 10 73 48 36.0 - 72.0 53 8 12.0 1670 42.0 10 79 48 36.0 - 72.0 55 8 15.0 134.0 33.0 10 79 48 36.0 - 72.0 62 8 5.0 200.0 50.0 10 71 48 36.0 - 72.0 57 8 12.0 83.0 21.0 10 77 48 36.0 - 72.0 57 8 15.0 67.0 17.0 10 77 Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 250 250 250 250 250 250 250 120 120 120 120 120 120 120 Notes: 1. When measuring output ripple, it is recommended that an external 0.47 F ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 F capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure startup. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 8.2 F is recommended, for 12V input units, a 3.3 F; and for 24V & 48V units a 1.5 F. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Derating Curve Mechanical Dimensions Capacitive Load Output (VDC) 3.3 5.0 12.0 15.0 5.0 12.0 15.0 F Max 2,200 1,000 170 110 470 100 47 Pin Connections Pin 1 7 8 9 10 16 Single -Vin NC NC +Vout -Vout +Vin Dual -Vin NC Common +Vout -Vout +Vin Note: For dual output units, Cap load is given for each output. NC = No Connection Mechanical Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25) MicroPower Direct www.micropowerdirect.com * 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 * FAX: (781) 344-8481 * E-Mail: sales@micropowerdirect.com |
Price & Availability of G233RW
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |