 12W DC-DC Regulated Single Output Converter
Features :
SCW12
series
2:1 wide input range 1500VDC I/O isolation Built-in remote ON/OFF control Built-in EMI filter Protections: Short circuit / Overload Cooling by free air convection Five-sided shield metal case 100% full load burn-in test Low cost / High reliability Modified models available: output 2.5V/3.3V 2 years warranty
SPECIFICATION
ORDER NO. DC VOLTAGE CURRENT RANGE RATED POWER OUTPUT
SCW12A-05 SCW12B-05 SCW12C-05 SCW12A-12 SCW12B-12 SCW12C-12 SCW12A-15 SCW12B-15 SCW12C-15
5V 480 ~ 2400mA 12W
12V 200 ~ 1000mA 60mVp-p
15V 160 ~ 800mA 60mVp-p
RIPPLE & NOISE (max.) Note.2 50mVp-p LINE REGULATION Note.3 0.5% LOAD REGULATION VOLTAGE ACCURACY SWITCHING FREQUENCY VOLTAGE RANGE EFFICIENCY (Typ.)
Note.4
0.5% 2.0% 400KHz min. A: 9 ~ 18VDC 82% Full load No load Pi network Fuse recommended 110 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +71 (Refer to output load derating curve) B: 18 ~ 36VDC 83% A: 70mA 84% B: 35mA C: 36 ~ 72VDC 82% C: 320mA C: 25mA 83% 83% 82% 85% 83%
INPUT
DC CURRENT FILTER PROTECTION OVERLOAD
A: 1245mA B: 625mA
PROTECTION
(Note. 5)
SHORT CIRCUIT WORKING TEMP. WORKING HUMIDITY
ENVIRONMENT
20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -25 ~ +105 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05% / (0 ~ 50 ) VIBRATION WITHSTAND VOLTAGE 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1.5KVDC I/P-O/P: 100M Ohms / 500VDC / 25 2200pF max. / 70% RH
SAFETY
ISOLATION RESISTANCE ISOLATION CAPACITANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 Class A, FCC part 15 Class A Compliance to EN61000-4-2,3,4,5,6,8 light industry level, criteria A EMS IMMUNITY Power ON: R.C. ~ -Vin > 4VDC or open ; Power OFF: R.C. ~ -Vin < 1VDC or short REMOTE CONTROL OTHERS MTBF DIMENSION WEIGHT 600Khrs min. MIL-HDBK-217F(25 ) 31.8*20.3*12.2mm or 1.25"*0.80"*0.48" inch (L*W*H) 18.5g
Mechanical Specification
Unit:mm(inch)
20.3(0.80)
1 2
Pin Configuration
Derating Curve
0.6
+ 0.2/-0 2.54( 0.10 ) 3.81(0.15)
Pin No.
1 2&3 9 11 14 16 22 & 23
Output
R.C. - Vi n N.C. N.C. + Vo u t - Vo u t + Vi n
100
17.8(0.70)
22
3
BOTTOM VIEW
16 14 9
2.54( 0.10 )
SIDE VIEW
31.8(1.25)
LOAD (%)
23
60
5.08( 0.20 )
11
15.24(0.60)
12.2(0.48)
-25
0
25
50 60 71
100
Ta (
NOTE 1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 20% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
)
File Name:SCW12-SPEC 2008-10-22


▲Up To Search▲   

 
Price & Availability of SCW12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X