Datasheet File OCR Text: |
155 Mbps Bi-directional SC Receptacle Single Fiber Transceiver B-13/15-155-T(3)-SSC 4 Features * Diplexer Single mode, Single Fiber 1x9 SC Receptacle Connetor * Wavelength Tx 1310nm/Rx 1550 nm * SONET OC-3 SDH STM-1 Compliant * Single +5V Power Supply (B-13/15-155-T-SSC4) * Single +3.3V Power Supply (B-13/15-155-T3-SSC4) * PECL/LVPECL Differential Inputs and Outputs * Wave Solderable and Aqueous washable * LED Multisourced 1x9 Transceiver Interchangeable * Class 1 Laser Int. Safety Standard IEC 825 Compliant * Uncooled Laser Diode with MQW structure * Complies with Telcordia (Bellcore) GR-468-CORE * Temperature Range: 0 to 70C * Optical Isolation > 30 dB * Cross Talk < -33 dB Absolute Maximum Rating Parameter Power Supply Voltage Power Supply Voltage Input Voltage Output Current Soldering Temperature Storage Temperature Symbol Vcc Vcc Iout - Min. 0 0 0 -40 Max. 6 3.6 Vcc 30 260 85 Unit V V V mA C C Note B-13/15-155-T-SSC4 B-13/15-155-T3-SSC4 10 seconds on leads only Tstg Recommended Operating Condition Parameter Power Supply Voltage Power Supply Voltage Operating Temperature Data rate Symbol Vcc Vcc Topr Min. 4.75 3.1 0 Typ. 5 3.3 155 Max. 5.25 3.5 70 Unit V V C Mbps Transmitter Specifications, (0C 1 155 Mbps Bi-directional SC Receptacle Single Fiber Transceiver B-13/15-155-T(3)-SSC 4 Transmitter Specifications, (0C 155 Mbps Bi-directional SC Receptacle Single Fiber Transceiver B-13/15-155-T(3)-SSC 4 Connection Diagram 1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TD-) 8. (TD+) 9. (Tx GND) NC Top View NC Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data in Transmitter Signal Ground PIN 1 2 3 4 5 6 7 8 Warnings 9 Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal Dc power for the receiver section Dc power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane Legal Notice 3 155 Mbps Bi-directional SC Receptacle Single Fiber Transceiver B-13/15-155-T(3)-SSC 4 Recommended Circuit Schematic B-13/15-155-T-SSC4 Tx Vcc 82R 82R Rx Vcc R1 R9 TD+ TD130R 130R 82R R5 82R 82R C5 987654321 82R 82R R3 82R R7 82R 82R C6 R2 130R 130R R4 No internal connection No internal connection R10 Notes: R1=R3=R5=R7=R9=82 R2=R4=R6=R8=R10=130 C1=C2=C3=C5=C6=0.1 F C4=10 F L1=L2=1 H Transceiver Top view 130R 130R 130R Tx Vcc Rx Vcc RD+ RDSD 130R 130R 130R R8 R6 Rx Vcc C1 L1 Vcc C3 L2 Tx Vcc C2 C4 The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. Recommended Circuit Schematic B-13/15-155-T3-SSC4 The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. 4 155 Mbps Bi-directional SC Receptacle Single Fiber Transceiver B-13/15-155-T(3)-SSC 4 Package Diagram Diplexer Transceiver Assembly (Receptacle Type) Top View Front View x8 Side View Rear View 5 155 Mbps Bi-directional SC Receptacle Single Fiber Transceiver B-13/15-155-T(3)-SSC 4 Ordering Information B -13/15 - 155 -T(3) - S SC 4 * Tx Wavelength = 1310 nm Rx Wavelength = 1530 nm * Communication protocol (155 Mbps) * 5V /3.3V Transceiver * Single mode fiber * Connector options Warnings Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notice IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at Luminents sole and absolute discretion. Luminent warrants performance of its products to current specifications only in accordance with the companys standard one-year warranty; however, specifications designated as "preliminary" are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the companys Terms and Conditions of Sale for further warranty information. Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. Customer agrees that Luminent is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. (c) Luminent, Inc. 2003 All rights reserved 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 * LUMINENT.COM LUMNDS608-0603 6 |
Price & Availability of B-13-15-155-T-SSC4 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |