![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, - or 3-pole 2-polestandardversion 3-poletypewithoutfrontbezel/knob standardfrontbezel/knob Description - Thermalcircuitbreaker1-,2-or3-pole - Supplementaryprotectorforgeneralindustrialuse - Positivelytrip-freerelease - Bezel/knobsnap-on - Easyactuationwithgloves - Frontelementscanbedonebycustomer Applications - Highpressurecleaners - Floorcleaningequipment - Powertools - Woodandstoneworkingmachines - Equipmentforbuildingconstruction - Industrialequipment - Commercialkitchenappliances Standards - IEC60934 - UL1077 - CSAC22.2235 - GB17701 Weblinks Approvals:http://www.schurter.com/approvals RoHS:http://www.schurter.com/rohs Technical Data Rated voltage Ue 1-pole 2-pole 3-pole Rated current In 1- / 2-pole 3-pole 1- / 2-pole, AC 240 V 3-pole, AC 415 V Accessible range Terminal side 50 Hz Impulse 1.2/50 s DC 500 V AC 240 V / 50/60 Hz DC 32 V AC 240 V / 50/60 Hz DC 60 V AC 415 Y/240 V / 50/60 Hz 0.05 - 20 A 0.05 - 12 A 0.05...20 A: 2000 A, SC (C1) 0.05...12 A: 2000 A Shock resistance Degree of protection IP 40 IP 00 > 2500 V > 4000 V > 100 MOhm Max. switching capacity 1-, 2-pole for switch only types 3-pole (without bimetal) 20 A 12 A Type of tripping Weight 1-pole 2-pole 3-pole Overload IEC 60934 UL 1077 min. 40 cycles @ 6 x In, cos phi 0.6 min. 50 cycles @ 1.5 x In, cos phi 0.75 (OLO) -30 C to +60 C Admissible ambient air temperature Resistance to vibration IEC 60068-2-6, Test Tc Conditional short circuit Inc 10...60 Hz: 0.75 mm 60...500 Hz: 10 G IEC 60068-2-27, Test Ea 30 G / 18 ms Thermal positively trip free 45 g 60 g 75 g Dielectric strength Insulation resistance Endurance (typical) Mechanical 50'000 cycles AC: 1 x In, cos phi 0.6 50'000 cycles DC: 1 x In, L/R = 2...3ms 50'000 cycles circuit breakers TA35 www.schurter.com/pg17_18_19 Tripping Characteristics [ min ] [ sec ] 10'000 Type Rated current TA35 <3 A (TC-1) 1, 2 pole 3 pole Ambient temp. +23 C [ min ] [ sec ] 10'000 Type Rated current TA35 >3-20A (TC-1) (3 pole, max. 12A) 1,2,3 pole Ambient temp. +23 C 60 30 20 10 5 200 100 1 50 2000 1000 500 60 30 20 10 5 200 100 1 50 2000 1000 500 20 10 5 2 1 0,5 Tripping time 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ] 20 10 5 2 1 0,5 Tripping time 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ] TheabovetrippingcharacteristicsapplytosymmetricaloverloadsonallpolesontheTA35only. Atasymmetricoverloadsonmulti-poletypes,thetrippingcharacteristicwillchange. - Ifa2-poletypeTA35isloadedatonepoleonly,thetrippingcurrentwillbeshiftedbyfactor1.05(TC-2). - Ifa3-poletypeTA35isloadedatonepoleonly,thetrippingcurrentwillbeshiftedbyfactor1.10(TC-2). Tomeettheabovetrippingcharacteristicatasymmetricoverloadsonmulti-poletypes,thevalueoftheratedcurrentoftheCBEhastobemultiplied bythefactormentionedabove. Effect of ambient temperature Theunitiscalibratedforanambienttemperatureof+23C.To determinetheratedcurrentforlowerorhigherambienttemperature, useacorrectionfactorfromthetablebelow. Ambient temperature[C] -30 -20 0 +23 +40 +50 +60 Correctionfactor 1-pole 0.77 0.81 0.90 1.00 1.03 1.04 1.06 2-pole 0.76 0.81 0.90 1.00 1.03 1.04 1.06 3-pole 0.76 0.81 0.90 1.00 1.06 1.10 1.14 Example for -pole type: Ratedcurrentat+23C Ambienttemperature Correctionfactor Chosenratedcurrentat+40C ambienttemperature: 5.0A +50C 1.04 5 A x 1.04 = 5. A circuit breakers 3 circuit breakers Standard rated currents and typical internal resistance Code Z05 J01 J05 J10 J15 J20 J25 J28 030 040 050 060 070 080 100 120 140 150 160 180 200 In[A] 0.05 0.1 0.5 1.0 1.5 2.0 2.5 2.8 3.0 4.0 5.0 6.0 7.0 8.0 10.0 12.0 14.0 15.0 16.0 18.0 20.0 Ri[W] 200.0 70.0 2.750 0.720 0.340 0.187 0.115 0.089 0.059 0.059 0.044 0.028 0.0142 0.0142 0.0109 0.0086 0.0072 0.0056 0.0056 0.0052 0.0052 unprotectedpoles(withoutbimetal)2.2mW Approvals #ofpoles UL UL 1077 1 2 3 UL CSA C22.2 235 1 2 3 VDE IEC 60934 1 2 3 CQC GB 17701 1 2 3 Ratedcurrents 0.05...20 A 0.05...20 A 0.05...12 A 0.05...20 A 0.05...20 A 0.05...12 A 0.05...20 A 0.05...20 A 0.05...12 A 0.05...20 A 0.05...20 A 0.05...12 A RatedvoltageAC 240 V 240 V 415 Y/240 V 240 V 240 V 415 Y/240 V 240 V 240 V 415 Y/240 V 240 V 240 V 415 Y/240 V RatedvoltageDC 32 V 60 V -- 32 V 60 V -- 32 V 60 V -- 32 V 60 V -- Actualinformationaboutapprovalscanbefoundon:www.schurter.com/approvals. 4 circuit breakers TA35 www.schurter.com/pg17_18_19 Order Code Number of switched poles Number of protected poles 1-pole 0 LINE P1 1 LINE P1 0 P1 -pole 1 LINE P2 P1 3-pole P2 P1 0 LINE P2 3 LINE P2 P3 P1 LINE P1 LINE P2 P3 4 4 5 6 7 LOAD LOAD 4 4 5 LOAD LOAD 8 7 8 9 7 LOAD 8 LOAD LOAD Basic type EFC EFT EBC EBT EBD EKC EKD Other versions on request TA35- EBT T F 10 C0 Noother features Frontbezel and actuation knob Bezel T N black without bezel Knob black without knob Without thermal overload protection: code C00 With thermal overload protection: rated current In (A) In Code Z05 J01 J0 J03 J04 J05 J08 In 1.0 1.2 1.5 2.0 2.5 3.0 3.5 Code J10 J1 J15 J0 J5 030 035 In 4.0 5.0 6.0 7.0 8.0 10.0 12.0 Code 040 050 060 070 080 100 10 In 14.0 15.0 16.0 18.0 20.0 Code 140 * 150 * 160 * 180 * 00 * 0.05 0.1 0.2 0.3 0.4 0.5 0.8 Bezel marking Surface F N relief recessed no marking Symbol I0 no marking 0ther rated currents on request. * 3-pole max. 12A circuit breakers 5 circuit breakers Dimensions TA35 1-pole 49.6 19.2 13.7 2 39 40 15 1 47 o 3.4 o 24 24.5 55.6 2 7 4 P1 2.3 21.3 10.6 7.1 33.8 5.9 39 6.3 x 0.8 mm 18.2 ScrewType:2xPTWN1413KA35x12 TA35 -pole 49.6 30.2 13.7 2 39 40 15 1 47 o 3.4 55.6 o 24 24.5 LINE 2 7 4 P1 10.6 5.9 7.1 11 2.3 21.3 6.3 x 0.8 mm 33.8 39 ScrewType:2xPTWN1413KA35x12 TA35 3-pole 49.6 41.2 13.7 2 39 40 15 1 47 o 3.4 55.6 o 24 24.5 LINE 47 7 4 P1 2 10.6 5.9 7.1 11 11 2.3 21.3 6.3 x 0.8 mm 33.8 39 ScrewType:2xPTWN1413KA35x12 6 circuit breakers LINE TA35 www.schurter.com/pg17_18_19 Front bezel/knob 52 o 38 Switching angle (38.2 - 41.2) 18 OFF R3 35 ON 2-3 Cut-out 40 25 4 20 20 o 8.4 Mounting instructions Customerspecificbezels/actuatordesignspossible 90 circuit breakers 7 |
Price & Availability of TA35-EFCTN100
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |