![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
DIGITAL HiTESTER 3239 (4-terminal function) 3238 (Advanced model) 3237 (Economically priced) Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed DMM The DIGITAL HiTESTERs 3237, 3238, and 3239 can perform 3.3 ms high-speed sampling, and come equipped with a comparator, external input and output, and an RS-232C interface. These three highperformance DMMs can be used not only in laboratories, but in production lines that require the minimal tact time. The 3237 is the basic model, and is equipped with the basic necessary functions. The 3238 is a highprecision, broadband model that also features current measurement terminals and a frequency measurement function. The 3239 includes the functions of the 3238 plus the 4-terminal resistance measurement function. All three units are designed with emphasis on measurement speed and safety. 1 3.3 ms/sample High-speed Performance and Reliability Features Sampling speed Values in the ( ) show samples/second. Frequency 50 Hz 60 Hz FAST* MEDIUM SLOW 3.3 1 ms (300) 130 5 ms (8) 1,040 50 ms (1) 3.3 1 ms (300) 108 5 ms (9) 1,080 50 ms (1) Samples at rates of up to 300 samples/sec. (3.3 ms/sample) Comparator function provides high-speed pass/fail evaluation Equipped with external input and output for sequence control Usefull Save/Load function helps work go faster The 3237, 3238 and 3239 are equipped with a variety of functions that help minimize tact time in production lines. For details, see page 2. Does not apply at resistances higher than 2M, or LP higher than 200k (see page 5). For the 3238 and 3239's frequency function gate time, see page 5. * Approximately 55 ms required for self-calibration at 30-minute intervals. True RMS value measurement Both the 3237 and 3238 use true RMS measurement for determination of distorted waveforms. In fact, HIOKI guarantees accuracy of the 3238 and 3239 for AC voltage of 10 Hz to 300 kHz, and AC current of 10 Hz to 30 kHz. For specifications, see pages 5 and 6. Low power resistance measurement function prevents sample deterioration The 3237, 3238 and 3239 use a low power function to minimize sample degradation when measuring resistance. With this function, open terminal voltage never goes over 0.45 V DC, and measurement current never surpasses 100 A DC. For specifications, see pages 5 and 6. Interface supports full remote operation Measurement can be automated by using a controller to operate the 3237 or 3238 through the GP-IB or RS-232C interface. For details, see page 3. Select from 3 types of units The basic and economical 3237 32 37 32 38 32 39 The high-accuracy & multi-functional 3238 3239 DC V basic accuracy: 0.025% rdg.2dgt. DC V basic accuracy: 0.01% rdg.2dgt. Includes frequency measurement for AC and DC A DC voltage AC voltage [5 ranges, 199.999 mV to 1000.00 V] [4 ranges, 1999.99 mV to 700.00 V] 2-terminal [7 ranges, 199.999 to 100.000 M] 2-terminal [4 ranges, 1999.99 to 1999.99 M] For 4-terminal resistance measurement Resistance DC V basic accuracy: 0.01% rdg.2dgt. All the functions of the 3238, plus 4-terminal measurement Reliable resistance measurement using the 4-terminal measurement method Using 4-terminal resistance measurement, which is unaffected by variables such as measurement lead wiring resistance, the 3239 displays outstanding resistance measurement capabilities. Resistance LP Continuity check Diode check [A buzzer sounds when resistance is less than 50.00 ] [Anode-cathode voltage in the 1999.99 mV range] Current measurement by clamp sensor AC/DC current Frequency 4-terminal 4-terminal [2 ranges, 199.999 mA and 1999.99 mA] [5 ranges, 99.9999 Hz to 300.000 kHz] Resistance [5 ranges,199.999 to 1999.99 k] Resistance LP [4 ranges,1999.99 to 1999.99 M] For clamp specifications, see page 4 For DIGITAL HiTESTER specifications, see pages 5 and 6 2 Minimizing tact time with sequence control High-speed comparator and external input/output Connector used: 57RE-40360-730B (D29) (DDK Ltd.) EXT.I/O Loading of saved settings from panel......LOAD 0 to 4 Measurement start trigger input............TRIG Measurement end signal output............EOC Comparator output..............................Hi, IN, Lo Internal power supply +5 V (max. 50 mA)......INT. DC V Internal GND........................................INT. GND Comparator with external output You can set the upper and lower limits, and display one of 3 results: Hi, IN or Lo. In addition to LED and buzzer results, open collector output results are provided through the external input/output terminals. X: measurement value, H: Upper limit, L: Lower limit X > H..............................Hi H > X > L.....................IN L > X..................Lo Conforming connector: ADS-HC360001-010 (Honda Tsushin Kogyo Co., Ltd.), RC30-36P (Hirose Electric Co., Ltd.) and other suitable connectors Input type: CMOS level Signal voltage: Hi 3.8 V to 5.0 V, Lo 0 V (shorted) to 1.2 V Logic: Negative logic (Low active) Output type: Open collector Applied voltage: Max. 35 V DC, 50 mA Logic: Negative logic (Low active) With free running measurement MIN. Time TYP. ... See below MAX. ... With external control T1 Measurement trigger pulse width 500 s T2 T3 T4 Trigger delay time Sampling time using external control FAST See the table MEDIUM at the top right of page 1. SLOW ... 2.0 ms ... ... ... Internal operation time the of measurement 500 s T5 Fromuntil end next trigger the ... 1.7 ms ... EOC Lo level time FAST 50 ms ... T6 for free running MEDIUM ... measurement SLOW ... 500 ms ... FAST Sampling time See the table T7 for free running MEDIUM at the top right of page 1. measurement SLOW Save/Load function for rapid response to various work situations You can save and recall a maximum of 30 DMM setting conditions for various range and comparator values. A trigger delay designed for measurement safety The 3237, 3238 and 3239 are equipped with a trigger delay function that can be set to manual or automatic for the time period between trigger input and the display of the comparator result (see T2 in the figure above). Manual settings: Designate periods in terms of millisecond intervals between 0.000 s and 9.999 s Automatic settings: FAST MEDIUM SLOW DC V AC V (200 to 200 k) 3 ms 500 ms 3 ms 3 ms 800 ms 3 ms 3 ms 1.5 s 3 ms 3 Automation of Line Inspection Available interfaces GP-IB (option -01 specifications) Purpose: Remote control and measurement value output Standards conformance : IEEE -488.1 1987 Reference standard Transmission speed (reference data) Power line frequency: 60Hz TRIG: EXT.Trig Command: [:READ ?] RS-232C (standard) Purpose: Remote control and measurement value output Transmission system Transmission speed Data bit length Stop bits Parity bits Delimiter Handshaking XON/XOFF Connector : Asynchronous method Full duplex : 9600 bps (fixed) : 8 bits :1 : None : CR+LF : Hardware : Not used : 9-pin D-sub connector : IEEE -488.2 1987 FAST MEDIUM SLOW Transmission 1,080 7.0 ms 108 ms ms speed Controller: PC-9801 RA (NEC) OS: MS-DOS Ver. 3.30, N88-BASIC Ver. 6.0 Interface function: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, CO User code User connector : ASCII code : 24-pin IEEE488 interface bus connector All functions except switching the power on and off can be completely remote controlled and measurement data collected via either the GP-IB or RS-232C interface Please inquire regarding compatibility with the command sets of other manufacturers. Output data to a printer (option) When an RS-232C compatible PRINTER 9442 is connected, you can print measurements by pressing the key if in manual trigger mode, or the key if in internal trigger (free run) mode. Item No. Judgment PRINTER 9442 CONNECTOR CABLE 9444 Cord length approx 1.5m AC ADAPTER 9443 Measurement function Measurement value 9443-02 9443-01 (For the EU) (For Japan) 9443-03 (For the America) Equipped with a foot switch for printer control As an alternative to pressing the key or the key, you can also connect a foot switch to the external I/O TRIG terminal. You can then initiate printing by stepping on the foot switch (closing the circuit). : Thermal serial dot matrix number suffix when ordering. : 112 mm : 52.5cps : AC ADAPTER 9443 or supplied nickel-hydride battery (capable of printing about 3000 lines on full charge from 9443) Dimensions and mass : Approx. 160W 66.5H 170D mm; approx. 580 g Printing method Paper width Printing speed Power supply Please specify appropriate model When you purchase a PRINTER 9442, you must also purchase a CONNECTION CABLE 9444 and a AC ADAPTER 9443 to connect it to the DMM. 4 Efficient Evaluation Testing PC measurement using the high accuracy and broad coverage of the 3238 and 3239 Time Current Integration Example of data processing with Microsoft Excel Time History Graph of Current Integration Time Battery Discharge Characteristics Highly accurate measurement with minimal drift The unit uses self-regulation to suppress drift. Also, the DMM is ideal for collecting data over extended periods of time. Using Excel for efficient data processing The DMM supports fast data processing by allowing you to transfer data directly to a worksheet through either the GP-IB or RS-232C interface. Consult your nearest HIOKI dealer for details on software Supports large AC current measurement by clamp sensor Easy setup Both the 3237, 3238 and 3239 can measure live line currents using an optional clamp sensor. Enter the name of the clamp sensor being used and display current values simply by selecting a range. Clamp sensor settings screen Select 9010 Select the 20 A range. From the menu's clamp sensor selection screen, select the name of the sensor with the cursor key and press the key. Then, select the same range as you set for the sensor with the cursor key. * The accuracy of the clamp sensors shown on the left (when used with the DMM) is calculated by taking: the difference in the AC V accuracy for the DMM (dgt.) 10 (dgt.). For the AC V accuracy of the DMM, see page 6. In addition to the sensors described above, you can also connect the 3283, 3284, 3285 (requires the 9094) Clamp On HiTesters, and the 9277, 9278, 9279 (requires the 9555) DC Sensors. 5 3237, 3238, 3239 common specifications (Accuracy at 23C5C (73F9F), 80% rh or less) DC voltage (DC V) Range Resolution Full scale Input impedance Overload protection 200 mV 1 V 199.999mV Greater than 100M 1000 V DC 2000 mV 10 V 1999.99mV Greater than 100M 750 V AC 20 V 100 V 19.9999 V Appox. 11 M However, less than 200 V 1 mV 199.999 V Appox. 10 M 107 V Hz 1000 V 10 mV 1000.00 V Appox. 10 M Resistance () 2-terminal measurement Range Resolution Full scale Current Open terminal voltage Overload protection 200 1 m 199.999 Appox. 1 mA 6V DC max. 2000 10 m 1999.99 Appox. 1 mA 6V DC max. 20 k 100 m 19.9999k Appox. 100A 6V DC max. 200 k 1 199.999k Appox. 10A 6V DC max. 500Vpeak 2000 k 10 1999.99k Appox. 1 A 6V DC max. 20 M 100 19.9999M Appox. 100nA 6V DC max. 100 M 1 k 100.000M Appox. 20nA 6V DC max. For fast sampling in the 20 M range or higher. Frequency FAST* For sampling at in the 2 M range or the LP 200 k.range or higher AC voltage (AC V) Range Resolution Full scale 2000 mV 10 V 1999.99mV 20 V 100 V 19.9999 V 200 V 1 mV 199.999 V 700 V 10 mV 750.00 V Input impedance Overload protection Appox. 1 M 600 V DC Appox. 1 M 750 V rms, 1000Vpeak Appox. 1 M However, less than 107 V Hz Appox. 1 M Resistance () at Low Power function 2-terminal measurement Range Resolution Full scale 2000 10 m 1999.99 20 k 100 m 19.9999k 200 k 1 199.999k 2000 k 10 1999.99k Continuity check Range Resolution Full scale Current Open terminal voltage Overload protection 2000 10 m 1999.99 Appox. 100A 0.45V DC max. 500 Vpeak A built-in buzzer sounds when the resistance value is less than 50.00 . Current Open terminal voltage Overload protection Appox. 100A 0.45V DC max. Appox. 10A 0.45V DC max. 500Vpeak Appox. 1 A 0.45V DC max. Appox. 100nA 0.45V DC max. MEDIUM SLOW Frequency FAST* 50 Hz 20 1 ms 170 5 ms 1,360 50 ms 60 Hz 16.7 1 ms 142 5 ms 1,420 50 ms * Approximately 55 ms required for self-calibration at 30-minute intervals. 50 Hz 20 1 ms 60 Hz 16.7 1 ms Diode check Range Resolution Full scale Current Open terminal voltage Overload protection 2000 mV 10 V 1999.99mV Appox. 1 mA 6V DC max. 500 Vpeak 3238, 3239 specifications (Accuracy at 23C5C (73F9F), 80% rh or less) AC/DC current (A) Range Resolution Full scale Internal resistance Overload protection 200 mA 1 A 199.999mA Appox. 1 250V, 2A fuse 2000 mA 10 A 1999.99mA Appox. 100 m AC current (AC A) 200mA range Accuracy %, ppm=reading error, d=digit error Range Frequency DC current (DC A) Accuracy %, ppm=reading error, d=digit error Range 200 mA 2000 mA Thermal coefficient 0.1 %20d 400ppm20d 300ppm10d 300ppm10d 300ppm10d 500ppm30d 0.1 %30d Sampling SLOW 0.1 %6d 0.15%6d MEDIUM 0.1 %10d 0.15%10d FAST 0.1 %300d 0.15%300d Thermal coefficient 100ppm0.6d 150ppm0.6d Thermal coefficient 0.12%20d 600ppm20d 400ppm10d 400ppm10d 600ppm20d 0.12%30d undefined AC current (AC A) 2000mA range Accuracy Sampling SLOW 1.0%200d 0.4%200d 0.3%100d 0.3%100d 0.3%100d 0.5%300d 1.0%300d MEDIUM undefined undefined 0.5%200d 0.4%200d 0.4%200d 0.5%300d 1.0%300d FAST undefined undefined undefined 0.4%300d 0.4%300d 0.5%400d 1.0%400d Sampling SLOW 1.2%200d 0.6%200d 0.4%100d 0.4%100d 0.6%200d 1.2%300d undefined MEDIUM undefined undefined 0.6%200d 0.6%200d 0.6%200d 1.2%300d undefined FAST undefined undefined undefined 0.6%300d 0.6%300d 1.2%400d undefined 10 Hz to 20 Hz 20 Hz to 45 Hz 45 Hz to 300 Hz All Ranges 300 Hz to 1 kHz 1 kHz to 3 kHz 3 kHz to 10 kHz 10 kHz to 30 kHz Specified input is 16 mA or higher Specified input is 160 mA or higher Additional error due to crest factor: 1 Frequency (Hz) Accuracy %, ppm=reading error, d=digit error For all gate times Thermal Square-wave input between 10 Hz to 300 kHz, 10 V p-p. coefficient 0.015% 2d 5 ppm All Ranges Range Frequency gate time FAST MEDIUM SLOW 15 6 ms 110 10 ms 1,010 20 ms Measurement time: from gate time to the input signal period 2 3239 specifications (Accuracy at 23C5C (73F9F), 80% rh or less) Resistance () 4-terminal measurement Range Resolution Full scale Current Open terminal voltage Overload protection 200 1 m 199.999 Appox. 1 mA 6V DC max. V, terminal 2000 10 m 1999.99 Appox. 1 mA 6V DC max. 500Vpeak 20 k 100 m 19.9999k Appox. 100A 6V DC max. 200 k 1 199.999k Appox. 10A 6V DC max. SENSE terminal 400Vpeak 2000 k 10 1999.99k Appox. 1 A 6V DC max. Resistance () at Low Power function 4-terminal measurement Range Resolution Full scale 2000 10 m 1999.99 20 k 100 m 19.9999k 200 k 1 199.999k 2000 k 10 1999.99k Current Open terminal voltage Overload protection Appox. 100A 0.45V DC max. V, terminal Appox. 10A 0.45V DC max. 500Vpeak Appox. 1 A 0.45V DC max. SENSE terminal Appox. 100nA 0.45V DC max. 400Vpeak 6 3237 DC voltage (DC V) Accuracy %, ppm=reading error, d=digit error Range 200 mV 2000mV 20 V 200 V 1000 V 3238, 3239 DC voltage (DC V) Accuracy %, ppm=reading error, d=digit error Sampling SLOW 0.026%6d 0.025%2d 0.028%5d 0.028%2d 0.028%2d MEDIUM 0.026%10d 0.025%8d 0.028%10d 0.028%8d 0.028%8d FAST 0.035%300d 0.03%100d 0.035%100d 0.035%100d 0.035%100d Thermal coefficient 20ppm0.6d 15ppm0.2d 20ppm0.5d 20ppm0.2d 20ppm0.2d Sampling SLOW 0.012%6d 0.01 %2d 0.016%5d 0.016%2d 0.016%2d MEDIUM FAST 0.012%10d 0.02%300d 0.01 %8d 0.015%100d 0.016%10d 0.02%100d 0.016%8d 0.02%100d 0.016%8d 0.02%100d Thermal coefficient 12ppm0.6d 10ppm0.2d 16ppm0.5d 16ppm0.2d 16ppm0.2d CMRR (50/60Hz Rl=1k): SLOW 130dB, MEDIUM 90dB, FAST 20dB NMRR (50/60Hz ): SLOW 70dB, MEDIUM 50dB, FAST 0dB 3237 AC voltage (AC V) Accuracy %, ppm=reading error, d=digit error Range Frequency 3238, 3239 AC V Accuracy %, ppm=reading error, d=digit error Sampling Thermal coefficient SLOW MEDIUM FAST SLOW 10 Hz to 20 Hz 1.5%200d undefined undefined 0.15%20d 0.8%200d 20 Hz to 45 Hz 0.5%200d undefined undefined 500ppm20d 0.2%200d 45 Hz to 300 Hz 0.2%100d 0.5%300d undefined 200ppm10d 0.1%100d 300 Hz to 3 kHz 0.2%100d 0.2%200d 0.2%300d 200ppm10d 0.1%100d All 3 kHz to 10 kHz 0.3%200d 0.3%200d 0.3%300d 300ppm20d 0.1%100d Ranges 10 kHz to 30 kHz 1.5%600d 1.5%600d 1.5%700d 0.15%60d 0.3%400d 30 kHz to 50 kHz undefined undefined undefined undefined 0.3%400d 50 kHz to 100kHz undefined undefined undefined undefined 1.5%1000d 100kHz to 300kHz undefined undefined undefined undefined 5.0%5000d The accuracy above is standard for inputs higher than 8% of full scale (higher than 160 V for a range of 750 V). 3237 Resistance () Accuracy %, ppm=reading error, d=digit error Measurement Range Sampling MEDIUM undefined undefined 0.3%200d 0.1%200d 0.1%200d 0.3%400d 0.3%400d 1.5%1000d 5.0%5000d FAST undefined undefined undefined 0.1%300d 0.1%300d 0.3%500d 0.3%500d 1.5%1100d 5.0%5000d Thermal coefficient 800ppm20d 200ppm20d 100ppm10d 100ppm10d 100ppm10d 300ppm40d 300ppm40d 0.15%100d 0.5%500d Additional error due to crest factor: 1 Sampling SLOW 0.05 %8d 0.05 %2d 0.05 %2d 0.05 %2d 0.05 %2d 0.3 %4d 3.0 %10d MEDIUM 0.05 %18d 0.05 %12d 0.05 %12d 0.05 %12d 0.05 %12d 0.3 %20d 3.0 %50d FAST 0.05%300d 0.05%100d 0.05%100d 0.05%200d 0.05%200d 0.3 %200d 3.0 %500d Sampling SLOW 0.03 %8d 0.02 %2d 0.02 %2d 0.02 %2d 0.03 %2d 0.2 %4d 3.0 %10d MEDIUM 0.03 %18d 0.02 %12d 0.02 %12d 0.02 %12d 0.03 %12d 0.2 %20d 3.0 %50d FAST 0.03%300d 0.02%100d 0.02%100d 0.02%200d 0.03%200d 0.2 %200d 3.0 %500d 200 2000 20 k 2terminal 200 k measurement 2000 k 20 M 100 M Thermal coefficient 30ppm0.8d 20ppm0.2d 20ppm0.2d 20ppm0.2d 30ppm0.2d 200ppm0.4d 0.3%1d After zero adjustment. When measuring high resistance, use a shielded cable such as the 9236 CONNECTION CORD (1.7m). 3237 Resistance () Accuracy at Low Power function Measurement Range 3238, 3239 Resistance () Accuracy at Low Power function Thermal coefficient 50ppm0.6d 50ppm0.6d 50ppm0.6d 300ppm0.6d Sampling SLOW 0.05 %6d 0.05 %6d 0.05 %6d 0.3 %6d MEDIUM 0.05 %14d 0.05 %14d 0.05 %14d 0.3 %20d FAST 0.05 %300d 0.05 %300d 0.05 %300d 0.3 %500d Sampling SLOW 0.02 %6d 0.02 %6d 0.02 %6d 0.2 %6d MEDIUM 0.02 %14d 0.02 %14d 0.02 %14d 0.2 %20d FAST 0.02%300d 0.02%300d 0.02%300d 0.2 %300d 2000 20 k terminal 200 k measurement 2000 k 2- Thermal coefficient 20ppm0.6d 20ppm0.6d 20ppm0.6d 200ppm0.6d After zero adjustment. When measuring high resistance, use a shielded cable such as the 9236 CONNECTION CORD (1.7m). 3237 Continuity check Accuracy %, ppm=reading error, d=digit error Range 2000 3238, 3239 Continuity check Accuracy %, ppm=reading error, d=digit error Sampling FAST only 0.05 %300d Thermal coefficient 50ppm0.6d Sampling FAST only 0.02 %300d Thermal coefficient 20ppm0.6d 3237 Diode check Accuracy %, ppm=reading error, d=digit error Range 2000 3238, 3239 Diode check Accuracy %, ppm=reading error, d=digit error Sampling SLOW 0.025% 2d MEDIUM 0.025% 8d FAST 0.03% 100d Thermal coefficient 15ppm0.2d Sampling SLOW 0.01 %2d MEDIUM 0.01 %8d FAST 0.015%100d Thermal coefficient 10ppm0.2d Resistance () Accuracy %, ppm=reading error, d=digit error Measurement Range 4-terminal measurement Resistance () Accuracy at Low Power function Thermal coefficient 30ppm0.8d 20ppm0.2d 20ppm0.2d 20ppm0.2d 30ppm0.2d 4-terminal measurement Sampling SLOW 0.03 %8d 0.02 %2d 0.02 %2d 0.02 %2d 0.03 %2d MEDIUM 0.03 %18d 0.02 %12d 0.02 %12d 0.02 %12d 0.03 %12d FAST 0.03 %300d 0.02 %100d 0.02 %100d 0.02 %200d 0.03 %200d Sampling SLOW No range 0.02 %6d 0.02 %6d 0.02 %6d 0.2 %6d MEDIUM No range 0.02 %14d 0.02 %14d 0.02 %14d 0.2 %20d FAST No range 0.02%300d 0.02%300d 0.02%300d 0.2 %300d 200 2000 terminal 20 k measurement 200 k 2000 k 4- Thermal coefficient No range 20ppm0.6d 20ppm0.6d 20ppm0.6d 200ppm0.6d The accuracy quoted above is for a contact resistance of 100 or less. 7 3237, 3238, 3239 General Specifications AC measurement: True RMS value measurement Crest factor: 3.0 max. Ancillary functions: Comparator, Average (0 to 99 times), Zero Adjust, Trigger (the display changes when the trigger is activated), and the Save/Load functions. (Up to 30 types of setting conditions) Interface: External input/output, RS-232C and GP-IB (option -01 specifications) Display: LED max. 199999 (999999 for frequency) Sampling rate (see page 1): SLOW approx. 1 samples/s MEDIUM approx. 8 to 9 samples/s FAST approx. 300 samples/s (Does not apply at resistances higher than 2M, or LP higher than 200k) (self-calibration takes place for approximately 55 ms at 30-minute intervals for FAST sampling only.) Range selection: Auto and Manual Applicable standards: Safety: EN61010-1+A2, EN61010-2-031 Lo terminal: CAT I (500V), CAT II (300V) Hi terminal: CAT I (1000V), CAT II (600V) EMC: EN61326+A1 Class B, EN61000-3-2+A1+A2, EN61000-3-3 Ambient temperature of use: 0 to 40 C(32F to 104F) 80%RH (no condensation) Storage temperature range: -10 to 50C(-14F to 122F) 70%RH (no condensation) Power supply: Select from AC 100 V/120 V/220 V/240 V, (50/60 Hz) specify when ordering Maximum rated power: 15 VA Dimensions and mass: Approx. 215 W80 H265 D mm, 2.6kg Approx 8.5 W 3.5 H 10.4 D, 91.7 oz. Economical Type Options RS-232C cable RS-232C CABLE 9637 (9pin-9pin, Reverse type/1.8m) RS-232C CABLE 9638 (9pin-25pin, Reverse type/1.8m) GP-IB cable The specifications of the 3237, 3238 and 3239 are -01 specifications GP-IB CABLE 9151-02 (2m) GP-IB CABLE 9151-04 (4m) Printer PRINTER CONNECTOR CABLE AC ADAPTER AC ADAPTER AC ADAPTER RECORDING PAPER 9442 9444 (For 9442 printer) 9443-01 (For 9442 printer, Japan) 9443-02 (For 9442 printer, EU) 9443-03 (For 9442 printer, America) 1196 (For printer, 10 rolls) DIGITAL HiTESTER 3237 DIGITAL HiTESTER 3237-01 (with GP-IB) Advanced Type DIGITAL HiTESTER 3238 DIGITAL HiTESTER 3238-01 (with GP-IB) 4-terminal function & Advanced Type DIGITAL HiTESTER 3239 DIGITAL HiTESTER 3239-01 (with GP-IB) When you purchase a PRINTER 9442, you must also purchase a 9444 CONNECTOR CABLE and a AC ADAPTER 9443 to connect it to the DMM. cord length 65cm TEST LEAD 9170-10 (included) Options Clamp sensors CLAMP ON PROBE 9010-50 (10/20/50/100/200/500A AC ) CLAMP ON PROBE 9018-50 (10/20/50/100/200/500A AC, Broadband type) CLAMP ON PROBE 9132 (20/50/100/200/500/1000A AC ) For Clamp sensors specifications, see page 4. 9010-50 For printer specifications, see page 3. 4-Terminal measurement probe for 3239 CLIP-TYPE LEAD 9287-10 (Approx. 85 cm between connectors, and 8 cm between probes) CLIP-TYPE LEAD 9452 (Approx. 80 cm between connectors, and 20 cm between probes) FOUR-TERMINAL LEAD 9453 (Approx. 80 cm between connectors, and 30 cm between probes) PIN-TYPE LEAD 9461 (Approx. 40 cm between connectors, and 25 cm between probes) 9287-10 9452 9453 9461 HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: info-sh@hioki.cn DISTRIBUTED BY HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: info-bj@hioki.cn Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: info-gz@hioki.cn 3239E4-79M-03P Printed in Japan Guangzhou Office : All information correct as of Sep. 12, 2007. All specifications are subject to change without notice. |
Price & Availability of 3239
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |