![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MPM-15IS Series B Board Mount, 15W dM t Single, Dual & Triple Out AC/DC Power Supplies Key Features: * 15W Output Power * Universal 85-265 VAC Input * EN 60950 Approved * Meets IEC Safety Class II * Industry Standard Pin-Out * Single, Dual & Triple Outputs * Meets EN55022 B * >250 kHour MTBF Chassis Mount Models & DIN Rail Mount Option Available! Electrical Specifications Specifications typical @ +25C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. Max. 85 265 47 440 See Model Selection Guide 115 VAC 15.0 230 VAC 30.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 0.1 230 VAC 0.3 Units VAC Hz A Pk mA Units Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual, Triple Aux Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide 1.0 2.0 VIN = Min to Max 0.5 1.0 IO = Min to Max 0.5 1.0 IO = Min to Max 2.5 5.0 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 4,700 500 Typ. Max. % % % % %VP-P of VO mSec %/C % of VO General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI Units VAC VAC M EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Units C C % MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com EMC Compliance Switching Frequency Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Physical Case Size Case Material Weight 2.91 x 2.13 x 0.76 Inches (74.0 x 54.0 x 19.3 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 4.01 Oz (114g) Conditions Min. Typ. MIL HDBK 217F, 25C, Gnd Benign 280 IEN 60950, IEC 60950 IEN 60950, IEC 60950 IEC 61140 Class II Max. Units kHours Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Model Selection Guide Model Number MPM-15S-05IS MPM-15S-12IS MPM-15S-15IS MPM-15S-24IS MPM-15S-48IS MPM-15D-12IS MPM-15D-15IS MPM-15T-0512IS MPM-15T-0515IS Output 1 (Vout 1) Current (A) Voltage 115 VAC 230 VAC (VDC) Max. Min. 0.290 0.275 0.275 0.275 0.273 0.275 0.275 0.290 0.284 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 5.0 12.0 15.0 24.0 48.0 +12.0 +15.0 5.0 5.0 3.000 1.250 1.000 0.625 0.310 +0.625 +0.500 2.000 1.80 0.300 0.125 0.100 0.063 0.030 +0.063 +0.050 +0.200 +0.200 Input Current (A) Output 2 (Vout 2) Current (A) Voltage (VDC) Max. Min. Output 3 (Vout 3) Current (A) Voltage (VDC) Max. Min. Capacitive Efficiency Load (%, Typ) (F, Max) -12.0 -15.0 +12.0 +15.0 -0.625 -0.500 +0.200 +0.150 -0.063 -0.050 +0.020 +0.015 -12.0 -15.0 -0.200 -0.150 -0.020 -0.015 3,900 2,200 2,200 2,200 1,000 1,500 1,500 Note 5 Note 5 75 79 79 79 79 79 79 74 74 Other output combinations are available Contact the factory for details at: sales@micropowerdirect.com Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a "hiccup mode" circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. For triple output models, the maximum capacitive load for the primary (5 VDC) output is 2,200 F. For the auxilliary outputs it is 1,500 F. 6. The MPM-15IS series includes a built-in 2A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Derating Curve Mechanical Dimensions Pin Connections Pin Single Dual Triple 1 AC-Neutral AC-Neutral AC-Neutral 2 AC-Line AC-Line AC-Line 3 NP NP -Vo 3 4 -Vo -Vo Common 5 NP Common +Vo 2 6 +Vo +Vo -Vo 1 7 NP NP +Vo 1 NP = No Pin Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25) MicroPower Direct www.micropowerdirect.com * 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 * FAX: (781) 344-8481 * E-Mail: sales@micropowerdirect.com |
Price & Availability of MPM-15T-0512IS
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |