Part Number Hot Search : 
ADG792A YMZ280B FB9N65A 50WF10 5KE110A 5KE110A UPC1026 TSS0002
Product Description
Full Text Search
 

To Download HRP-75-24 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 75W Single Output with PFC Function
Features :
Universal AC input / Full range Built-in active PFC function
HRP-75
Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Protections: Over temperature (optional) Cooling by free air convection 1U low profile 38mm Built-in remote ON-OFF control No load power consumption<0.5W All using 105 long life electrolytic capacitors 5 years warranty
series
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) HRP-75-3.3 3.3V 15A 0 ~ 15A 49.5W 3.1 ~ 3.8V 2.5% 1.0% 2.0% 50ms/230VAC HRP-75-5 5V 15A 0 ~ 15A 75W 80mVp-p 4.7 ~ 5.8V 2.5% 1.0% 2.0% HRP-75-7.5 7.5V 10A 0 ~ 10A 75W 100mVp-p 7.1 ~ 9V 2.5% 1.0% 1.5% HRP-75-12 12V 6.3A 0 ~ 6.3A 75.6W 120mVp-p 11 ~ 13.8V 1.5% 0.3% 1.0% HRP-75-15 15V 5A 0 ~ 5A 75W 150mVp-p 14.2 ~ 18V 1.5% 0.3% 0.5% HRP-75-24 24V 3.2A 0 ~ 3.2A 76.8W 150mVp-p 21.6 ~ 28.8V 1.5% 0.2% 0.5% HRP-75-36 36V 2.1A 0 ~ 2.1A 75.6W 200mVp-p 32 ~ 39.6V 1.5% 0.2% 0.5% HRP-75-48 48V 1.6A 0 ~ 1.6A 76.8W 240mVp-p 45 ~ 55.2V 1.5% 0.2% 0.5%
RIPPLE & NOISE (max.) Note.2 80mVp-p
1800ms, 25ms/230VAC
1800ms, 25ms/115VAC at full load
20ms/115VAC at full load 120 ~ 370VDC PF>0.95/115VAC at full load 82.5% 0.7A/230VAC 65A/230VAC 84% 87% 88% 88.5% 89% 89%
VOLTAGE RANGE Note.5 85 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE PF>0.9/230VAC 77% 1.2A/115VAC 35A/115VAC <1mA / 240VAC
105 ~ 135% rated output power Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
85 5 for 3.3V~15V; 80 5 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional) OVER TEMPERATURE (OPTIONAL) Protection type : Shut down o/p voltage , recovers automatically after temperature goes down RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off REMOTE CONTROL -20 ~ +70 (Refer to output load derating curve) WORKING TEMP.
20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS SAFETY & EMC
(Note 4)
WITHSTAND VOLTAGE ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC / 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 , EN61000-6-2 , heavy industry level, criteria A 394.8K hrs min. MIL-HDBK-217F (25 ) 129*98*38mm (L*W*H) 0.47Kg; 30pcs/ 15Kg/ 0.97CUFT
OTHERS
DIMENSION PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-75-SPEC 2009-10-09
75W Single Output with PFC Function
Mechanical Specification
122.5
HRP-75
Case No.903D
series
Unit:mm
1
9.5
2 3
8.2
33
85.5 9.5 3.5 18
5
SVR1
12
CN100
3 .5
4.5 73.5 129
Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 Assignment DC OUTPUT -V DC OUTPUT +V
9 6.5
120
Pin No. 1 2
Assignment RCRC+
Mating Housing JST XHP or equivalent
Terminal JST SXH-001T or equivalent
32
3L
=5
77
Block Diagram
I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. FG PFC CONTROL PWM CONTROL POWER SWITCHING O.L.P. RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. REMOTE CONTROL RC+ RC+V -V
Derating Curve
Output Derating VS Input Voltage
Ta = 25
100
100 90
80
80 70
60
LOAD (%)
40 30 20
LOAD(%)
60 50 40
-20
0
10
20
30
40
50
60
70
(HORIZONTAL)
85
100
125
135
155
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:HRP-75-SPEC 2009-10-09
28.5
3-M
38
Remote ON/OFF (CN100) : JST B-XH or equivalent
12 max.
18.5
98
4
2-
M
3L
=5
31
3.5
7
3.5


▲Up To Search▲   

 
Price & Availability of HRP-75-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X