Si l O Single Output, 150W 0 Compact, Enclosed AC/DC Power Supplies
Electrical Specifications
Key Features:
* 150W Output Power * Selectable 88-264 AC Input * EN 60950 Compliant * Eight Single Output Models * Meets EN55022 * >285 kHour MTBF * Compact Metal Enclosure
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Input Current Inrush Current Safety Ground Leakage Current Conditions Min. Typ. 88 115 176 220 248 47 See Model Selection Guide Cold Start, 115 VAC 17.0 Cold Start, 230 VAC 35.0 115 VAC 230 VAC Switch Selectable Max. 132 264 370 63 Units VAC VDC Hz A Pk 1.5 3.5 Max. mA Units
Output
Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 20 230 VAC 28 230 VAC 100 230 VAC 50 0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 110 Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Typ.
RoHS Compliant
mSec mSec mSec %/C 135 160 Max. Units VAC
General
Parameter Isolation Voltage Isolation resistance EMI/RFI EMC Compliance Switching Frequency
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
100 M EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 25 kHz Units C C %
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -10 +25 +60 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient
Physical
Case Size Case Material Weight 7.83 x 4.33 x 1.97 Inches (199.0 x 110.0 x 50.0 mm) Vented Metal Enclosure 28.3 Oz (0.8 kg) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25C, Gnd Benign 285 kHours IEN 60950, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Reliability Specifications
Parameter MTBF Safety Standards Vibration
Model Selection Guide
Model Number MPE-150S-05 MPE-150S-09 MPE-150S-12 MPE-150S-13.5 MPE-150S-15 MPE-150S-24 MPE-150S-27 MPE-150S-48 Input Current (A) 115 VAC 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 230 VAC 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 Output Voltage (VDC) Rated 5.0 9.0 12.0 13.5 15.0 24.0 27.0 48.0 Adjust 4.5 - 5.5 8.0 - 10.4 10.6 - 13.2 12.0 - 15.0 13.5 - 16.5 21.0 - 28.0 24.0 - 30.0 43.0 - 53.0 Current (A) Rated 30.0 16.7 12.5 11.2 10.0 6.5 5.6 3.2 Range 0 to 30.0 0 to 16.7 0 to 12.5 0 to 11.2 0 to 10.0 0 to 6.5 0 to 5.6 0 to 3.2 Output Tolerance (%) 2.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Ripple & Noise
(mV p-p)
Efficiency
(%, Typ)
150 180 180 180 180 240 240 240
78 80 82 83 84 85 86 87
Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 F and a 47 F capacitor are connected in parallel as close to the power supply terminals as possible. 3. The overvoltage protection circuit shuts down the output. The unit must be repowered to recover once the fault condition is removed. 4. The overload protection circuit shuts down the output. The unit must be repowered to recover once the fault condition is removed. 5. Efficiency is measured with a 115 VAC input. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPE-150S series, a 7.5A/250 VAC slow blow should be used.
Mechanical Dimensions
Pin Connections
Pin 1 2 3 4 5 6 7 Function AC-Line AC-Neutral AC-Ground -Vout -Vout +Vout +Vout Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
Derating Curve Static Characteristics (24 Vout)
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of MPE-150S-05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X