![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
S/INT/XKR24440/A/28/07/1999 page 1 / 2 F/GB Relais Statique/Montage sur rail DIN Solid State Relay for DIN rail fixation * Gamme pret a l'emploi: Relais montable sur rail DIN . * Inverseur de sens de rotation pour moteurs (<1kW). * Visualisation de commande par LED. * Sortie AC syncrhone. * Ecreteur de surtension integre. * Haute immunite aux perturbations exterieures. * New generation of SSR for DIN rail fixation. * Reverser to motors below 1kW. * Control visualization by LED. * Zero-cross AC Output. * Integrated clamping voltage. * High immunity level. L1 24-460VAC 2,5A AC3 L1L2 L3 XKR24440 15-40 VDC control 4A/ 400VAC output L2 L3 Aplication typique/Typical application F+ Rc L1 L2 L3 celduc France SKA 20460 output 400Vac 4A 1 76,4 0,4 2 XKR24440 Motor Reverser R+ input12-35VDC celduc F+ C-R+ T1 T2 T3 29 0,4 53 0,4 58,2 0,2 C- T1 T2 T3 Caracteristiques de commande (a 20C) / Control characteristics (at 20C) DC Parameter Symbol Min Nom Tension de commande / Control voltage Uc 15 Courant de commande / Control current (@ Uc nom ) Ic 4,4 Tension de relachement/Release voltage Uc off 8 Resistance interne / Input internal resistor fig.1 Rc 2000 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie / Input-output isolation Uiso 4000 Capacite entree-sortie / Input-output capacity Ciso fig. 1 :Caracteristique d'entree / Control characteristic 18 Max 40 17 Unit V mA V Vrms pF 16 14 12 ic(mA) 10 8 6 4 2 0 0 5 10 15 20 Uc(V) 25 30 35 40 8 Caracteristiques thermiques / thermal characteristics Parameter Temperature de stockage /Storage temperature Plage de temperature de fonctionnement /Operating temperature range Caracteristiques generales / General characteristics Poids/Weight Conditions Symbol Tc max Typ. -40 +150 -40 +80 30 C C g Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. r celduc e l a i s LOAD input 6-30Vdc 4 - 3+ France S/INT/XKR24440/A/28/07/1999 page 2 / 2 F/GB Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC1/ AC1 nominal current Courant nominal AC3/ AC3 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Corant de maintien / Holding current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite conduite/Conducted immunity level Symbol Typ. Unit Ul 400 V rms Ulmin-max 24-460 V rms Up 1200 V Usync 12 V Il nom Ua 5 V Il AC1 4 A rms Il AC3 2,5 A rms tp=10ms (Fig. 3) Itsm 120 A @ Il nom Vd 1,6 V @Ul, 50Hz Ilk 0,3 mA Ilmin 5 mA IH 50 mA Uc nom DC ,f=50Hz ton max 10 ms Uc nom DC ,f=50Hz toff max 10 ms f 10-440Hz Hz dv/dt 500 V/s di/dt 20 A/s I2t 50 A2s IEC 1000-4-4 (bursts) 4kV criterion A Conditions Fig. 3 : Courant de surcharge non repetitif / Non repetitive surge current Surge current Itsm (Apeak) = f(t) 150 No repetitive Itsm (Apeak)=f(t) without voltage reapplied Itsm (Apeak) 100 for models with itsm =120A 50 Repetitive Itsm (Apeak)=f(t) with voltage reapplied for initial Tj =70C 0,01 0,1 t(s) 1 10 0 Precautions : * Prevoir un verrouillage interdisant la commande simultanee des 2 sens de rotation, et egalement une temporisation sur une inversion de commande. * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. Cautions : *Control lock must be made to avoid the control of the two inputs at the same time, a temporisation must be add at each inverting. * Semiconductor relays don't provide any galvanic insulation between the load and the mains. celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of XKR24440
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |