![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice 400 WATT POWER FACTOR CORRECTED SUPPLIES DESCRIPTION The PFC400 series of AC/DC switching power supplies are capable of delivering 400 watts of continuous power and incorporate active power factor correction. Three outputs in each unit are equipped with current sharing and oring diode for redundant applications. Other features include remote sense, Power Fail Detect signal and isolated outputs. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking. The series is designed for use in medium-power data networking, telecom, industrial, test and office equipment. PFC400 SERIES (LVD) F E ATU R E S E E E E E E E E P o w e r F a c t o r 0.98 typical 9 0 VA C t o 2 6 4 VA C u n i v e r s a l i n p u t Current sharing, oring diodes and remote sense In compliance with EN 61000-3-2/-3 and EN 55024 ( E N 6 1 0 0 0 - 4 - 2 / - 3 / - 4 / - 5 / - 6 / - 8 / - 11 ) Tightly regulated DC outputs Overvoltage and thermal protection Short-circuit protection Power Fail Detect (PFD) signal S a f e t y St a n d a r d A p p ro v a ls G TUV EN60950-1 Certificate No. R3-50006876 E N V I R O N M E N TA L S P E C I F I C ATI O N S O p e r a t i n g t e m p e r a t u r e G St o r a g e t e m p e r a t u r e G R e l a t i v e h u m i d i t y G D e r a t i n g G C o o l i n g G 0 J t o + 7 0 J - 4 0 J t o + 8 5 J 5 M t o 9 5 M n o n - c o n d e n s i n g D e r a t e f r o m 1 0 0 M a t + 5 0 J l i n e a r l y t o 5 0 M a t + 7 0 J 4 5 . 2 C F M f o r c e d a i r, provided by user I N P U T S P E C I F I C ATI O N S I n p u t v o l t a g e G Input frequency: I n p u t c u r r e n t G L e a k a g e c u r r e n t G 9 0 t o 2 6 4 VA C 47 to 63 Hz 7 . 1 A ] r m s ^ f o r 11 5 VA C 3 . 2 A ] r m s ^ f o r 2 3 0 VA C 0 . 4 6 m A m a x . @ 11 5 VA C , 6 0 H z 0 . 8 m A m a x . @ 2 3 0 VA C , 5 0 H z OUTPUT SPECIFICATIONS Output voltage/currentG Total output powerG Ripple and noiseG Overvoltage protectionG See rating chart 400 watts maximum 2M peak to peak maximum Provided on output #1 only; set at 112-132M of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04M /J maximum Maximum excursion of 4M or better on all models; recovering to 1M of final value within 500us after a 25M step load change TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1 ms prior to +5.1V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after +5.1V is within regulation. GENERAL SPECIFICATIONS Switching frequencyG 94KHz 5KHz Power factorG EfficiencyG Hold-up timeG Line regulationG Inrush currentG 0.98 typical 70% typical 12 msec min. at 115VAC 0.5M max. at full load Overcurrent protectionG Temperature coefficientG Transient responseG PFD signalG 43A @ 115VAC, or 86A @ 230VAC, at 25 J cold start Withstand voltageG 3000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBFG 250,000 hours minimum at full load at 25J ambient, calculated per MIL-HDBK-217F EMC performance (EN55024) EN55022: Class B conducted, Class A radiated FCC: Class B conducted, Class A radiated VCCI: Class B conducted, Class A radiated EN61000-3-2: Harmonic distortion, Class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, 8KV air and 4KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, 1KV EN61000-4-5: Surge, 1KV diff., 2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 1A/m EN61000-4-11: Voltage dips, 30% reduction for 500ms and > 95% reduction for 10ms 1-33 UNIVERSAL INPUT OUTPUT VOLTAGE/CURRENT RATING CHART (1) Model (1) PFC400-50B PFC400-51B PFC400-55B PFC400-56B Notes: Output #1 (2)(3) Output #2 (2)(4) Vnom. Imax. Tol. Vnom. Imax. Tol. +5.1V 40A 2% 3.3V 20A 2% +5.1V 40A 2% 3.3V 20A 2% +5.1V 40A 2% 3.3V 20A 2% +5.1V 40A 2% 3.3V 20A 2% Output #3 (2)(5) Vnom. Imax. Tol. 12V 9A 3% 15V 8A 3% 12V 9A 3% 15V 8A 3% PFC400 SERIES Output #4 Vnom. Imax. 12V 6A 15V 5A 12V 6A 15V 5A Tol. 4% 4% 4% 4% Output #5 Vnom. Imax. 5V 6A 24V 4A 24V 4A 5V 6A Tol. 4% 4% 4% 4% Maximum Output Power(6) 400W 400W 400W 400W (1) Each output is isolated from the others and has individual return. (2) Output #1, #2, and #3 are built with one-wire current sharing and oring diode for redundant connections. (3) Output #1 requires a minimum load of 5A to support other outputs at their maximum rated loads. (4) Output #2 requires a minimum load of 1A to be in regulation. (5) The peak current of output #3 is limited to 12A on 12V, 9.6A on 15V. (6) Forced air cooling of 45.2 CFM minimum is required. Suggested airflow is from the input section to the output section. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. P1 input connector is Beau Inc. P/N 72-5-03C. Screws are #6-32 on 0.375 inch (9.53mm) centers. 4. P4 output connector is Dinkle P/N 166-06P. 5. P8 is for DC fan rated 12V/0.25A 6. P8 & P9 Connector mates with Molex housing. 22-01-1023 and Molex 40445 series crimp terminal. 7. Main output studs P2/P3 are with M5*0.8 screws. 8. Weight: 1.70Kgs (3.74 Lbs.) approx. PIN CHART CONN PIN MODEL P1 P2 1 2 3 P3 1 2 3 P4 4 5 6 1 P5 2 1 FAN (+12V) P8 2 1 P9 2 PFD PFC400-50B PFC400-51B LIVE PFC400-55B PFC400-56B NEUTRAL GROUND OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT #1 #1 RET. #5 #5 RET. #4 #4 RET. #3 #3 RET. #2 #2 ret. OUTPUT#1 OUTPUT ret. #1 ret. CB4 SUB-BOARD (for output #1) P4-1 P4-2 P4-3 +SENSE -SENSE CURRENT SHARE P3-1 P3-2 P3-3 CB6 SUB-BOARD (for output #3) +SENSE -SENSE CURRENT SHARE CB7 SUB-BOARD (for output #2) P3-1 P3-2 P3-3 +SENSE -SENSE CURRENT SHARE 1-34 |
Price & Availability of PFC400
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |