 HR-CR3A HR
5A to 16A low-profile power relay
RoHS
P.C. BOARD POWER RELAY
Features
5mm lower in height than HR-CR3 series Wide contact arrangements 1 Form A to 2 Form C 16A contact capacity Sealed construction standard
Approvals
UL CUL TUV
Applications
Home appliance, Industrial control
1 Pole type Dimensions (mm)
To convert into inches, multiply by 0.03937 1 form A standard type K type 1 form C standard type K type
PC Board Layout
Copper-side view
Schematic
Copper-side view
Selection Guide & Technical Data
R-59
www.DataSheet.in
HR-CR3A HR
RoHS
2 Pole type Dimensions (mm)
To convert into inches, multiply by 0.03937 2 Form A 2 Form C
PC Board Layout
Copper-side view
Schematic
Copper-side view
Socket
KPX14
KPX24
R-60
www.DataSheet.in
HanKuk Relay
HR-CR3A HR
Contact data
Arrangement Contact material Initial contact resistance Type 2 Pole type 2 Form A, C Rated load, resistive 5A 30VDC 5A 250VAC TV-5 Maximum carry current Maximum switching capacity Maximum switching voltage Minimum switching rating1)
1)
RoHS
1 Form A (SPST) to 2 Form C (DPDT)
P.C. BOARD POWER RELAY
Ag Alloy 100m max. 1 Pole typ Standard 1 Form A, C 10A 30VDC 10A 250VAC TV-5 10A 300W 2,500VA 16A 300W 2,500VA K type 1 Form C 10A 30VDC 10A 250VAC 1 Form A 16A 30VDC 16A 250VAC 16A 480W 3,840VA
TV-8
5A with DC voltage: with AC voltage: 150W 1,250VA 250VAC 100mA 5VDC
Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.
Coil data
Nominal voltage Nominal power consumption2) Operate voltage
2), 3), 4) 3) 4)
5VDC to 48VDC 530mW, 720mW 80% of nominal voltage 10% of nominal voltage
Release voltage
The values depend on coil voltage, see Part selection chart
General data
Operate time Release time Initial insulation resistance Dielectric strength Surge strength Expected life Vibration resistance Shock resistance Ambient temperature Humidity Weight Note: The above figures are initial values Between open contacts: Between contacts and coil: Between contacts and coil: Mechanical: Electrical: Functional: Destructive: Functional: Destructive: 15ms max. at nominal voltage 8ms max. at nominal voltage 1,000 M min. (500VDC) 1,000VACrms for 1 minute 5,000VACrms for 1 minute 10,000V More than 10,000,000 operations More than 100,000 operations at rated load 10 ~ 55Hz dual amplitude: 1.5mm 10 ~ 55Hz dual amplitude: 1.5mm 10G min. 100G min. - 40C to + 70C (with no icing) 45% to 85% RH 13g approx.
Selection Guide & Technical Data
R-61
www.DataSheet.in
HR-CR3A HR
Part number description
RoHS
HR-CR3A
No. of poles
1: Single pole 2: Double poles
Contact arrangement
1: Form C contact 3: Form A contact
Coil voltage
DC05: 5VDC DC06: 6VDC DC09: 9VDC DC12: 12VDC DC18: 18VDC DC24: 24VDC DC48: 48VDC 5A 30VDC 5A 250VAC (2 Form A, C) 10A 30VDC 10A 30VDC (1 Form A, C)
Contact rating
None: Standard
K: 16A 30VDC 16A 250VAC (1 Form A,C type only)
Enclosure
None: Sealed type, black C: Flux free type, clear
Coil sensitivity
None: Standard (720mW) H: High sensitive (530mW)
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part selection
Fill in the codes to the part number by selecting them from the part number description
Part number Nominal voltage (VDC) Coil resistance ( 10%) Nominal current (mA) Must operate Must release voltage voltage (VDC) (VDC) Max voltage (VDC) Nominal power (mW)
Sensitive coil HR-CR3A HR-CR3A HR-CR3A HR-CR3A HR-CR3A HR-CR3A HR-CR3A Sensitive coil HR-CR3A HR-CR3A HR-CR3A HR-CR3A HR-CR3A HR-CR3A HR-CR3A
1 Form C, 1 Form A, 2 Form C, 2 Form A DC05 DC06 DC09 DC12 DC18 DC24 DC48 DC05 DC06 DC09 DC12 DC18 DC24 DC48 H H H H H H H 5 6 9 12 18 24 48 5 6 9 12 18 24 48 35 50 112 200 450 800 3,200 47 68 153 273 620 1,085 4,350 144 120 80 60 40 30 15 106 88 59 44 29 22.1 11.0 4.0 4.8 7.2 9.6 14.4 19.2 38.4 4.0 4.8 7.2 9.6 14.4 19.2 38.4 0.5 0.6 0.9 1.2 1.8 2.4 4.8 0.5 0.6 0.9 1.2 1.8 2.4 4.8 6.5 7.8 11.7 15.6 23.4 31.2 62.4 6.5 7.8 11.7 15.6 23.4 31.2 62.4 530 720
1 Form C, 1 Form A, 2 Form C, 2 Form A
Note: All values in the chart are measured at 23C
R-62
www.DataSheet.in
HanKuk Relay


▲Up To Search▲   

 
Price & Availability of HR-CR3A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X