 225 Watts
CE-225 Series
Features
* Universal 85-264 VAC Input * Harmonic Current Per EN 61000-3-2 * Compact 4.75" X 8" X 2.0" Size * Standard U Shaped Chassis * Optional Perforated Cover * Optional Remote On/Off * Optional Power Fail Signal * Conducted Emissions Per EN 55022,11 * EMC Compliant to EN 61000-4-2, 3, 4, 5, 6 & 11 and EN 60601-1-2 * 2 Year Warranty * EN 60950 ITE Certification * EN 60601-1 Medical Cert.
All specifications are maximum at 25C unless otherwise stated and are subject to change without notice.
Output Specifications
Total Output Power Output Voltage Centering 150W , Convection Cooled 225W, 300 LFM Forced Air Output 1: 0.25% Output 2: 0.25% (X0XX) (All outputs at Output 2: 5.0% (X1XX) 50% rated load) Output 3: 2.0% Output 4: 2.0% Outputs 1-4: 0.5% Output 1: 0.5% (10-100% Load Change) Output 2: 0.5% (X0XX Models,0-100%) Output 2: 5.0% (X1XX Models,10-100%) Output 3-4: 2.0% (0-100% Load Change) Output 2: 0.2% (X0XX) (Output 1 load Output 2: 5.0% (X1XX) varied 50-100%) Outputs 3-4: 2.0% Outputs 1-2: 95-105% (X0XX Models) Output 1: 95-105% (X1XX Models) Output 1: 85-105% (1001 & 4001) Output 2: 85-105% (4002 & 4003) 1% Outputs 1-4: 0.5% Outputs 1-4: 1% Outputs 1-4: 1% None Outputs 1-4 5% 500 S 50% To 100% Output 1: 110% to 150%, Shuts down all outputs Cycle input to restart 250 Watts Min.,Output 1 Outputs cycle on/off, auto recovery 110% Min., Outputs 2,3 & 4 20 mS Min., 225W Output, 120V Input 3 Seconds
Source Regulation Load Regulation
Cross Regulation
Output Voltage Adjust Span Resolution Output Noise Source Freq. Switching Freq. Total (20MHz) Turn On Overshoot Transient Response Voltage Deviation Recovery Time Load Change Output Overvoltage Protection (Optional) Output Overpower Protection Output Overcurrent Protection Hold Up Time Protection Class: Overvoltage Category: Pollution Degree: UL1950 Third Edition UL2601-1 Second Edition CB Report Per IEC 950 (1991) Second Edition A1, A2, A3, A4 All EN 60950 Deviations CB Report Per IEC 601-1-1988 First Edition, A1, A2 CAN/CSA-C22.2 No. 950-M95 CAN/CSA-C22.2 No. 601-M90 EN 60950/A4 (1997) EN 60601-1/A2 (1995) Low Voltage Directive I I| 2 Start Up Time
Safety Specifications
General
Underwriters Laboratories File E137708
Input Specifications
Source Voltage Frequency Range Source Current True RMS Peak Inrush Peak Repetitive Harmonic Distortion Efficiency Power Factor 85 - 264 Volts AC 47-63 Hz 4.25A at 85V Input 30A 6.0A at 85V Input 0.05 .68 -.80 (varies by model) 0.92 (225 Watts, 230V)
UL Recognition Mark For Canada File E137708 TUV License B 98 07 30824 004
Environmental Specifications
Ambient Operating Temperature Range Ambient Storage Temperature Range Temperature Coefficient Vibration Shock 0 C to +70 C Derating: See Power Rating Chart -40 C To +85 C Outputs 1-4: 0.02%/C MIL-STD-810E, Method 514.4 Category 1 Transit Drop per MIL-STD-810E Method 516.4 Procedure IV
Model Listing
MODEL CE-225-4001 CE-225-4002 CE-225-4003 CE-225-4004 CE-225-4005 CE-225-4006 CE-225-4007 CE-225-4101 CE-225-4102 CE-225-3001 CE-225-3002 CE-225-2001 CE-225-2002 CE-225-2003 CE-225-2004 CE-225-2101 CE-225-1001 CE-225-1002 CE-225-1003 CE-225-1004 CE-225-1005 CE-225-1006 CE-225-1007 OUTPUT 1 +3.3/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +5V/25A(1) +12V/10A(1) +15V/10A(1) +5V/25A(1) +5.2V/30A +5V/25A(1) 3.3V/45A(6) 5V/45A(6) 12V/18.8A(1) 15V/15A(1) 24V/9.4A(1) 28V/8A(1) 48V/4.7A(1) OUTPUT 2 +5V/8A(1) +3.3V/8A(1) +3.3V/8A(1) -5.2V/8A(1) -5.2V/8A(1) +12V/8A(1) +12V/8A(1) +24V/8A(1) +24V/8A(1) +12V/8A(1) +15V/8A(1) -12V/8A(1) -15V/8A(1) +12V/8A(1) -9V/6A +24V/8A(1) OUTPUT 3 +12V/2A(1) +12V/2A +15V/2A +12V/2A +15V/2A +12V/2A +15V/2A +12V/2A +15V/2A OUTPUT 4 -12V/2A(1) -12V/2A -15V/2A -12V/2A -15V/2A -12V/2A -15V/2A -12V/2A -15V/2A -12V/2A -15V/2A
General Specifications
Dielectric Strength 5656 VDC, Primary to Secondary, 1 Sec. 2121 VDC, Primary to Ground, 1 Sec. 500 VDC, Secondary to Ground, 1 Sec. <300 A Earth Leakage Current <100 A Patient Leakage Current Contact closure shuts off all outputs Logic low with input power failure 10mS minimum prior to output one dropping 1% 250mV compensation of output cable losses 100,000 Hours min., MIL-HDBK-217F, 25 C, GB 3.00 Lbs.
Leakage Current Remote On/Off (Optional) Power Fail Signal (Optional) Remote Sense Mean-Time Between Failures Weight
Electromagnetic compatibility specifications located on page 21.
Refer to "Applications Information" on page 21. Ph: (570) 824-4666 * Fx: (570) 824-4843
20
CE-225 Series Mechanical Specifications
Electromagnetic Compatibility Specifications
Electrostatic Discharge Radiated Electromagnetic Field EFT/Bursts Surges Conducted Immunity Voltage Dips Voltage Interruptions Radiated Emissions Conducted Emissions Harmonic Current Emissions EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 EN 61000-4-11 EN 55011 EN 55022 EN 55011 EN 55022 EN 61000-3-2 6kV Contact Discharge 3V/M, 26-1000MHz 2kV 1 kV Differential Mode 2 kV Common Mode 3V,150KHz-80MHz 30% Reduction, 10mS 60% Reduction, 100mS 95% Reduction 5000mS Class B Class B Class B Class B
Specifications are typical across product line and may vary by model.
Applications Information
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Derated 20% when convection cooled Consult factory for alternate output configurations. Consult factory for positive, negative, or floating outputs. Specify optional overvoltage protection, remote on/off, power fail signal or cover when ordering. Each output can deliver its rated current but total output power must not exceed 150 or 225 watts as determined by the cooling method. Rated 30 amps maximum when convection cooled only. This product is intended for use as a professionally installed component within the medical and information technology equipment. Free air convection cooling, 150 watts maximum output power. Forced air cooling rating of 225 watts requires an air speed of 300 linear feet per minute flowing past a point one inch above the main isolation transformer. A minimum load of 10% is required on output one to ensure proper regulation of remaining outputs. Remote sense terminals (Figure 1) may be used to compensate for cable losses up to 250mV (single output models only). The use of a twisted pair is recommended as well as a decoupling capacitor CD (0.1-10F) and a capacitor CL of 100F/Amp connected across the load side. Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing AC dielectric strength test. The input circuit includes only one fuse in the "line" conductor. In consideration to paragraph 57.6 of UL 2601-1, when used in medical applications, a fuse should be added to the "neutral" conductor in the end product.
12.
13.
AC Input Connector P1:
* .156 inch friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
14.
DC Output Connector P2: (Single Output)
* 6-32 screw down terminal mates with # 6 ring tongue terminal.
DC Output Connector P2: (Multi Output)
* .156 inch friction lock header mates with Molex 09-50-3181 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
Maximum Output Power vs. Ambient Temperature
220 200
Ground Connector
:
Output Power, (Watts)
180 160 140 120 100 80 60 40 20 0
FORCED AIR COOLING
* Ground mates with .187 inch quick disconnect terminal.
Option/Sense Connector P3: (Single Output)
* .100 inch friction lock header mates with Molex 22-01-2087 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
CONVECTION COOLING
Option/Sense Connector P3/P4: (Multi Output)
* .100 inch friction lock header mates with Molex 22-01-2047 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
0
10
20
30
40
50
60
70
Ambient Temperature (C)
Optional cover increases height dimension from 2.00 to 2.15 inches.
Figure 1 - Output sense connections
Ph: (570) 824-4666 * Fx: (570) 824-4843
21


▲Up To Search▲   

 
Price & Availability of CE-225-1001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X