EMC-Power Line Filters for 1-Phase Systems FMLB Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR (Umax): Attenuation: Leakage current: Test voltages: Climatic category: 50% saturation typ.: Inrush current: MTBF @ 40 C / UR (Umax): * without resistor 6 - 20 A @ 40 C 125/250 VAC 50/60 Hz Standard for Standard and Medical applications L/N E 2.7 kVDC, 2 sec L N 1.7 kVDC, 2 sec * 25/100/21 acc. to IEC 60068-1 2 to 3 x IN @ 20 C 1.5 x IN 1 min. per hour > 200'000 h acc. To MIL-HB-217 F Standard and Medical Versions The SCHURTER filter family has been specially developed for universal industrial applications such as: * Control systems * Power supplies * Stepper motor drives * Power converters International approvals center (i.e. UL) today demand high filter performance with regard to attenuation and loading characteristics. During the design, special considerations were made for applications that require high attenuation at the specified maximum load or where asymmetrical loading of the filter occur independently from line impedance at the installation site. The implemented filter range wholly conforms to the requirements of the international standards EN 133200, UL 1283 and IEC 60950 and is ideally suited for applications with EN 55011, EN 55014and EN 55022 requirements. Order Numbers and Technical Data Type FMLB Standard 5500.2035 5500.2036 5500.2037 5500.2038 Type FMLB Medical M5 5500.2082 5500.2083 5500.2084 5500.2085 IN (1) @ a 40 C [A] 6 10 16 20 IN (1) @ a 40 C [A] 6 10 16 20 UR (Umax) [VAC] 250 250 250 250 UR (Umax) [VAC] 250 250 250 250 LN (2) -30% / +50% [mH] 2 2 2 2 x 14.0 x 5.0 x 2.0 x 1.5 * Version with quick connect terminals (flat pins, 6.3 x 0.8 mm) is produced as standard series. * Key features of the high-current filter series: - simple, space-saving installation - excellent price/performance ratio - good common mode attenuation characteristics (from 10 kHz to 300 MHz) * To maximize the filter performance, the following EMC rules should be considered: - physical separation of filter input and output lines - physical separation of the interference source itself Optional versions: * Version with cable connections in place of the quick connect terminals * Medical version M80* with leakage current < 80A *Contact Schurter for minimum order quantity Leakage current (3) @ 250 V / 50 Hz [mA] < < < < 0.35 0.35 0.35 0.35 Cx(X2) [F] 0.1 0.1 0.1 0.1 Cx(X2) [F] 0.1 0.1 0.1 0.1 Cy(Y2) [nF] 3.3 3.3 3.3 3.3 Cy(Y2) [nF] - R [M] R [M] 1 1 1 1 Case 49 49 49 49 Case LN (2) -30% / +50% [mH] 2 2 2 2 x 14.0 x 5.0 x 2.0 x 1.5 Leakage current (3) @ 250 V / 50 Hz [A] < < < < 5 5 5 5 49 49 49 49 (1) Current derating over 40C : I = IN x (100-a)/60 (2) Nominal inductance measured according to EN 138100, see introduction of this catalog, paragraph 3.4 (3) Measured according to IEC 60950 5.2.3 Annex D, see introduction of this catalog, paragraph 3.5 Versions with connecting cables are available on request: min. order 100 pieces. Case 49 Circuit diagram Insertion loss Standard Insertion loss Medical M5 24 www.schurterinc.com |
Price & Availability of 5500204
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |