W6/W9 series Magnetic Hydraulic Circuit Breakers Features * Designed for the international market. UL Recognized, CSA Certified, and VDE approved. * Ratings to 50 amps. * Heavy duty #10-32 stud connections. (W9) * Optional 10 amp auxiliary switch. * Optional snap-in mounting. (W6) www..com * Several delay curve options. * Trip-free operation. Typical Resistance and Impedance Current (Amps) 0.2 1.0 2.0 5.0 10.0 20.0 30.0 40.0 50.0 DC Resistance (Ohms) 90 1.2 0.28 0.04 0.013 0.004 0.0027 0.002 0.0015 50/60 Hz. Impedance (Ohms) 90 1.2 0.28 0.04 0.013 0.005 0.004 0.002 0.0015 400 Hz. Impedance (Ohms) 180 2.0 0.50 0.05 0.025 0.0065 0.004 0.003 0.0025 Tolerance: 0.1 - 4.99 15%; 5 - 9.99 20%; 10 - 15 25%; 16 - 30 50%. Agency Approvals Recognized as Supplementary Protector under UL 1077 File . E69543. CSA: Certified as a Supplementary Protector. File LR15734. VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment) License No. 73782. UL: Mechanical/Environmental Data Operating Temperature: -40C to +85C. Humidity: Meets requirements of Mil-STD-202 method 103. Shock: Tested per Mil-STD-202, method 213, test condition C (100g @ 6 ms). Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm) total excursion in 2 planes. Fungus And Moisture Resistance: Special moisture resistant finish applied to all ferrous parts. Plastic parts are made of inherently fungus resistant material. Marking: W6 units have ON and OFF molded on the rocker of rocker actuated units (rocker actuated VDE units have international "1" and "0"). W9 units have ON and OFF molded into the area at the base of the toggle. International "1" and "0" symbols are marked on the toggle for both W6 and W9. Mounting: Panel mounted units are mounted with two #6-32 screws from the front of the panel. Metric models for use with M3 x 0.5 screws are available. Units with snap-in mounting option snap through the front of the panel. To maintain published performance specifications, units should not be mounted more than 90 from their normal upright position. Weight: Approximately 2.5 ounces per pole. Electrical Data Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details. Calibration: Breakers will hold 100% of rated current. Breakers may trip between 101% and 124% of rated load (149% for 400 Hz. units and 134% for AC/DC units). Breakers must trip at 125% of rated load and above (150% for 400 Hz. units and 135% for AC/DC units). Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V. Insulation Resistance: 100 Megohms at 500VDC. Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load. Units tested at six cycles per minute, 1 second on and 9 seconds off at 25C ambient. Approvals and Ratings Table 1 W6 Series Maximum Voltage 65 277 277 277/480 250 250 250 UL/CSA (All Circuit Functions) Frequency (Hz) DC 50/60 50/60 50/60 400 400 400 Current Phase 1 1 3O-Wye 1 1 3O-Wye Interrupting Rating (Amps) 0.2 - 50 0.2 - 20 21 - 50 0.2 - 20 0.2 - 20 21 - 50 0.2 - 20 Capacity (Amps) 2,000 5,000 2,500 5,000 2,500 1,250 2,500 W6 Series Maximum Voltage 65 250 250 415/240 VDE (Circuit Function X) Frequency (Hz) DC 50/60 50/60 50/60 Current Phase 1 1 3O Interrupting Rating (Amps) 0.2-50 0.2-30 31-50 0.2-30 Capacity (Amps) 2,000 5,000 2,000 5,000 W9 Series Maximum Voltage 65 277 277/480 250 250 UL/CSA (All Circuit Functions) Frequency (Hz) DC 50/60 50/60 400 400 Current Phase 1 3O-Wye 1 3O-Wye Interrupting Rating (Amps) 0.2 - 50 0.2 - 50 0.2 - 20 0.2 - 50 0.2 - 50 Capacity (Amps) 2,000 5,000 5,000 2,500 2,500 W9 Series Maximum Voltage 65 250 250 415/240 VDE (Circuit Function X) Frequency (Hz) DC 50/60 50/60 50/60 Current Phase 1 1 3O Interrupting Rating (Amps) 0.2-50 0.2-30 31-50 0.2-30 Capacity (Amps) 2,000 5,000 2,000 5,000 Approvals and Ratings Table 2 UL/CSA Switch Number A Voltage 50/60 Hz. 125 Current (Amps) 10 Terminals WxTxL .093 x .020 x .250 (2.36 x .51 x 6.40) VDE Switch Number V1 V2 V3 Voltage 50/60 Hz. 250 250 250 Current (Amps) 10 5 0.1 Terminals WxTxL .110 x .020 x .280 (2.79 x .51 x 7 .11) Time vs. Current Trip Curves For W6 Series and W9 Series AC 50/60 Hz. DC & 50/60 Hz. 400 Hz. 10,000 1000 CURVE 0 NON-TIME DELAY TRIP TIMES OVERLOAD @ 50/60 Hz. & DC @ 400 Hz. 125% 150% 200% 400% 600% 800% 100 ms max. 55 ms max. 30 ms max. 15 ms max. 12 ms max. 12 ms max. May Trip 100 ms max. 30 ms max. 15 ms max. 12 ms max. 12 ms max. 10,000 1000 CURVE 2 AC VOLTAGE 50/60 Hz. OVERLOAD TRIP TIMES (SEC.) 125% 200% 400% 600% 800% 1000% 10 - 150 2.2 - 20 .2 - 2 .03 - .75 .007 - .15 .005 - .04 10,000 1000 CURVE 3 AC VOLTAGE 50/60 Hz. OVERLOAD TRIPTIMES (SEC.) 125% 200% 400% 600% 800% 1000% 1 - 15 .15 - 1.5 .03 - .25 .007 - .15 .003 - .08 .003 - .04 TIME IN SECONDS TIME IN SECONDS 100 10 1 .1 .01 100 10 1 .1 .01 TIME IN SECONDS 100 10 1 .1 .01 .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING 10,000 1000 MOTOR START CURVE 10 HIGH INRUSH 50/60 Hz. AC OVERLOAD TRIP TIMES (SEC.) 125% 40 - 500 200% 9 - 100 400% 2 - 20 600% .8 - 10 800% .1 - 4.5 1000% .009 - 2 10,000 1000 CURVE 12 HIGH INRUSH 50/60 Hz. OVERLOAD TRIP TIMES (SEC.) 125% 200% 400% 600% 800% 1000% 10 - 150 3 - 25 .5 - 2.5 .15 - 1 .015 - .7 .009 - .35 10,000 1000 CURVE 13 HIGH INRUSH 50/60 Hz. OVERLOAD TRIP TIMES (SEC.) 125% 200% 400% 600% 800% 1000% .8 - 30 .15 - 2.5 .03 - .3 .02 - .15 .009 - .12 .009 - .09 TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS www..com 100 10 1 .1 .01 .001 0 100 10 1 .1 .01 100 10 1 .1 .01 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING DC 10,000 1000 CURVE 2 DC VOLTAGE OVERLOAD TRIP TIMES (SEC.) 125% 200% 400% 600% 800% 1000% 2 - 55 .60 - 8 .1 - 1.5 .02 - .5 .004 - .05 .004 - .025 10,000 1000 CURVE 3 DC VOLTAGE OVERLOAD TRIP TIMES (SEC.) 125% 200% 400% 600% 800% 1000% .6 - 7 .16 - 1.5 .03 - .25 .01 - .13 .004 - .05 .003 - .015 10,000 1000 CURVE 53 DC HIGH INRUSH OVERLOAD TRIP TIMES (SEC.) 125% 80 - 700 200% 15 - 150 400% 2 - 20 600% .70 - 10 800% .10 - 3 1000% .01 - .1 TIME IN SECONDS TIME IN SECONDS 100 10 1 .1 .01 100 10 1 .1 .01 TIME IN SECONDS 100 10 1 .1 .01 .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING AC/DC 10,000 1000 AC 400 Hz. CURVE 34 DC, 50/60 Hz. STANDARD DELAY OVERLOAD TRIP TIMES (SEC.) 135% 200% 400% 600% 800% 1000% 1 - 90 .60 - 20 .095 - 2 .02 - .95 .002 - .45 .002 - .09 10,000 1000 CURVE 2 AC VOLTAGE 400 Hz. OVERLOAD TRIP TIMES (SEC.) 150% 200% 400% 600% 800% 1000% 5 - 60 2.2 - 20 .3 - 3.2 .01 - .17 .006 - .06 .005 - .045 10,000 1000 CURVE 3 AC VOLTAGE 400 Hz. OVERLOAD TRIP TIMES (SEC.) 150% 200% 400% 600% 800% 1000% .55 - 5.5 .18 - 2 .02 - .2 .006 - .075 .004 - .05 .004 - .035 TIME IN SECONDS 100 10 1 .1 .01 TIME IN SECONDS 100 10 1 .1 .01 TIME IN SECONDS 100 10 1 .1 .01 .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT 135 OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING Note: For instantaneous curves for all voltages refer to Curve 0 Non-Time Delay under the AC 50/60 Hz. heading. Pulse Tolerance Specifications Pulse tolerance is defined as a single pulse of a half sine wave (1/2 cycle or 8 milliseconds) that will not trip the breaker. An inertia wheel for increased pulse tolerance is available by specifying "P" after the time delay curve number in the ordering information. The table at right lists pulse tolerance values of standard and inertia delay models. Time Delay Curve 2 3 10 12 13 2 3 Pulse Tolerance Value Standard 7 .5 6 18 18 18 6.5 5.5 Inertia Delay 18 18 30 30 30 18 18 Voltage AC 50/60 Hz. AC 400 Hz. To determine pulse tolerance multiply breaker rating by value in table. For example, a 2A breaker with time delay curve 3 has a standard pulse tolerance of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance of 36A (2A x 18). Ordering Information W6 Series Typical Part No. 1. Circuit Breaker Mounting: W = #6-32 mounting threads. M = M3.0 x 0.5 mounting threads. X = Snap-in mounting. (Not available in rocker actuated models.) 2. Number of Poles: 67 = Single pole 68 = Two pole 69 = Three pole X = Series trip 9 = Red toggle B W 67- X 2 Q 1 2- 20 70 = Four pole 3. Circuit Function: (Only X is VDE approved) A = Series trip with auxiliary switch (.093" QC) 4. Actuator: (One actuator per pole) 1 = Black toggle 3 = Black rocker 2 = White toggle 4 = White rocker 5 = Red rocker 6 = Grey rocker 5. Termination: Q = .250" QC (DIN 46 244) 25A Max. VDE Note: "T" termination must be used for all ratings of 31 amps or above. S = #8-32 screw T = #10-32 screw 6. Maximum Line Voltage: (See Table 1 for current ranges) UL/CSA 1 = 277VAC, 50/60 Hz. VDE TYPES 2 = 277/480 TYPES 3 = 250VAC, 400 Hz. 5 www..com= 65VDC 7 = AC/DC 277VAC or 65VDC (Delay curve 34 must be specified.) 7. Time Delay Curve: 0 = Instantaneous 2 = Standard delay 3 = Short delay 53 = DC high inrush 8. Amp Rating: 0.20 0.50 0.25 0.75 1.0 1.5 2.0 2.5 1 = 250VAC, 415/240VAC 5 = 65VDC 7 = AC/DC 250VAC, 415/240VAC, 65VDC (Delay curve 34 must be specified.) 10 = AC high inrush (Motor start) 12 = AC high inrush version of #2 13 = AC high inrush version of #3 34 = Combination AC/DC standard delay 3.0 3.5 4.0 5.0 6.0 7 .0 7 .5 8.0 Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve, See delay curve section for availability and details. 9.0 10.0 11.0 12.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 Consult factory for other values. 9. VDE Approval: (See Table 2 for auxiliary switch ratings) Blank = UL/CSA approved breaker V = VDE approved breaker without auxiliary switch V1 = VDE approved breaker with 10 amp VDE auxiliary switch W67-A2Q12-5 W67-A2Q12-10 W67-X2Q10-3 W67-X2Q10-5 W67-X2Q12-2 W67-X2Q12-3 W67-X2Q12-5 W67-X2Q12-7 W67-X2Q12-10 W67-X2Q12-15 W67-X2Q12-20 W67-X2Q12-30 W67-X2Q13-1 W67-X2Q13-2 W67-X2Q13-3 W67-X2Q13-10 W67-X2Q13-15 W67-X2Q13-20 V2 = VDE approved breaker with 5 amp VDE auxiliary switch V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery. W67-X2Q13-25 W67-X2Q13-30 W67-X2Q50-5 W67-X2Q50-10 W67-X2Q52-5 W67-X2Q52-10 W67-X2Q52-15 W67-X2Q52-20 W67-X2Q52-30 W67-X2Q110-15 W67-X2Q110-20 W68-X2Q12-3 W68-X2Q12-5 W68-X2Q12-7 W68-X2Q12-10 W68-X2Q12-15 W68-X2Q12-20 W68-X2Q12-25 W68-X2Q12-30 W68-X2Q13-15 W68-X2Q110-10 W68-X2Q110-20 W69-X2Q12-5 W69-X2Q12-10 W69-X2Q12-15 W69-X2Q12-20 W69-X2Q12-25 W69-X2Q12-30 W69-X2Q110-20 W69-X2Q110-30 Ordering Information W9 Series 1. Circuit Breaker Mounting: W = #6-32 mounting threads. 2. Number of Poles: 91 = Single pole Typical Part No. M = M3.0 x 0.5 mounting threads. 93 = Three pole X = Series trip 94 = Four pole B W 91- X 1 1 2- 20 92 = Two pole 3. Circuit Function: (Only X is VDE approved) A = Series trip with auxiliary switch (.093" QC) 4. Actuator: (One actuator per pole): 1 = Black toggle 2 = White toggle 5. Maximum Line Voltage: (See Table 1 for current ranges) UL/CSA 1 = 277VAC, 50/60 Hz. VDE 1 = 250VAC, 415/240VAC TYPES 2 = 277/480 TYPES 5 = 65VDC 3 = 250VAC, 400 Hz. 7 = AC/DC 250VAC, 415/240VAC, 65VDC 5 = 65VDC (Delay curve 34 must be specified.) 7 = AC/DC 277VAC or 65VDC (Delay curve 34 must be specified.) 6. Time Delay Curve: 0 = Instantaneous 2 = Standard delay 3 = Short delay 53 = DC high inrush 7. Amp Rating: 0.20 0.75 0.25 1.0 0.50 1.5 10 = AC high inrush (Motor start) 12 = AC high inrush version of #2 13 = AC high inrush version of #3 34 = Combination AC/DC standard delay 2.0 2.5 3.0 3.5 4.0 5.0 6.0 7 .0 7 .5 8.0 9.0 10.0 Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve. See delay curve section for availability and details. 11.0 12.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 Consult factory for other values 8. VDE Approval: (See Table 2 for auxiliary switch ratings) Blank = UL/CSA approved breaker V = VDE approved breaker without auxiliary switch V1 = VDE approved breaker with 10 amp VDE auxiliary switch V2 = VDE approved breaker with 5 amp VDE auxiliary switch V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery. W91-X112-1 W91-X112-2 W91-X112-3 W91-X112-5 W91-X112-7 W91-X112-10 W91-X112-15 W91-X112-20 W91-X112-40 W91-X112-50 W91-X113-5 W91-X113-10 W91-X113-15 W91-X150-5 W91-X152-10 W91-X152-15 W91-X152-20 W91-X152-30 W91-X152-40 W91-X152-50 W91-X1110-20 W92-X112-1 W92-X112-2 W92-X112-3 W92-X112-5 W92-X112-7 W92-X112-10 W92-X112-15 W92-X112-20 W92-X112-25 W92-X112-30 W92-X112-40 W92-X112-50 W92-X113-15 W92-X113-20 W92-X1110-20 W92-X1110-30 W93-X112-5 W93-X112-10 W93-X112-15 W93-X112-20 W93-X112-25 W93-X112-30 W93-X112-40 W93-X112-50 W93-X1110-20 W93-X1110-30 Outline Dimensions - Toggle Actuator Models. W6 Series Panel Mounting Cutout .235 (5.97) LINE A 1.640 (41.66) .245 (6.22) O .625 +.010 -.000 15.88 +0.25 -0.00 1 PER POLE .750 (19.05) O N ( ) 1.660 (42.16) 29 1.530 (38.86) OFF B L AD O 30 1.048 (26.62) www..com 2.040 (51.82) .67 (17 .02) O .156 (3.96) [2 PLACES PER POLE] W6 Series 1 Pole O .590 (15.00) .750 (19.05) 1.500 (38.10) 2.250 (57 .15) 3.000 (76.20) 2 Pole 3 Pole 4 Pole 2.000 (50.80) 1.22 (31.00) 1.660 (42.16) 1.05 (26.67) 6.32 TH'D. .14 (3.56) DP TYP . . M3 X 0.5 OPTIONAL Note: Multi-pole models furnished with separate handle tie hardware. VDE Models W/Screw Terminals UL/CSA Models W/Screw Terminals .235 (5.9) 2.032 (51.61) UL/CSA/VDE Models W/Aux. Switch 2.38 "A" STYLE (60.45) LINE .827 (20.85) 1.058 (26.87) C NO NC LINE LINE .416 (10.57) 1.530 (38.86) LOAD LOAD LOAD Notes: 1. Terminal protrusion dimensions are referenced from back of mounting panel. 2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79) thick x .377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35) screw type. 3. Panel mounting cutout detail mtg. detail tol.: .005 (.13) unless noted. Add additional cutouts to correspond to number of poles. Outline drawing tolerance .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters. Outline Dimensions - Rocker Actuator Models W6 Series 1.640 (41.66) .390 (9.91) .180 (4.57) LOAD 1.530 (38.86) LINE A D 2.000 (50.80) .388 (9.86) 2.600 (66.04) .805 (20.45) .375 (9.53) 1 Pole .750 (19.05) 2, 3 & 4 Pole 3.000 (76.20) 2.250 (57 .15) 1.500 (38.10) 2 POLE 3 POLE 4 POLE 1.30 (33.0) 1.660 (42.16) ON OFF ON OFF ON OFF ON OFF ON OFF .235 (5.97) 2.430 (61.72) TAPPED FOR #6-32 M3 X 0.5 OPTIONAL .375 (9.53) .750 (19.05) .750 (19.05) .750 (19.05) Panel Mounting www..com Cutout .750 (19.05) .375 (9.53) .750 (19.05) .750 (19.05) .205 (5.21) VDE Rocker Marking .750 (19.05) .375 (9.53) 1.250 (31.75) 1.660 (42.16) 2.000 (50.80) I O .388 (9.86) 2.600 (66.04) Notes: 1. Outline drawing tolerance .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters. 2. Mounting Detail Tol.: .005 (.13) unless noted 1 POLE 2 POLE 3 POLE 4 POLE .750 (19.05) 1.500 (38.10) 2.250 (57 .15) 3.000 (76.20) O .156 (3.96) TYP 2 . PER POLE TAPPED FOR #6-32 M3 X 0.5 OPTIONAL Outline Dimensions - Snap-in Mounted Models W6 Series 1.640 (41.66) .245 (6.22) 1 Pole .750 (19.05) 2 Pole 1.500 (38.10) 3 Pole 2.250 (57 .15) .235 (5.97) .128 (3.25) O N ON 29 1.110 (28.19) ON ON ON ON ON 1.530 (38.86) OFF 30 2.650 (67 .31) OFF OFF OFF OFF OFF OFF 2.040 (51.82) .67 (17 .02) 4 Pole Panel Mounting Cutout 1 Pole .770 (19.6) 1.525 (38.7) 2 Pole 2.280 (57 .9) 3 Pole 3.040 (77 .2) 3.000 (76.20) ON ON ON ON 2.187 (55.55) OFF Notes: Mounting Detail Tol.: .005 (.13) unless noted Panel Thickness: .047 (1.2) to .110 (2.8) OFF OFF OFF Outline Dimensions W9 Series Series Trip Model .281 (7 .14) 1.845 (46.86) .313 (7 .95) Series Trip Model .750 (19.05) .375 (9.53) .375 (9.53) .750 (19.05) .750 (19.05) .750 (19.05) .398 (10.77) LINE ON 29 ON ON 1.940 (49.28) OFF LOAD .14 2.10 (3.56) (53.34) 2.50 (64.00) 30 OFF OFF .218 (5.54) 2.065 (52.45) ON ON ON ON ON ON ON ON 1.438 (36.53) 2.50 OFF OFF OFF OFF OFF OFF OFF OFF (63.5) #10-32 STUD TERMINATION 1 POLE TAPPED #6-32 X .16 (4.06) DEEP M3 X 0.5 OPTIONAL .74 (18.8) 2 POLE 1.500 (38.10) 2.250 3POLE (57 .15) 3.000 (76.20) 4 POLE Series Trip Model With Common Enclosed Auxiliary Switch Panel Mounting Cutout Detail .750 (19.05) .732 (18.59) .750 (19.05) Notes: 1. Terminal protrusion dimensions are referenced from the back of the mounting panel. 2. Mounting detail tolerance .005 (13) unless noted. 3. Outline drawing tolerance .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters. www..com .281 (7 .14) LINE C NO NC LOAD 2.46 (62.48) 'A' STYLE .750 (19.05) .385 (9.78) .907 (23.04) 1.450 (36.83) 1.940 (49.28) 2.065 (52.45) 2.50 (64.00) 2X O .156 (3.96) PER POLE 3.04 (77 .2) 2.28 (57 .9) .76 (19.3) 1.52 (38.6) 1 POLE 2 POLE 3 POLE 4 POLE Tyco Electronics 700 Westpark Drive Peachtree City, GA 30269-1498 Specifications and availability subject to change without notice. 13C9699 Printed in U.S.A. IH/2-00 |
Price & Availability of W68-XXXXX |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |