![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Presence Sensing Safety Devices Safety Edges SafedgeTM Controllers Specifications Standards Safety Category Approvals Power Supply 251 252 Power Consumption 251 252 Fuses, Internal 251D, 251P 251P 252D EN1760-2, EN954-1, ISO 13849-1, AS4024.5, EN954-1, ANSI B11.19 Cat. 3 per EN954-1 CE marked for all applicable directives, cULus, TuV 24V AC/DC or 110/230V AC 50/60Hz 24V AC/DC 50/60Hz <6VA <4VA 500mA Power Supply, Replaceable 2 x 2A Safety Output, Replaceable 500mA, Resettable 4A on AC, 2A on DC 6K, 12V DC open circuit, 4V DC run condition 1 N.O. 9K 1K 2 N.O. 1 N.O. 1 N.C. 2A/250V AC, 2A/125V AC 1A/30V DC 10mA/10V 13ms Green = Run Yellow = Open Circuit Red = Stop 2500V C in accordance with VDE0110 3 -10C to 55C (-14F to 131F) 90% RH IP40 (NEMA 1) IP65 (NEMA 13) IP20 DIN 0470 1 x 4mm2 (10AWG) stranded 1 x 4mm2 (10 AWG) solid 1 x 1.1mm2 (18AWG) stranded 1 x 1.5mm2 (16AWG) solid Polycarbonate 181g (0.4lbs) 450g (1.0lbs) 650g (1.4lbs) 0.15mm 10-55Hz 10g, 11ms half sine Description The Safedge controllers are designed to operate with the Safedge profiles. The controller continuously monitors the profile for actuation and generates an output signal when the profile is depressed. The Safedge controller provides a low voltage to the profile. When the profile is pressed, the controller detects a change in resistance and turns off its output relays. When pressure is released from the profile, the output relays of the controller return to an on state. The controller has redundant voltage free positively-guided output relays which can be used to interface with a machine control system. The `251' controller comes capable of operating at 24V AC/DC, or 120/230V AC from separate terminals. An internal switch changes the operating voltage from 120V AC to 230V AC. The `252' controller operates at 24V AC/DC. An auxiliary output relay is available to provide a signal about the controller's status. Three LEDs indicate whether the controller is in RUN, STOP or OPEN condition. The controller operates in manual or automatic reset mode. Fuses, External Safety Input Profile Monitoring Maximum Input Impedance Profile Monitoring Circuit Outputs 251 Safety 252 Safety 251, 252 Auxiliary Output Rating Min. Switching Current/Volt. Max. Response Time Indication LEDs Impulse Withstand Voltage Installation Group Pollution Degree Operating Temperature Humidity Enclosure Protection 251D, 252D 251P Terminal Protection Max Conductor Size 251D, 252D 251P Case Material Weight 252D 251D 251P Vibration Shock Features * * * * * * 1 N.O. or 2 N.O. Safety Outputs 1 N.C. Auxiliary Output 24V AC/DC or 120/240V AC Output Monitoring LED Indicators for RUN, STOP and OPEN Automatic/Manual Reset 2-103 Presence Sensing Safety Devices Safety Edges SafedgeTM Controllers Product Selection Housing Type Description Catalogue Number 440F-C251D 35mm DIN Rail Mountable 440F-C252D Surface Mountable 440F-C251P Approximate Dimensions--mm (inches) Dimensions are not intended to be used for installation purposes. 440F-C251D 120 (4.72) 45.5 (1.79) 130 (5.12) 115 (4.53) 440F-C251P 75 (2.95) 440F-C252D 22.5 (0.88) 118 (4.64) 73 (2.87) Pg 16/21 Pg 16/21 86 (3.38) 115 (4.53) 130 (5.12) 35mm DIN Rail Mounting 4 x M4 Mounting Holes Block Diagram L F1 N +Ve X1 X2 Z2 13 23 31 24VDC K2 VR 12V K2 K1 K2 G E -Ve K3 R Z1 K1 K2 K3 K1 K3 K1 ~ K1 Logic Y Q1 Q2 K2 14 24 32 2-104 Presence Sensing Safety Devices Safety Edges SafedgeTM Controllers Typical Wiring Diagrams L1 Reset 24V DC L1 L2 L3 L +Ve Z1 Safedge L1 L2 L3 L Safedge Z2 X1 13 23 31 K1 K2 +Ve Z1 Z2 X1 13 23 31 K1 K2 440F-C251D 440F-C251P 440F-C251D 440F-C251P N - Ve X2 14 K1 24 K2 42 N - Ve 24V Ground X2 14 K1 24 K2 42 M M N Series Terminated, Safedge Input, Manual Reset, Dual Channel Output, Monitored Output Series Terminated, Cascaded, Safedge Input, Automatic Reset, Dual Channel Output, No Output Monitored +24V DC +24V DC Reset L1 L2 L3 L1 L2 L3 + Safedge Safedge Z1 Z2 X1 13 21 K1 K2 Safedge + Z1 Z2 X1 13 21 K1 440F-C252D 440F-C252D 24V Ground X2 14 K1 22 M 24V Ground X2 14 K1 22 M K2 Parallel Terminated, Safedge Input, Manual Reset, Dual Channel Output, Monitored Output Series Terminated, Safedge Input, Automatic Reset, Single Channel Output, No Output Monitored Accessories Description Fuse, 500mA Fuse, 2A Page 14-6 14-2 Catalogue Number 440R-A31562 440A-A09197 2-105 |
Price & Availability of 440R-A31562
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |