|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
www..com P-511-449(V:1) PD057VT1 Revision History Rev. Issued Date 1.0 Jun. 07, 2007 Eng. Revised New Contents www..com The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:2 P-511-449(V:1) PD057VT1 TECHNICAL SPECIFICATION CONTENTS NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ITEM Cover Revision History Contents Application Features Mechanical Specifications Mechanical Drawing of TFT-LCD module Input / Output Terminals Absolute Maximum Ratings Electrical Characteristics Pixel Arrangement Display Color and Gray Scale Reference Interface Timing Power On Sequence Optical Characteristics Handling Cautions PAGE 1 2 3 4 4 4 5 6 7 7 8 9 10 12 12 16 17 18 www..com Reliability Test Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:3 P-511-449(V:1) PD057VT1 1. Application This data sheet applies to a color TFT LCD module, PD057VT1. PD057VT1 module applies to OA product, car TV (must use Analog to Digital driving board), which requires high quality flat panel display. If you must use in severe reliability environment, please don't extend over PVI's reliability test conditions. 2. Features . VGA (640*480 pixels) resolution . Amorphous silicon TFT LCD panel with back-light unit . Pixel in stripe configuration . Thin and light weight . Display Colors 262,144 colors . TTL interface 3. Mechanical Specifications Parameter Screen Size Display Format Display Colors Active Area Pixel Pitch Pixel Configuration Outline Dimension Weight www..com Back-light Surface treatment Display mode Gray scale inversion direction Specifications 5.7 (diagonal) 640 (R,G,B) 480 262,144 115.20 (H) 86.4 (V) 0.18(H) 0.18(V) Stripe 144.0 (W) 104.6(H) 13.0 (D) (typ.) 211.6 2 36-LED Anti-glare + EWV film Normally white 6 o'clock Unit inch dot mm mm mm g The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:4 P-511-449(V:1) PD057VT1 4.Mechanical Drawing of TFT-LCD Module www..com The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:5 P-511-449(V:1) PD057VT1 5.Input / Output Terminals 5-1) TFT-LCD Panel Driving Connector type: ELCO 08-6210-033-340-800A+ , PIN No 33 pins, pitch=0.5mm Pin No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 www..com 24 25 26 27 28 29 Symbol I/O GND I CK I Hsync I Vsync GND R0 I R1 I R2 I R3 I R4 I R5 GND I G0 I G1 I G2 I G3 I G4 I G5 GND I B0 I B1 I B2 I B3 I B4 I B5 GND I ENAB VCC VCC Description GND Clock signal for sampling each data signal Horizontal synchronous signal (neqative) Vertical synchronous signal (neqative) GND RED data signal (LSB) RED data signal RED data signal RED data signal RED data signal RED data signal (MSB) GND GREEN data signal (LSB) GREEN data signal GREEN data signal GREEN data signal GREEN data signal GREEN data signal (MSB) GND Blue data signal (LSB) Blue data signal Blue data signal Blue data signal Blue data signal Blue data signal (MSB) GND Signal to settle the horizontal display position(positive) +3.3V power supply +3.3V power supply Horizontal display mode select signal L Normal ,H Left /Right reverse mode Vertical display mode select signal H Normal ,L Up/Down reverse mode H Normal GND Remark Note5-1 30 R/L I Note5-2 31 U/D I 32 33 V/Q GND I - Note5-1 The horizontal display start timing is settled in accordance with rising of ENAB signal. In case ENAB is fixed "Low",the horizontal start timing is determined as described in 10-2. Dont keep ENAB"High" during operation. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:6 P-511-449(V:1) PD057VT1 Note 5-2 The definitions of U/D & R/L R/L(PIN 30)= Low, U/D(PIN 31)= High R/L(PIN 30)= High , U/D(PIN 31)= Low 5-2) LED Backlight driving Connector type: JST BHR-03VS-1, PIN No 3 pins, pitch=8.0mm Pin No Symbol Description Remark 1 VHigh Power supply for lamp (High voltage side) Red - NC This is electrically opened - 3 VLow Power supply for lamp (Low voltage side) Black Note 5-4: Low voltage side of backlight inverter connects with ground of inverter circuits. www..com 6.Absolute Maximum Ratings: Symbol VI Condition MAX. GND=0V, Ta=25 Unit V Remark Note6-1 Ta=25 -0.3~+4 Ta=25 +3.3V supply voltage VCC 0~+3.6 V Note6-1:CK,R0~R5,G0~G5,B0~B5,Hsync,Vsync,ENAB,R/L,U/D,V/Q Parameters Input Voltage 7.Electrical Characteristics 7-1) Recommended Operating Conditions: Item +3.3V Supply Voltage Symbol VCC Min. Typ. Max. GND=0V, Ta=25 Unit Remark V mVp-p VCC=3.3V V V +3.0 0 0.7 VCC +3.3 - +3.6 100 0.3 VCC VCC Permissive input ripple voltage Input voltage(Low) Input voltage(High) VRF VIL VIH The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:7 P-511-449(V:1) PD057VT1 7-2) Recommended Driving Condition for LED Back Light Ta=25 Typ. Max. Unit Remark Parameter Symbol Min. LED voltage VLED 11.0 11.5 V ILED= 20mA mA Note 7-1 LED current ILED 20 Back Light Power Consumption PLED 2640 2760 mW Note 7-2 Note 7-1 : The LED driving condition is defined for each LED module. (3 LED Serial) Note 7-2 : PLED = VLED-1 * ILED-1 + VLED-2* ILED-2 ..... + VLED-11 * ILED-11+VLED-12 * ILED-12 7-3) Power Consumption Parameters +3.3V Current Dissipation LCD Panel Power Consumption Symbol ICC - Typ. 67 0.22 Max. 100 0.33 Unit mA W Remark Total Power Consumption - 0.484 0.606 W Note 7-3: The power consumption for back light is not included. www..com 8. Pixel Arrangement The LCD module pixel arrangement is stripe configuration. 640 478 479 480 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:8 P-511-449(V:1) PD057VT1 9. Display Color and Gray Scale Reference Input Color Data Green Color Red Blue R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 Basic Colors Black Red (63) Green (63) Blue (63) Cyan Magenta Yellow White Red (00) Red (01) Red (02) Darker 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 1 0 1 0 0 0 1 1 1 0 1 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 1 0 1 0 1 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 1 0 0 0 Red Brighter Red (61) Red (62) Red (63) Green (00) Green (01) Green (02) Darker 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Green www..com Brighter Green (61) Green (62) Green (63) Blue (00) Blue (01) Blue (02) Darker 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 Blue Brighter Blue (61) Blue (62) Blue (63) 000000000000111101 000000000000111110 000000000000111111 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:9 P-511-449(V:1) PD057VT1 10. Interface Timing 10-1) Timing Parameters Note 10-1 : In case of low-frequency, the deterioration of display quality, flicker etc., may occur. 10-2) Display Position in horizontal direction Display position in horizontal direction is designated by rising timing of ENAB signal. www..com When ENAB is fixed to "Low", the horizontal display will starts from 144th clock after HS falling. 10-3) Display Position in vertical direction Display start position in vertical direction is fixed to the 35 line. The ENAB signal does not relate to Vertical display position. th The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:10 P-511-449(V:1) PD057VT1 10-4) Timing Diagram THWh Tcph Tcwh *Only when enable terminal is fixed " Low" Tcwl Tdhd Tdsu Horizontal invalid data period D638 D639 D640 Horizontal invalid data period THs Tesu Twv www..com TSTV Vertical invalid data period DH1 DH2 DH3 DH479 DH480 Vertical invalid data period The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:11 P-511-449(V:1) PD057VT1 11. Power On Sequence VDD 3.0V Signal*3 3.0V 0.3V t1 t2 t3 OFF 10ms 1. 0 2. 0 3. 0 t1 t2 t3 20ms 50ms 1s Back Light ON 10ms OFF 12. Optical Characteristics 12-1) Specification: Parameter Symbol Horizontal Condition MIN. TYP. MAX. Ta=25 Unit Remarks deg 75 CR 10 80 - Viewing www..com Angle Vertical (to 6 o'clock) (to 12 o'clock) 65 70 - deg Note 12-1 45 50 - deg Contrast Ratio CR At optimized viewing angle 400 600 - - Note 12-2 Response time Rise Tr Fall Tf =0 - 15 30 ms =0 25 Brightness - =0/ 450 500 50 - ms Note 12-3 cd/ Note 12-4 Luminance Uniformity U% 80 85 - % Note 12-5 White Chromaticity x 0.26 0.30 0.34 - y 0.29 =0 0.33 0.37 - Cross Talk - LED Life Time - 20000 - 3.5 - % Note 12-7 hr Note 12-6 Note 12-1: The definitions of viewing angles are as follow The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:12 P-511-449(V:1) PD057VT1 12 o clock Lamp connector 3 o clock 9 o clock Note 12-2: The definition of contrast ratio 6 o clock = Note 12-3: Definition of Response Time Tr and Tf: W hite Black W hite 100% www..com90% Note 12-4: All optical measurements shall be performed after backlight being turned-on for 30 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:13 Brightness 10% 0% Tr Tf P-511-449(V:1) PD057VT1 mins. The optical characteristics shall be measured in dark room (ambient illumination on panel surface less than 1 Lux). The measuring configuration shows as following figure. Photometer (TOPCON BM-5A or BM-7 fast) Note 12-5: The uniformity of LCD is defined as U= The Minimum Brightness of the 9 testing Points The Maximum Brightness of the 9 testing Points Luminance meter: BM-5A or BM-7 fast (TOPCON) Measurement distance: 500 mm +/- 50 mm Ambient illumination: < 1 Lux Measuring direction: Perpendicular to the surface of module www..com The test pattern is white (Gray Level 63). 500 mm +/- 50 mm 1/6 2/6 Field = 1 TFT-LCD module DC/AC Inverter Optical characteristics measuring configuration 1/6 2/6 2/6 1/6 2/6 1/6 Note 12-6: The "LED Life time " is defined as the module brightness decrease to 50% original Brightness that the ambient temperature is 25 and ILED = 20mA. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:14 P-511-449(V:1) PD057VT1 YA-YB 100% YA Note 12-7: Cross Talk (CTK) = YA: Brightness of Pattern A YB: Brightness of Pattern B Luminance meter : BM 5A or BM-7 fast (TOPCON) Measurement distance : 500 mm +/- 50 mm Ambient illumination : < 1 Lux Measuring direction : Perpendicular to the surface of module Pattern A (Gray Level 31) Pattern B (Gray Level 31, central black box exclusive) YA YB 1/3 1/3 1/3 1/3 : Measuring Point (A and B are at the same point.) 1/3 1/3 Black (Gray Level 0) www..com The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:15 P-511-449(V:1) PD057VT1 13. Handling Cautions 13-1) Mounting of module a) Please power off the module when you connect the input/output connector. b) Polarizer which is made of soft material and susceptible to flaw must be handled carefully. c) Protective film (Laminator) is applied on surface to protect it against scratches and dirts. It is recommended to peel off the laminator before use and taking care of static electricity. 13-2) Precautions in mounting a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled, wipe it with soft dry cloth. b) Wipe off water drops or finger grease immediately. Long contact with water may cause discoloration or spots. c) TFT-LCD module uses glass which breaks or cracks easily if dropped or bumped on hard surface. Please handle with care. d) Since CMOS LSI is used in the module. So take care of static electricity and earth yourself when handling. 13-3) Adjusting module a) Adjusting volumes on the rear face of the module have been set optimally before shipment. b) Therefore, do not change any adjusted values. If adjusted values are changed, the specifications described may not be satisfied. 13-4) Others a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours. b) Store the module at a room temperature place. c) The voltage of beginning electric discharge may over the normal voltage because of leakage current from approach conductor by to draw lump read lead line around. d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel. Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet. Wash it out immediately with soap. e) Observe all other precautionary requirements in handling general electronic components. f) Please adjust the voltage of common electrode as material of attachment by 1 module. 13-5) Polarizer mark The polarizer mark is to describe the direction of wide view angle film how to match up with the rubbing direction. www..com The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:16 P-511-449(V:1) PD057VT1 14. Reliability Test No Test Item Test Condition Remark 1 High Temperature Storage Test Ta = +80 , 240 hrs 2 Low Temperature Storage Test Ta = -40 , 240 hrs 3 High Temperature Operation Test Ta = +70 , 240 hrs 4 Low Temperature Operation Test Ta = -30 , 240 hrs 5 High Temperature & High Humidity Ta = +60 , 90%RH, 240 hrs Operation Test (No Condensation) 6 Thermal Cycling Test (non-operating) -20 +70 , 200 Cycles Vibration Test 7 (non-operating) Shock Test 8 (non-operating) 30 min 30 min Frequency: 10 ~ 57 HZ /Vibration Width:0.075mm 2 58-500 Hz / Gravity: 9.8m/s Sweep time: 11 minutes Test period: 3 hrs for each direction of X, Y, Z 2 Gravity: 490m/s * 6ms Direction: X, Y, Z 3 times for each direction 150pF 330 Electrostatic Discharge Test 9 (non-operating) Air 15KV Contact 8KV 10 times/point 9 points/panel face Ta: ambient temperature Note: The protective film must be removed before temperature test [Criteria] In the standard conditions, there is not display function NG issue occurred. (Including line defect, no image) All the cosmetic specification is judged before the www..com reliability stress. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17 P-511-449(V:1) PD057VT1 15. Packing Diagram www..com The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:18 |
Price & Availability of PD057VT1 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |