 RI-02 Series Dry Reed Switch
RI-02 Series Ultra-miniature dry-reed switch hermetically sealed in a gasfilled envelope. Single-pole, single-throw (SPST) type, having normally open contacts, and containing two magnetically actuated reeds. The switch is of the double-ended type and may be actuated by an electromagnet, a permanent magnet or a combination of both. The device is intended for use in relays, sensors, pulse counters or similar devices. RI-02 Series Features Ideal for General Purpose reed relays and sensors Contact layers: ruthenium on gold Superior glass-to-metal seal and blade alignment
General data for all models RI-02
AT-Customization / Preformed Leads
Dimensions in inches (mm) Loaded conditions (resistive load: 5V; 100 mA; operating frequency: 125 Hz)
Besides the standard models, customized products can also be supplied offering the following options: ! Operate and release ranges to customer specification ! Cropped and/or preformed leads
Coils
All characteristics are measured using the Philips standard coil. For definitions of the Philips Standard Coil, refer to "Application Notes" in the Reed Switch Technical & Application Information Section of this catalog.
Life expectancy and reliability
Life expectancy: min. 2 x 106 operations with a failure rate of less than 10-8 with a confidence level of 90%. End of life criteria: Contact resistance > 1 after 2.5 ms Release time > 1 ms (latching or contact sticking).
Loaded conditions (resistive load: 20V; 500 mA; operating frequency: 125 Hz)
Life expectancy: min. 2 x 106 operations with a failure rate of < 10-7 with a confidence level of 90%. End of life criteria: Contact resistance > 2 after 2.5 ms Release time > 2.5 ms (latching or contact sticking). Switching different loads involves different life expectancy and reliability data. Further information is available on request.
The life expectancy data given below are valid for a coil energized at 1.25 times the published maximum operate value for each type in the RI-02 series.
No-load conditions (operating frequency: 100 Hz)
Life expectancy: min.108 operations with a failure rate of less than 2 x10-10 with a confidence level of 90%. End of life criteria: Contact resistance > 1 after 2 ms Release time > 2ms (latching or contact sticking).
122
COTO TECHNOLOGY (USA) Tel: (401) 943-2686 / Fax (401) 942-0920
6
(Europe) Tel: +31-45-5439343 / Fax +31-45-5427216
RI-02 Series Dry Reed Switch
Mechanical Data
Operating and Storage Temperature
Contact arrangement is normally open; lead finish is tinned; net mass is approximately 90mg; and can be mounted in any position.
Shock
Operating ambient temperature; min: -55C; max: +125C. Storage temperature; min: -55C; max: +125C. Note: Temperature excursions up to 150C may be permissible. For more information contact your nearest Coto Technology sales office.
Soldering
The switches are tested in accordance with "IEC 68-227", test Ea (peak acceleration 150 G, half sinewave; duration 11 ms). Such a shock will not cause an open switch (no magnetic field present) to close nor a switch kept closed by an 80 AT coil to open.
Vibration
The switches are tested in accordance with "IEC 68-226", test Fc (acceleration 10G; below cross-over frequency 57 to 62 Hz; amplitude 0.75 mm; frequency range 10 to 2000 Hz; duration 90 minutes.) Such a vibration will not cause an open switch (no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open.
Mechanical Strength
The switch can withstand soldering heat in accordance with "IEC 68-2-20", test Tb, method 1B: solder bath at 350 10 C for 3.5 0.5 s. Solderability is tested in accordance with "IEC 68-2-20" test Ta, method 3: solder globule temperature 235C; ageing 1b: 4 hours steam.
Welding
The leads can be welded.
Mounting
The robustness of the terminations is tested in accordance with "IEC 68-2-21", test Ua1 (load 10 N).
The leads should not be bent closer than 1 mm to the glass-to-metal seals. Stress on the seals should be avoided. Care must be taken to prevent stray magnetic fields from influencing the operating and measuring conditions.
6 E-mail: sales@cotorelay.com
For Most Recent Data, Consult the Coto Technology Website: www.cotorelay.com
123


▲Up To Search▲   

 
Price & Availability of RI-02

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X