 a D . w w w Specification for
aS t
ee h
4U t
om .c
UB084S01-2 8.4" SVGA (800x600) with touch panel Color TFT
Feb.2001
w
w
.D w
t a
S a
e h
t e
U 4
.c
m o
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 info@datamodul.com - www.datamodul.com
w
w
w
.D
a
aS t
ee h
4U t
om .c
Record of Revision
Version 1 Revise Date 23/Feb./2001 Page First draft. Content
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Contents: A. Physical P2 specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B. Electrical P3 specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. Pin P3
assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. Absolute maximum P4 ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. Electrical P5 characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . a. Typical operating P5 conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . b. Display color v. s. input data P6 signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . c. Input signal P7 timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d. Display P7 position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . e. Backlight P8 unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C. Optical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D. Touch panel specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E. Reliability test items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F. Display quality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G. Handling precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H. Packing form. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix:
P9 P11 P12 P12 P12 P13
Fig.1 LCM outline P14 dimensions .......... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fig.2 Timing P15 chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
A. Physical specifications
NO. 1 2 3 4 5 6 7 Item Display resolution(pixel) Active area(mm) Screen size(inch) Pixel pitch(mm) Color configuration Overall dimension(mm) Weight(g) Specification 800(H)x600(V) 170.4(H)x127.8(V) 8.4(Diagonal) 0.213(H)x0.213(V) R. G. B. Vertical stripe 203.0(W)x142.5(H)x7.5(D) 310 10 Note 1 Remark
Note 1: Refer to Fig. 1.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
B. Electrical specifications
1.Pin assignment (1).Input signal interface
Pin no 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Symbol VCC VCC GND GND RxIN0RxIN0+ GND RxIN1RxIN1+ GND RxIN2RxIN2+ GND CKINCKIN+ GND NC NC GND GND Function +3.3 V power supply +3.3 V power supply Ground Ground LVDS receiver signal channel 0 Ground LVDS receiver signal channel 1 Ground LVDS receiver signal channel 2 Ground LVDS receiver signal clock Ground No Connection No Connection Ground Ground Etc.
CN1 (20P) connector: HRS DF 19K-20P-1H or compatible
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
(2) LVDS transmitter/receiver signal mapping
Symbol TxIN0 TxIN1 TxIN2 TxIN3 TxIN4 TxIN5 TxIN6 TxIN7 TxIN8 TxIN9 TxIN10 TxIN11 TxIN12 TxIN13 TxIN14 TxIN15 TxIN16 TxIN17 TxIN18 TxIN19 TxIN20 TxCLKIN R0 R1 R2 R3 R4 R5 G0 G1 G2 G3 G4 G5 B0 B1 B2 B3 B4 B5 Hs Vs DE CLK Red data (LSB) Red data Red data Red data Red data Red data (MSB) Green data (LSB) Green data Green data Green data Green data Green data (MSB) Blue data (LSB) Blue data Blue data Blue data Blue data Blue data (MSB) Horizontal sync. Vertical sync. Data enable Clock Dot clock 6 bits blue display data 6 bit green display data 6 bit red display data Function
2. Absolute maximum ratings
(GND
Values Min. Max. 4 VCC+0.3 +60 +70 VDC VDC * * At 25* At 25* Note 1 Note 1 -0.3 -0.3 0 -20 Unit
= 0 V)
Parameter Power voltage Input signal voltage Operating temperature Storage temperature Symbol VCC VLH Top T ST Remark
Note 1: The relative humidity must not exceed 90% non-condensing at temperatures of 40* or less. At temperatures greater than 40*, the wet bulb temperature must not exceed 39 *. When operate at low temperatures, the brightness of CCFL will drop and the lifetime of CCFL will be reduced. Note 2: The unit should not be exposed to corrosive chemicals.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
3. Electrical characteristics a. Typical operating conditions
Item Power supply voltage Input voltage Current consumption Inrush current Internal logic Low voltage High voltage Power ripple voltage I Symbol VCC IA IB
RUSH
Min. 3.0 0 0.7VCC -
Typ. 3.3 220 -
Max. 3.6 300 1500 0.3 VCC VCC 100
Unit V mArms mArms mApeak
Remark
Note 1 Note 2
VIL VIH VRP
mVp-p
Note 1:Effective value (mArms) at VCC = 3.3 V/25*.
IA IB Black (0) 64 Gray (7) 64
White 64 Grayscale
Black Vertical stripe line
Note 2: Refer to the following power-on condition.
90%
Vcc 10% Ton=470*s10%
Sequence of Power-on/off and signal-on/off
T3 T4 T2
Power
T5
0ms*T1*70msec 0ms*T2*70msec 300msec*T3 300msec*T4 T5*10msec
T1
Input signal
Apply the lamp voltage within the LCD operating range. When the backlight turns on before the LCD operation or the LCD turns off before the backlight turns off, the display may momentarily become abnormal.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Caution The above on/off sequence should be applied to avoid abnormal function in the display. In case of handling: Make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector. b. Display color vs. input data signals
Display colors Black Blue Red Magenta Green Cyan Yellow White Black Dark * * bright Data signal (0 : Low level, 1: High level) R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 1 0 0 1 1 0 0 1 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0
Basic colors
Red grayscale
Red Black Dark * * bright
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
0 1 1 0 0 0
1 0 1 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 1
0 0 0 0 1 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Green grayscale
Green Black Dark * * bright
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
0 1 1 0 0 0
1 0 1 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 1
0 0 0 0 1 0
Blue grayscale
Blue
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
1 1 1
1 1 1
1 1 1
1 1 1
0 1 1
1 0 1
Note: Each basic color can be displayed in 64 gray scales using the 6 bit data signals. By combining the 18-bit data signals(R, G, B), the 262, 144 colors can be achieved on the display.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
c. Input signal timing Timing diagrams of input signal are shown in Fig 2. (1). Timing characteristics of input signals DE mode
Item Clock frequency Horizontal blanking Horizontal display period Horizontal sync. period Vertical blanking Vertical display width Vertical sync. period Symbol Fck Thb1 Thd Th Tvb1 Tvd Tv Min. 38 235 1035 10 610 Typ. 40 256 800 1056 28 600 628 Max. 42 500 1300 150 750 Unit MHz Clk Clk Clk Th Th Th Remark
(2). The timing condition of LVDS
Item The differential level The common mode input voltage The input setup time The input hold time Symbol *VID* VIC tsu1 th1 Min. 0.1 *VID* 2 0.5 0.5 Typ. 2.4* Max. 0.6 *VID* 2 Unit V V ns ns Remark
VID
VID = VIAP - VIAM
VIAP
VIAM
tsu1 th1
Ri Gi Bi i=0~5 DE 7xCLK d. Display position
D( 1,1 ) D( 1,2 ) . . . D( 1,Y ) . . . D( 1,599 ) D( 1,600 ) D( 2,1 ) D( 2,2 ) D( 2,Y ) D( 2,599 ) D( 2,600 ) ...... ...... ...... ...... ...... ...... ...... D( X,1 ) D( X,2 ) . . . D( X,Y ) . . . D( X,599 ) D( X,600 ) ...... ...... ...... ...... ...... ...... ...... D( 799,1 ) D( 799,2 ) . . . D( 799,Y ) . . . D( 799,599) D( 799,600) D( 800,1 ) D( 800,2 ) . . . D( 800,Y ) . . . D( 800,599 ) D( 800,600)
DATA MODUL INC. - 1767-46 Veterans Memorial Highway -
Islandia NY 11749 - Tel 631-951-0800 - Fax 631-951-2121 -
info@datamodul.com
e.Backlight unit The backlight system is an edge-lighting type with a CCFT(Cold Cathode Fluorescent Tube). The characteristics of a single lamp are shown in the following tables.
Parameter Lamp voltage Lamp current Power consumption Lamp starting voltage Frequency Lamp life time Symbol VL IL PL VS FL LL Min. 441 3 50 10000 Typ. 490 4.6 2.25 60 20000 Max. 539 5.1 910(T=0*) 700(T=25*) 80 Unit Vrms mArms W Vrms KHZ Hr Remark Note 1 Note 1 Note 2 Note 3 Note 4 Note 1, 5
Note 1: T= 25* Note 2: Inverter should be designed with the characteristic of lamp. When you are designing the inverter, the output voltage of the inverter should comply with the following conditions. (1). The area under the positive and negative cycles of the waveform of the lamp current and lamp voltage should be area symmetric (the symmetric ratio should be larger than 90%). (2). There should not be any spikes in the waveform. (3). The waveform should be sine wave as possible. (4). Lamp current should not exceed the maximum value within the operating temperature (It is prohibited to over the maximum lamp current even if operated in the non-guaranteed temperature). When lamp current over the maximum value for a long time, it may cause fire. Therefore, it is recommend that the inverter should have the current limited circuit. Note 3: The inverter open voltage should be designed larger than the lamp starting voltage otherwise backlight may be blinking for a moment after turning on or not be able to turn on. The open voltage should be measured after ballast capacitor. If an inverter has shutdown function it should keep its open voltage for longer than 1 second even if lamp connector is open. Note 4: Lamp frequency may produce interference with horizontal synchronous frequency and this may cause line flow on the display. Therefore lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference. Note 5: Brightness (IL=4.6mA) to be decrease to the 50% of the initial value. Note 6: CN2 connector (backlight): BHSR-02VS-1 (JST) Mating connector: SM02B-BHSS-1-TB (JST)
Pin no. 1 2 Symbol H L Function CCFL power supply(H.V.) CCFL power supply(GND) Remark Cable color: Pink Cable color: White
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
C. Optical specifications - including touch panel( Note 1, Note 2 )
Item Response time Rising time Falling time Contrast ratio(center of screen) Viewing angle Top Bottom Left Right Brightness(center of screen) Color chromaticity(CIE) CR*10 30 10 40 40 90 0.285 *=0 0.310 0.540 0.290 0.270 0.530 0.120 0.090 120 0.315 0.340 0.570 0.320 0.300 0.560 0.150 0.120 0345 0.3700.600 0.350 0.330 0.590 0.180 0.150 1.8 Note 3,8 deg. Note 3,5,7 Symbol Condition Specification Min. 150 Typ. 20 30 200 Max. 40 50 Unit Remark
Tr Tf CR
*=0 *=0
ms
Note 4 Note 3,5
YL Wx Wy Rx Ry Gx Gy Bx By
*=0
nit
Note 3,6 Note 3
White uniformity
*W
Note Note Note Note
1: Ambient temperature = 25*. 2: To be measured in dark room after backlight warm up 30 minutes. 3: To be measured with a viewing cone of 1by Topcon luminance meter BM-5A. 4: Definition of response time: The output signals of BM-7 are measured when the input signals are changed from "Black" to "White" (falling time) and from "White" to "Black" (rising time), respectively. The response time interval between the 10% and 90% of amplitudes. Refer to figure as below.
"Black"
"White"
100% 90%
"White"
Note 5. Definition of contrast ratio:
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Signal(Relative value)
10% 0%
Tr
Tf
Contrast ratio is calculated with the following formula. Contrast ratio (CR)= Brightness on the "white" state Brightness on the "black" state
Note 6: Driving conditions for CCFL: IL=4.6 mA, 60KHz Frequency. Note 7: Definition of viewing angle:
*
Note 8: Definition of white uniformity: White uniformity is calculated with the following formula. Luminance are measured at the following nine points (1~9).
*W =
Maximum Brightness of nine points Minimum Brightness of nine points
D. Touch Panel Specifications
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
1. Operating condition
Item Operating voltage Min. Typ. 5 Max. Unit VDC Remark
2. Electrical characteristic
Item Resistance between terminal Insulation resistance Linearity XH-XL YH-YL X-Y X Y Min. 150 150 20 Typ. 500 500 Max. 1300 1300 1.5 1.5 Unit * * M* % % Remark
3. Mechanical characteristic
Item Pen/Finger input pressure Surface hardness Min. Typ. 3 Max. 120 Description High voltage terminal along X-axis High voltage terminal along Y-axis Low voltage terminal along X-axis Low voltage terminal along Y-axis Unit g H Remark
CN3: FFC tail
Pin. No. 1 2 3 4 Symbol XH YH XL YL
4. Optical characteristic Refer to the C. Optical specifications in page 9/15.
E. Reliability test items (Note 1)
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Test tem High temperature storage 70*, 240Hrs
Test Condition
Remark Note 1, 2, 3
Low temperature storage
-20*, 240Hrs
Note 1, 2, 3
High temperature & high humidity operation
40*, 90%RH, 240Hrs (No condensation)
Note 1, 2, 3
High temperature operation 60*, 240Hrs
Note 1, 2, 3
Low temperature operation
0*, 240Hrs
Note 1, 2, 3
Temperature cycling (non-operation) Electrostatic discharge (non-operation) Vibration (non-operation) Mechanical shock (non-operation)
-20*~70* 1H, 10mins, 1H, 5cycles 150 pF,150*,10kV,1 second, 9 position on the panel, 10 times each place Sweep:1G, 10HZ ~ 500HZ ~ 10HZ /2.5min 2 hours for each direction X, Y, Z 50G/11ms, 200G/2ms, X, Y, Z once for each direction
Note 1, 2, 3
Note 3
Note 1, 2, 3
Note 1, 2, 3
Note 1: Evaluation should be tested after storage at room temperature for one hour. Note 2: There should be no change which might affect the practical display function when the display quality test is conducted under normal operating condition. Note 3: Judgement: 1.Function OK. 2.No serious image quality degradation.
F. Display quality
The display quality of the color TFT-LCD module should be in compliance with the Unipac's OQC inspection standard.
G. Handling precaution
The Handling of the TFT-LCD should be in compliance with the Unipac's handling principle standard.
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
H. Packing form:
LCD Module
Anti-Static Bag
NOTE : 1. Max. Capacity : 30 LCD Modules/Carton. 2. Max. Weight : 12 Kg/Carton. 3. Meas : 600 mm*353mm*210mm.
EPP Cushion
Carton
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Fig.1 LCM outline dimensions
RGB
Invalid X,1 X,2 X,3 X,599 X,600
X,599 X,600
Invalid
Tvbl Tv Fck
Tvd
DE
CLK
3,Y 799,Y 800,Y invalid
RGB
invalid 1,Y 2,Y
800,Y
Thbl
ThTv
Thd (1 pixel / clock)
DE
DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com
Fig.2 Timing chart


▲Up To Search▲   

 
Price & Availability of UB084S01-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X