![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
w w w .D at Sh a et e 4U . om c Specification UB084S01 e h 8.4" SVGA (800 x 600) S ta Color TFT a .D w w w w w .D at Sh a et e 4U t e U 4 .c m o . om c DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 info@datamodul.com - www.datamodul.com w Record of Revision Version Revise Date Page Content 1 26/Jun/2000 First draft. DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com A. Physical specification B. Electrical specifications Contents: 1. Pin assignment 2. Absolute maximum ratings 3. Electrical characteristics a. Typical operating conditions b. Display color v. s. input data signals PAGE ... c. Input signal timing d. Display position e. Backlight driving conditions C. Optical specifications D. Reliability test items E. Display quality F. Handling precaution G. Packing form Appendix: Fig.1 LCM outline dimensions ......... ......... Fig.2 Timing chart : 1/14 P13 P12 P11 P11 P11 P11 P9 P8 P7 P7 P6 P5 P5 P4 P3 P3 P2 PAGE : 2/14 A. Physical specifications NO. 1 2 3 4 5 6 7 Item Specification 800(H) 600(V) 127.8(V) Remark Display resolution(pixel) Active area(mm) Screen size(inch) Pixel pitch(mm) Color configuration Overall dimension(mm) Weight(g) 170.4(H) 8.4(Diagonal) 0.213(H) 0.213(V) R. G. B. Vertical stripe 203.0(W) 142.5(H) 5.7(D) Note 1 230 10 Note 1: Refer to Fig. 1. DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE : 3/14 B. Electrical specifications 1.Pin assignment (1).Input signal interface Pin no 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Symbol VCC VCC GND GND RxIN0RxIN0+ GND RxIN1RxIN1+ GND RxIN2RxIN2+ GND CKINCKIN+ GND NC NC GND GND Ground No Connection No Connection Ground Ground Ground LVDS receiver signal clock Ground LVDS receiver signal channel 2 Ground LVDS receiver signal channel 1 Function +3.3 V power supply +3.3 V power supply Ground Ground LVDS receiver signal channel 0 Etc. CN1 (20P) connector: HRS DF 19K-20P-1H or Compatible DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE (2) LVDS transmitter/receiver signal mapping Symbol TxIN0 TxIN1 TxIN2 TxIN3 TxIN4 TxIN5 TxIN6 TxIN7 TxIN8 TxIN9 TxIN10 TxIN11 TxIN12 TxIN13 TxIN14 TxIN15 TxIN16 TxIN17 TxIN18 TxIN19 TxIN20 TxCLKIN R0 R1 R2 R3 R4 R5 G0 G1 G2 G3 G4 G5 B0 B1 B2 B3 B4 B5 Hs Vs DE CLK Red data (LSB) Red data Red data Red data Red data Red data (MSB) Green data (LSB) Green data Green data Green data Green data Green data (MSB) Blue data (LSB) Blue data Blue data Blue data Blue data Blue data (MSB) Horizontal sync Vertical sync Data enable Clock Function : 4/14 6 bit red display data 6 bit green display data 6 bits blue display data Dot clock 2. Absolute maximum ratings Parameter Power voltage Input signal voltage Operating temperature Storage temperature Symbol VCC VLH Top TST Min. -0.3 -0.3 0 -20 Values Max. 4 VCC+0.3 +60 (GND = 0 V) Unit VDC VDC Remark At 25 At 25 Note 1 Note 1 +70 Note 1:The relative humidity must not exceed 90% non-condensing at temperatures of 40 or less. At temperatures greater than 40 , the wet bulb temperature must not exceed 39 . When operate at low temperatures, the brightness of CCFL will drop and the lifetime of CCFL will be reduced. Note 2:The unit should not be exposed to corrosive chemicals. DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE 3. Electrical characteristics a. Typical operating conditions Item Power supply voltage Input voltage Current consumption Inrush current Internal logic Low voltage High voltage Power ripple voltage Symbol VCC IA IB I RUSH VIL VIH VRP 0 0.7VCC Min. 3.0 Typ. 3.3 310 330 1500 0.3 VCC VCC 100 Max. 3.6 : 5/14 Unit V mArms mArms mApeak Remark Note 1 Note 2 mVp-p Note 1:Effective value (mArms) at VCC = 3.3 V/25| . IA IB Black (0) 64 Gray (7) 64 Vertical stripe line White 64 Grayscale Black Note 2: Refer to the following power-on condition. 90% Vcc 10% Ton=470 s Sequence of Power-on/off and signal-on/off T3 T4 T2 0 (c) T1 T5 T2 70msec (c) 300msec (c) Input signal 300msec (c) T5 10msec Apply the lamp voltage within the LCD operating range. When the backlight turns on before the LCD operation or the LCD turns off before the backlight turns off, the display may momentarily become abnormal. DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com Power 30ms T1 70msec T3 T4 PAGE Caution : 6/14 The above on/off sequence should be applied to avoid abnormal function in the display. In case of handling: Make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector. b. Display color vs. input data signals Display colors Black Blue Red Magenta Green Cyan Yellow White Black Dark Data signal (0 : Low level, 1: High level) R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 1 0 0 1 1 0 0 1 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 Basic colors Red grayscale bright 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red Black Dark Green grayscale bright 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 1 1 1 0 0 0 0 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 Green Black Dark Blue grayscale bright 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 0 1 Blue DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com Note: Each basic color can be displayed in 64 gray scales using the 6 bit data signals. By combining the 18-bit data signals(R, G, B), the 262, 144 colors can be achieved on the display. PAGE c. Input signal timing Timing diagrams of input signal are shown in Fig 2. (1). Timing characteristics of input signals DE mode Item Clock frequency Horizontal blanking Vertical blanking Symbol Fck Thb1 Tvb1 Min. 38 235 10 Typ. 40 256 28 Max. 42 500 150 : 7/14 Unit MHz Clk Th Remark (2). The timing condition of LVDS Item The differential level The common mode input voltage The input setup time The input hold time Symbol Min. 0.1 VID 2 0.5 0.5 Typ. Max. 0.6 2.4 VID 2 Unit V V ns ns VID VIC tsu1 th1 VID VID = VIAP - VIAM VIAP VIAM tsu1 th1 An 7 LCK d. Display position D( 1,1 ) D( 1,2 ) . . . D( 1,Y ) . . . D( 1,599 ) D( 1,600 ) D( 2,1 ) D( 2,2 ) ...... ...... ...... D( 2,Y ) ...... ...... D( 2,599 ) D( 2,600 ) ...... ...... D( X,1 ) D( X,2 ) . . . D( X,Y ) . . . D( X,599 ) D( X,600 ) ...... ...... ...... ...... ...... ...... ...... D( 799,1 ) D( 799,2 ) . . . D( 799,Y ) . . . D( 800,1 ) D( 800,2 ) . . . D( 800,Y ) . . . D( 799,599) D( 800,599 ) D( 799,600) D( 800,600) DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE e. Backlight driving conditions Parameter Lamp voltage Lamp current Power consumption Lamp starting voltage Frequency Lamp life time Symbol VL IL PL VS FL LL 10000 Min. Typ. (505) 4.6 (2.3) 750 550 60 20000 Max. - : 8/14 Unit Vrms mArms W Vrms KHZ Hr Remark Note 1 Note 1 Note 2 T=0 T=25 Note 3 Note 1, 4 Note 1: T= 25 Note 2: Inverter should be designed with the characteristic of lamp. When you are designing the inverter, the output voltage of the inverter should comply with the following conditions. (1). The area under the positive and negative cycles of the waveform of the lamp current and lamp voltage should be area symmetric(the symmetric ratio should be larger than 90%). (2). There should not be any spikes in the waveform. (3). The waveform should be sine wave as possible. (4). Lamp current should not exceed the maximum value within the operating temperature (It is prohibited to over the maximum lamp current even if operated in the non-guaranteed temperature). When lamp current over the maximum value for a long time, it may cause fire. Therefore, it is recommend that the inverter should have the current limit circuit. Note 3: Lamp frequency may produce interference with horizontal synchronous frequency and this may cause line flow on the display. Therefore lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference. In case using the inverter by PWM control, PWM frequency may interference with frame frequency. We suggest that PWM frequency is same as frame frequency. Note 4: Brightness to be decrease to the 50% of the initial value. Note 5: CN2 connector (backlight): BHSR-02VS-1(JST) Mating connector: SM02B-BHSS-1-TB (JST) Pin no. 1 2 Symbol H L Function CCFL power supply(H.V.) CCFL power supply(GND) Remark Cable color: Pink Cable color: White DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE : 9/14 C. Optical specifications ( Note 1, Note 2, Note 3 ) Item Response time Rising time Falling time Contrast ratio Viewing angle Top Bottom Left Right Brightness Color chromaticity(CIE) CR Symbol Condition Specification Min. 150 30 10 40 40 Typ. 20 30 200 150 0.310 0.330 Max. 40 50 1.8 Unit Remark Wx Rx Ry Gx Gy Bx By Wy White uniformity W Note 1: Ambient temperature = 25 . Note 2: To be measured in dark room after backlight warm up 30 minutes. Note 3: To be measured with a viewing cone of 1 by Topcon luminance meter BM-5A. Note 4: Definition of response time: The output signals of photodetector are measured when the input signals are changed from "Black" to "White" (falling time) and from "White" to "Black" (rising time), respectively. The response time interval between the 10% and 90% of amplitudes. Refer to figure as below. "White" 100% 90% Signal(Relative value) 10% 0% Tr DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS PAPER SHALL NOT BE REPRODUCED, COPIED, OR YL CR Tr Tf =0 =0 ms Note 4 Note 5 10 deg. Note 8 =0 =0 nit Note 6,7 Note 9 "Black" "White" Tf PAGE Note 5. Definition of contrast ratio: Contrast ratio is calculated with the following formula. Contrast ratio (CR)= : 10/14 Photodetector output when LCD is at "White" state Photodetector output when LCD is at "Black" state Note 6: Definition of brightness: This shall be measured at center of the screen. Note 7: Driving conditions for CCFL : IL=(4.6) mA,60KHz Frequency Note 8: Definition of viewing angle: Note 9: Definition of white uniformity: White uniformity is defined as the following with thirteen measurements (1~9). Maximum Luminance of nine points W = Minimum Luminance of nine points DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE : 11/14 D. Reliability test items (Note 1) Test tem High temperature storage Test Condition 70 , 240Hrs Remark Note 1, 2, 3 Low temperature storage -20 , 240Hrs Note 1, 2, 3 High temperature & high humidity operation 40 , 90%RH, 240Hrs (No condensation) Note 1, 2, 3 High temperature operation 60 , 240Hrs Note 1, 2, 3 Low temperature operation 0 , 240Hrs Note 1, 2, 3 Temperature cycling (non-operation) Electrostatic discharge (non-operation) Vibration (non-operation) Mechanical shock (non-operation) -20 ~70 1H, 10mins, 1H, 5cycles Note 1, 2, 3 150 pF,150 ,10kV,1 second, 9 position Note 3 on the panel, 10 times each place Sweep:1G, 10HZ ~ 500HZ ~ 10HZ /2.5min Note 1, 2, 3 2 hour for each direction X, Y, Z (6 Hrs in total) 50G/11ms, 200G/2ms, once for each direction X, Y, Z Note 1, 2, 3 Note 1: Evaluation should be tested after storage at room temperature for one hour. Note 2: There should be no change which might affect the practical display function when the display quality test is conducted under normal operating condition. Note 3: Judgement : 1.Function OK. 2.No serious image quality degradation . E. Display quality The display quality of the color TFT-LCD module should be in compliance with the Unipac's OQC inspection standard. F. Handling precaution The Handling of the TFT-LCD should be in compliance with the Unipac's handling principle standard. DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE : 12/14 G. Packing form : LCD Module Anti-Static Bag TAPE NOTE : 1. Max. Capacity : 30 LCD Modules/Carton. 2. Max. Weight : 10 Kg/Carton. 3. Meas : 600 mm*353mm*210mm. EPP Cushion Carton DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com PAGE : 13/14 DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com Fig.1 LCM outline dimensions Vs Tvw Th Tve Invalid X,1 X,2 X,3 X,599 X,600 Invalid Tv Hs Tvf Tvbl Thb Tvd Tvf RGB Thw X,599 X,600 DE Hs Th CLK The invalid 1,Y 2,Y 3,Y 799,Y 800,Y Thf Thf invalid RGB Thbl Thd 800,Y DE (1 pixel / clock) RGB,DE,Hs CLK VIH VIL VIH VIL Vs VIH VIL Hs Tvpd VIH VIL Tds,Tes,Ths Tdh,Teh,Thh PAGE Tch Tcl : 14/14 DATA MODUL INC. - 1767-46 Veterans Memorial Highway - Islandia NY 11749 - Tel. 631-951-0800 - Fax 631-951-2121 - www.datamodul.com Fig.2 Timing chart |
Price & Availability of UB084S01V1
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |