![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
1500W Single Output Power Supply Features : S P V- 1 5 0 0 Universal AC input/Full range ZVS new technology AC input active surge current limiting Built-in active PFC function,PF>0.95 series Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC ball bearing fan High power density 8.3W/inch3 Current sharing up to 4500W(2+1) Alarm signal output Built-in 12V/0.1A auxiliary output for remote control Built-in remote ON-OFF control Built-in remote sense function 3 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE AUXILIARY POWER(AUX) FUNCTION REMOTE ON/OFF CONTROL ALARM SIGNAL OUTPUT OUTPUT VOLTAGE TRIM WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Note.5 SPV-1500-12 12V 125A 0 ~ 125A 1500W SPV-1500-24 24V 63A 0 ~ 63A 1512W 150mVp-p SPV-1500-48 48V 32A 0 ~ 32A 1536W 200mVp-p RIPPLE & NOISE (max.) Note.2 150mVp-p 1.0% 0.5% 0.5% 1500ms, 100ms at full load 10ms at full load 90 ~ 264VAC 47 ~ 63Hz 0.95/230VAC 86.5% 17A/115VAC 30A/115VAC <2.0mA / 240VAC 105 ~135% rated output power 13.8 ~ 16.8V 8A/230VAC 60A/230VAC 0.98/115VAC at full load 127 ~ 370VDC 5% typical adjustment by VR, 20% ~ 120% adjustmen by 1~6VDC external control 14ms at full load 16ms at full load 90% 90% Protection type : Constant current limiting, recovers automatically after fault condition is removed 30 ~ 34.8V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover 105 5 (TSW2 ) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 12V@0.1A(Only for Remote ON/OFF control) Please see the Function Manual Please see the Function Manual 2.4 ~ 13.2V -20 ~ +70 -40 ~ +85 4.8 ~ 28V (Refer to output load derating curve) , 10 ~ 95% RH 9.6 ~ 56V 20~90% RH non-condensing 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 109K hrs min. MIL-HDBK-217F (25 ) 278*127*83.5mm (L*W*H) 2.6Kg; 6pcs/16.6Kg/1.54CUFT OTHERS NOTE DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:SPV-1500-SPEC 2009-06-08 1500W Single Output Power Supply Mechanical Specification 240 S P V- 1 5 0 0 Case No.943A 11.2 16 max. series Unit:mm 22.7 83.5 38.1 38 8-M4 L=5(Both Sides) 278 240 11.2 OUTPUT 17.5 4 +V -V CN1 CN2 CN3 86 42 86 42 64 2 75 31 75 31 53 1 4-M4 L=5 127 93 Air flow direction I/P 16 LED 2 3 AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Assignment FG AC/N AC/L Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent Pin No. 1 2 3 4 Assignment RCG RC2 PV PS Pin No. 5,7 6 8 Terminal Assignment Mating Housing -S LS(Current Share) HRS DF11-8DS HRS DF11-**SC or equivalent or equivalent +S RCG: Remote ON/OFF Ground -S: -Remote Sensing RC2: Remote ON/OFF LS: Load Share PV: Output voltage external control +S: +Remote Sensing PS: Reference voltage terminal, PS and PV are connected when shipping Control Pin No. Assignment(CN3) : HRS DF11-6DP-2DS or equivalent Pin No. 1 2 3 Assignment P OK GND P OK RCG Pin No. 4 5 6 Terminal Assignment Mating Housing AUXG HRS DF11-6DS HRS DF11-**SC RC1 or equivalent or equivalent AUX AUXG: Auxiliary Ground RC1: Remote ON/OFF AUX: Auxiliary Output P OK GND: Power OK Ground P OK: Power OK Signal RCG: Remote ON/OFF Ground 13 10 1 SVR Block Diagram EMI FILTER ACTIVE INRUSH CURRENT LIMITING PFC fosc : 70KHz PWM fosc : 100KHz +S I/P RECTIFIERS & PFC PFC CONTROL O.T.P. POWER SWITCHING RECTIFIERS & FILTER +V -V -S O.V.P. O.L.P. PWM CONTROL LOAD SHARING DETECTION CIRCUIT REMOTE CONTROL FAN P OK RC LS RECTIFIERS & FILTER AUX POWER (12V/0.1A) AUX POWER File Name:SPV-1500-SPEC 2009-06-08 1500W Single Output Power Supply Derating Curve S P V- 1 5 0 0 Static Characteristics Ta=25 series 100 Others 80 100 90 60 LOAD (%) LOAD (%) 60 70 (HORIZONTAL) 50 40 12V 80 70 60 20 -20 0 10 20 30 40 45 50 90 100 120 140 150 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz Function Manual 1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Fig. 1.2(A) Connection Method Output on SW Open SW Logic Output off SW Close Fig. 1.2(B) SW Open SW Close Fig. 1.2(C) SW Close SW Open Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source (B)Using internal 12V auxiliary output AUX 2.2K RC1 150 12V typ. 5V RC2 620 RCG AUXG SW 12V typ. 150 2.2K AUX RC1 RC2 RCG SW AUXG (C)Using internal 12V auxiliary output AUX 2.2K 150 12V typ. RC1 RC2 SW RCG AUXG File Name:SPV-1500-SPEC 2009-06-08 1500W Single Output Power Supply S P V- 1 5 0 0 P OK series 2.Alarm Signal Output (1)Alarm signal is sent out through "P OK" & "P OK GND" pins (2)An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 10mA (3)Table 2.1 explains the alarm function built-in the power supply Function Description Output of alarm(P OK) The signal is "Low" when the power supply is above Low 15% of the rated output voltage-Power OK (0.5V max at 10mA) P OK High or open The signal turns to be "High" when the power supply (External applied voltage is under 15% of the rated output voltage-Power Fail 10mA max.) Table 2.1 Explanation of alarm function R 0.1uF 100K V P OK GND External voltage and R (The max. sink is 10mA and 50V) Fig. 2.2 Internal circuit of P OK (Open collector method) 3.External Voltage Control Vout 120 OVP 120%(Typ.) +S +V -V -S PV 1~6V -S PS +V OUTPUT VOLTAGE (%) 100 80 60 40 20 V 100 OUTPUT CURRENT (%) -V LOAD Non-Linear 80 60 40 20 V 1 2 3 4 5 6 20 40 60 80 100 120 EXTERNAL VOLTAGE (DC) OUTPUT VOLTAGE (%) Note: Reference voltage terminal, PS and PV are connected when shipping 4.Current Sharing (1)Parallel operation is available by connecting the units shown as below (+S,-S and LS are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9 (4) In parallel operation 3 units is the maximum, please consult the manufacturer for other applications (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit Note : In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output LEDs will not turn on. No.1(Master) +S -S CN1 LS V+ V+S -S CN2 LS AC/L AC/N No.2(Slave) +S -S CN1 LS V+ V+S -S CN2 LS AC/L AC/N +S No.3(Slave) +S -S CN1 LS +V -V Load V+ -S V+S -S CN2 LS AC/L AC/N File Name:SPV-1500-SPEC 2009-08-18 |
Price & Availability of SPV-1500-12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |