If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
85 Series Miniature Plug-in Timers 5 - 10 A * Six time scales, from 0.1s to 10h * Each timer has 2 functions * Supply voltage: 12, 24, 48, 110/125 V AC/DC (non polarized); 230/240 V AC * Functions and time scales set by DIP switches situati sulla parte superiore del rele * LED indication * 2 CO (DPDT), 3 CO (3PDT) 10 A 250 V AC1 or 4 CO (4PDT) 5 A 252 V AC1 contacts available * Sockets and accessories: see 94 series * Conforms to EN 61812-1 standard * Approvals (according to type): CSA, cULus INDUSTRIAL APPLIANCES INDUSTRIAL AUTOMATION 11 85 Series Miniature Plug-in Timers 5 - 10 A 85.32 (R) (R) 85.54 C US C US MINIATURE PLUG-IN TIMERS 5 - 10 A TYPE 85.32 2 CO (DPDT) 10 A TYPE 85.33 3 CO (3PDT) 10 A TYPE 85.34 4 CO (4PDT) 5 A - Functions available, see page 13: ON delay (AI) ON pulse (DI) - 2.0 x 0.5 mm terminals - LED indication: red = relay ON green = power ON - Mounting: see 94 series sockets - Ordering information: see page 15 MINIATURE PLUG-IN TIMERS 5 - 10 A TYPE 85.52 2 CO (DPDT) 10 A TYPE 85.53 3 CO (3PDT) 10 A TYPE 85.54 4 CO (4PDT) 5 A - Functions available, see page 13: symmetrical recycler: pulse start (SW) symmetrical recycler: pause start (SP) - 2.0 x 0.5 mm terminals - LED indication: red = relay ON green = power ON - Mounting: see 94 series sockets - Ordering information: see page 15 27.7 3.6 20.6 20.6 20.6 14.5 1.9 4.1 6.3 6.7 6.1 59.1 3.7 13.2 3.7 3.7 6.6 3.7 3.7 4.4 3.7 1 54 8 1 42 5 3 6 1 52 6 3 74 8 9 13 12 14 7 13 8 9 14 9 13 10 11 14 12 U U U 85.32 / 85.52 12 85.33 / 85.53 85.34 / 85.54 7.2 58 85 Series Miniature Plug-in Timers 5 - 10 A EMC SPECIFICATIONS TYPE OF TEST ELECTROSTATIC DISCHARGE - contact discharge - air discharge RADIO-FREQUENCY ELECTROMAGNETIC FIELD (80 / 1000 MHz) FAST TRANSIENTS (burst) (5-50 ns, 5 kHz) on Supply terminals SURGES (1.2/50 s) on Supply terminals - common mode - differential mode RADIO-FREQUENCY COMMON MODE (0.15 / 80 MHz) on Supply terminals POWER-FREQUENCY (50 Hz) RADIATED AND CONDUCTED EMISSION ENV 50141 (IEC 1000-4-6) EN 61000-4-8 EN 55022 EN 61000-4-5 4 kV 2 kV 10 V 30 A/m class B ENV 50140 (IEC 1000-4-3) EN 61000-4-4 REFERENCE STANDARD EN 61000-4-2 n.a. 8 kV 15 V/m 4 kV DESCRIPTION OF THE FUNCTIONS The (C) indicated in the diagrams refers to the position of the NO contacts. When the red LED (C) is illuminated the NO contact are closed. U = SUPPLY VOLTAGE Types 85.32 85.33 85.34 U C C = RELAY CONTACT (NO) (AI) ON delay. Apply power to timer. Contact transfers after preset time has elapsed. Reset occurs when power is removed. (DI) ON pulse. Apply power to timer. Contact transfers immediately. After preset time has elapsed, contact returns to original position. (SW) Symmetrical recycler: pulse start. Apply power to timer. First transfer of contact occurs as soon as power is applied. The timer now cycles between ON and OFF as long as power is applied. The ratio is 1:1 (time off = time on). (SP) Symmetrical recycler: pause start. Apply power to timer. First transfer of contact occurs after preset time has elapsed. The timer now cycles between OFF and ON as long as power (time off = time on). 1234 U T t Types 85.52 85.53 85.54 C T U C t U C T T T T t T T T T T t (0.1...1) s (1...10) s (10...60) s (1...10) min (10...60) min (1...10) h 123 123 123 123 123 123 13 85 Series Miniature Plug-in Timers 5 - 10 A TECHNICAL DATA SUPPLY VOLTAGE (UN) OPERATING RANGE POWER CONSUMPTION DIELECTRIC STRENGTH between coil and contacts: between open contacts: between adjacent contacts: between frame and live parts: MECHANICAL LIFE PROTECTION CATEGORY DELAY SETTING REPEATABILITY SETTING ACCURACY - FULL RANGE RECOVERY TIME AMBIENT TEMPERATURE POWER LOST IN THE ENVIRONMENT - without load: - at full load: 12, 24, 48, 110/125 V AC/DC (non polarized) 230/240 V AC AC (50/60 Hz)/DC: (0.85...1.1)UN AC: 2 VA DC: 2 W 2 (DPDT) - 3 CO (3PDT) 2,000 V 1,000 V 2,000 V 1,500 V 10 * 106 cycles IP 40 0.1 s...10h (see time scales) 2% 5% 20 ms (-20...+60)C 85.x2.8.230 0.6 W 3.7 W 85.x3.8.230 0.6 W 4.7 W 85.x4.8.230 0.6 W 3.3 W 4 CO (4PDT) 2,000 V 1,000 V 1,550 V 1,500 V WORKING CONDITIONS: in conformity with EC Directive on EMC (89/336), the timer has a high level of immunity, both from radiated and conducted disturbances (according to EN 61812-1). However, the timer (and its supply and control wiring) must be installed as far as possible from disturbance sources (such as transformers contactors, circuit-breakers and their power cables). CONTACT SPECIFICATIONS 2 CO (DPDT) RATED CURRENT MAXIMUM PEAK CURRENT RATED VOLTAGE MAXIMUM SWITCHING VOLTAGE NOMINAL RATE IN AC1 NOMINAL RATE IN AC15 (230 V) BREAKING CAPACITY IN DC1 SINGLE PHASE MOTOR RATING (230 V AC) ELECTRICAL LIFE IN AC1 CONTACT RESISTANCE: initial CONTACT MATERIAL 10 A 20 A 250 V AC 400 V AC 2,500 VA 500 VA see diagram H 85 0.37 kW/0.6 HP see diagram F 85/2 50 m AgNi 3 CO (3PDT) 10 A 20 A 250 V AC 400 V AC 2,500 VA 500 VA see diagram H 85 0.37 kW/0.6 HP see diagram F 85/2 50 m AgNi 4 CO (4PDT) 5A 10 A 250 V AC 400 V AC 1,250 VA 250 VA see diagram H 85 0.125 kW/0.2 HP see F 85/1 50 m AgNi 14 85 Series Miniature Plug-in Timers 5 - 10 A F 85/1 10 7 107 F 85/2 CYCLES 106 CYCLES 0 0.5 1.0 1.5 2 10 6 105 10 5 0 1 2 3 4 LOAD (kVA) DC contact life vs AC1 load. 4 CO types (5 A) LOAD (kVA) Contact life vs AC1 load. 2 - 3 CO types (10 A) H 85 20 MAX SWITCHING CURRENT (A) 10 6 4 2 1 0.6 0.4 0.2 0.1 A B C D 1 20 60 100 140 180 220 VOLTAGE DC (V) Breaking capacity for DC1 load. 1 = 4 CO type A = load applied to 1 contact B = load applied to 2 contacts in series C = load applied to 3 contacts in series D = load applied to 4 contacts in series ORDERING INFORMATION Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage with AI - DI functions. 85 Series 3 4 No. of poles 2 = 2 CO (DPDT) - 10A 3 = 3 CO (3PDT) - 10A 4 = 4 CO (4PDT) - 5A 0 024 0 0 0 0 Type 3 = Functions: AI - DI 5 = Functions: SW - SP Coil version 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) for 230 V only Coil voltage 012 = 12 V AC/DC 024 = 24 V AC/DC 048 = 48 V AC/DC 110 = 110/125 V AC/DC 230 = 230/240 V AC 15 94 Series - Sockets and Accessories for 85 Series Timers A range of sockets and accessories for 85 series timers Features include: * PCB, screw terminal, panel or 35 mm rail (EN 50022) mount versions * Flammability in conformity with UL 94 * Approvals (according to type): BBJ, CSA, DEMKO, CS - IMQ, SEV, cULus 16 94 Series - Sockets and Accessories for 85 Series Timers 94.14 94.22 P.C.B. SOCKETS TYPE 94.12 for types 85.32 - 85.52 TYPE 94.13 for types 85.33 - 85.53 TYPE 94.14 for types 85.34 - 85.54 CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: self-extinguishing PPEm (V1) - CONNECTIONS: Cu Sn 6 tin plated PANEL MOUNT SOLDER SOCKETS (1 mm thick panel mount) TYPE 94.22 for types 85.32 - 85.52 TYPE 94.23 for types 85.33 - 85.53 TYPE 94.24 for types 85.34 - 85.54 CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: polycarbonate (PC) - CONNECTIONS: Cu Sn 6 silver plated 21.5 21.5 21.5 5 11.5 21.5 21.5 21.5 5 11.5 29.5 29.5 29.5 25.5 29.5 29.5 94.12 = 13.2 = 5.3 4.1 29.5 29.5 1.5 94.13 = 6.6 = 94.14 = 5.3 4.1 4.4 13.5 29.5 25.5 94.22 94.23 94.24 14.5 = 5.3 4.1 1 1.5 29.5 1.5 6.3 7.5 = 21.5 = 6.3 7.5 = 21.5 = 6.3 7.5 = 21.5 = 21.8 6.5 6.5 94.12 94.13 6.5 94.14 25.8 17 94 Series - Sockets and Accessories for 85 Series Timers 94.34 94.64 PANEL MOUNT SOLDER SOCKETS (M3 screw mount) TYPE 94.32 for types 85.32 - 85.52 TYPE 94.33 for types 85.33 - 85.53 TYPE 94.34 for types 85.34 - 85.54 CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: self-extinguishing PPEm (V1) - CONNECTIONS: Cu Sn 6 tin plated CLAMP TERMINALS SOCKETS (panel or 35 mm rail - EN 50022- mount) TYPE 94.62 for types 85.32 - 85.52 TYPE 94.64 for types 85.34 - 85.54 Accessories: TYPE 094.81 retaining clip CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: self-extinguishing PPEm (V1) - CONNECTIONS: Cu Zn 33 nickel plated - PROTECTION CATEGORY: IP 20 - Non removable pozidrive slotted terminal screws. - Identification label. 21.5 21.5 21.5 16.5 13.5 26 22.5 26 22.5 20.5 33 = 40.5 40.5 40.5 66.5 3.1 66.5 94.32 94.33 7.5 3.2 94.34 = 3.1 = = 17.5 44 8 14 5 12 1 NO NC 44 8 42 4 34 7 32 3 24 6 22 2 14 5 12 1 = NO NC 26.5 34 = 42 4 7.5 22.5 A2 14 A1 13 COIL A2 14 41 12 31 11 21 10 A1 13 11 9 COIL 41 12 11 9 COM COM 94.62 94.64 18 94 Series - Sockets and Accessories for 85 Series Timers 94.74 94.82 SCREW TERMINALS SOCKETS (panel or 35 mm rail - EN 50022- mount) TYPE 94.73 for types 85.32 - 85.52 TYPE 94.74 for types 85.34 - 85.54 Accessories: TYPE 094.81 retaining clip CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: self-extinguishing PPEm (V1) - CONNECTIONS: Cu Zn 33 nickel plated - PROTECTION CATEGORY: IP 20 - Non removable pozidrive slotted terminal screws. - Identification label. SCREW TERMINALS SOCKETS (panel or 35 mm rail - EN 50022- mount) TYPE 94.82 for types 85.32 - 85.52 Accessories: TYPE 094.81 retaining clip CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: self-extinguishing PPEm (V1) - CONNECTIONS: Cu Zn 33 nickel plated - PROTECTION CATEGORY: IP 20 - Non removable pozidrive slotted terminal screws. - Identification label. 23 29.5 34.2 70.5 68 4.1 O 4.2 24 30 34 6 24 5 14 4 23 26 3 36.3 24 30 44 8 34 7 24 6 14 5 27 26 NO 42 4 12 1 NO NC 71.3 NC 32 3 22 2 12 1 42 4 32 3 22 2 12 1 NC 44 8 14 5 NO A2 A1 COIL COM A2 14 A1 13 COIL 41 12 11 9 31 9 21 8 11 7 41 12 31 11 21 10 11 9 COM COM 94.73 94.74 A2 14 A1 13 COIL 19 94 Series - Sockets and Accessories for 85 Series Timers 94.04 094.06 CLAMP TERMINALS SOCKETS (panel or 35 mm rail - EN 50022- mount) TYPE 94.02 for types 85.32 - 85.52 TYPE 94.04 for types 85.34 - 85.54 Accessories: TYPE 094.81 retaining clip Accessories: TYPE 094.06 6-way jumper link CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: 103 M - DIELECTRIC STRENGTH: 2 kV AC - MATERIAL: self-extinguishing PA 6 20% FV (V1) - CONNECTIONS: Cu Zn 33 nickel plated - PROTECTION CATEGORY: IP 20 - Non removable pozidrive slotted terminal screws. - Identification label. 61 27 27 26 17.5 17.5 6-WAY JUMPER LINK TYPE 094.06 for socket 94.02 and 94.04 CHARACTERISTICS - LOAD: 10 A 250 V 135 3.3 5.1 7 0.75 26.25 27 27 27 26.25 76 32 41 12 11 9 COM 41 12 31 11 21 10 11 9 COM 35.5 44 8 14 5 NO NC 44 8 34 7 24 6 14 5 NO NC 42 4 12 1 42 4 32 3 22 2 12 1 A2 14 A1 13 COIL A2 14 A1 13 COIL 94.02 20 94.04 10.3 |
Price & Availability of 8534-8230
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |