small relay d2 neutral product information d2 titel_ok 22.09.1999 12:12 uhr seite 2
2 siemens electromechanical components small relay d2 neutral v23105 pcb relay for dc operation, neutral, monostable features o all purpose relay with 2 changeover contacts, suitable for a wide range of applications o four different coil versions available (150, 200, 400, 500 mw) o the switching capacity ranges from low signal up to 3 a o standard pinning o high-voltage resistance according to fcc part 68: 1.5 kv (10/160 m s) typical applications o communications technology o telecommunications terminal and accessories o entertainment electronics o measurement and control equipment version C monostable, 1 winding C with 2 changeover contacts C for printed circuits assembling C plastic case C immersion cleanable approvals ul file e 48393 csa file lr 45064-27 british telecom bt47w spec. t4563c dimension drawing (in mm) mounting hole layout view on the terminals basic grid 2.54 mm according to en 60097 and din 40803 terminal assignment view on the terminals approx. 1.5 x original size ecr1029-r ecr1541-6
siemens electromechanical components 3 small relay d2 neutral load limit curve i = switching current u = switching voltage = recommended application field load limit curve: quenching of the arc during the transit time contact data number of contacts and type 2 changeover contacts contact assembly single contacts contact material silver nickel, gold-plated, against silver nickel, gold-plated max. continous current at max. ambient temperature 3 a maximum switching current 3 a maximum switching voltage 250 vdc 230 vac maximum switching capacity dc voltage ac voltage 60 w, see load limit curve 120 va recommended for load voltages greater than 10 mv thermoelectrical potential < 15 m v contact resistance (initial value) / measuring current / driver voltage 100 m w / 10 ma / 20 mv ecr2265-5 60 w 30 w 10 0.1 20 0.2 0.3 0.4 0.5 0.6 3 1 0.8 1.5 2 45 u [vdc] i [a] 30 40 50 60 80 100 150 250 200 300
4 siemens electromechanical components small relay d2 neutral *) < 80% of the nominal voltage on request coil data nominal voltages from 3 vdc to 48 vdc nominal power consumption of the various coil versions 150 mw 200 mw 400 mw 500 mw maximum operating voltage 150 mw 200/400/500 mw 80% of the nominal voltage *) 70% of the nominal voltage minimum release voltage 5% of the nominal voltage u i = minimum voltage at 20 c with after pre-energizing with nominal voltage without contact current u ii = maximum continuous voltage at 20 c the operating voltage limits u i and u ii are dependent on the tempe- rature according to the formulae: u i tamb = k i u i 20 c and u ii tamb =k ii u ii 20 c t amb = ambient temperature u i tamb = minimum voltage at ambient temperature t amb u ii tamb = maximum voltage at ambient temperature t amb k i a. k ii = factors (dependent on temperature), see diagram ambient temperature [c] t amb -20 -30 20 10 0 -10 0.5 0.4 30 40 50 60 70 80 85 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 k -factor ecr2266-d
siemens electromechanical components 5 small relay d2 neutral coil versions nominal voltage u nom operating voltage range at 20 c resistance at 20 c coil number ordering code block 2 vdc minimum voltage u i vdc maximum voltage u ii vdc w 150 mw nominal power consumption 3 2.4 10.2 60 6 008 5 4.0 13.0 167 16.7 001 6 4.8 15.6 240 24 002 9 7.2 23.4 540 54 006 12 9.6 31.2 960 96 003 24 19.2 59.5 3480 348 005 200 mw nominal power consumption 3 2.1 6.7 45 4.5 308 5 3.5 11.2 125 12.5 301 6 4.2 13.5 180 18 302 9 6.3 20.3 405 40.5 306 12 8.4 27.0 720 72 303 24 16.8 54.1 2880 288 305 48 33.6 108.3 11520 1152 307 400 mw nominal power consumption 5 3.5 7.9 62 6.2 401 6 4.2 9.5 90 9 402 9 6.3 14.3 203 20.3 406 12 8.4 19.1 360 36 403 24 16.8 38.3 1440 144 405 48 33.6 76.6 5760 576 407 500 mw nominal power consumption 5 3.5 6.3 36 3.6 501 6 4.2 8.9 70 7 502 9 6.3 12.5 140 14 506 10 7.0 15.0 200 20 504 12 8.4 17.8 280 28 503 24 16.8 34.4 1050 105 505 48 33.6 67.3 4000 400 507 coil versions, bt 47 type / specification t4563c (current tested) nominal voltage u nom vdc operating current ma resistance at 20 c w british telecom code coil number ordering code block 2 5 80.0 36 3.6 47w/5 475 10 32.5 200 20 47w/9 479 12 27.0 280 28 47w/6 476 24 14.0 1050 105 47w/7 477 48 7.0 4000 400 47w/8 478
6 siemens electromechanical components small relay d2 neutral general data operate time at u nom and 20 c, typ. 5 ms release time at u nom without parallel diode, typ. 4 ms bounce time, typ. 3 ms maximum switching rate without load 20 operations/s ambient temperature according to din iec 61810-1 or vde 0435 part 201 150/200 mw nominal power consumption 400 mw nominal power consumption 500 mw nominal power consumption -25 c ... +85 c -25 c ... +70 c -25 c ... +60 c thermal resistance approx. 100 k/w maximum permissible coil temperature 105 c vibration resistance, 10 to 55 hz according to iec 60068-2-6 55 to 500 hz according to iec 60068-2-6 function:10 g damage: 20 g shock resistance, half sinus, 11 ms according to iec 68068-2-27 function:10 g damage: 40 g degree of protection according to vde 0470 part 1 en 60529 / iec 60529 immersion cleanable, ip 67 capacitance at 1 khz, 100 vac between open contacts between closed contacts between contact and coil < 2 pf < 1.5 pf < 5 pf electrical endurance at resistive load 6 vdc / 100 ma 30 vdc / 1 a 30 vdc / 2 a (only 400 and 500 mw coils) 230 vac / 500 ma > 2 x 10 6 operations approx. 5 x 10 5 operations approx. 1 x 10 5 operations > 3 x 10 5 operations mechanical endurance 15 x 10 6 operations mounting position any processing information ultrasonic cleaning is not recommended weight approx. 6 g insulation insulation resistance at 500 v 3 1000 m w dielectric test voltage (1 min) contact/winding changeover contact/changeover contact at open contact 1000 vac rms / 1500 vdc 750 vac rms / 1000 vdc 750 vac rms / 1000 vdc surge voltage resistance according to fcc 68 (10/160 m s) 1500 v
siemens electromechanical components 7 small relay d2 neutral ordering code v 2 0 1 5 5 a 2 3 a 0 1 identification of the small relay d2 neutral version 0 = 150 mw nominal power consumption 3 = 200 mw 4 = 400 mw 5 = 500 mw coil number 08 = 3 v nominal voltage (only coils with 150/200 mw nominal power consumption*) 01 = 5 v nominal voltage 02 = 6 v 06 = 9 v 04 = 10 v (only coil with 500 mw nominal power consumption) 03 = 12 v 05 = 24 v 07 = 48 v (not coil with 150 mw nominal power consumption) bt 47 versions 475 = 5 v nominal voltage 479 = 10 v 476 = 12 v 477 = 24 v 478 = 48 v contact assembly / material a201 = 2 changeover contacts, silver nickel, gold-plated, against silver nickel, gold-plated *) coils with 400/500 mw nominal power consumption on request ordering example: v23105-a5301-a201 small relay d2 neutral, coil 5 v nominal voltage, 200 mw nominal power consumption, contact material silver nickel, gold-plated, against silver nickel, gold-plated
|