  zelio-time ? timers re7, re8, and re9 file 9050 contents description page re7 application data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 re7 multifunction timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 re7 on delay timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 re7 on delay and off delay timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 re7 off delay timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 re7 interval timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 re7 repeat cycle timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 re7 star-delta timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 re7 dimensions and wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20?21 re8 timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 re9 timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 catalog 04
zelio-time tm timers - re7 application data ? 1993-2004 schneider electric all rights reserved 2 06/2004 the re7 timers, with only 23 catalog numbers, covers most timing applications. these timers offer multi-range timing from 50 ms to 300 hours. they are multi-voltage. three models combine several different functions: multifunction timers. these products have a transparent cover on the front to avoid any involuntary intervention on the measurement. this cover can be sealed. re7rb mw: peak current when switched on = 1 a/30 ms. application data conforming to standards iec 61812-1, en 61812-1 product certifications ambient air temperature around the device storage -40 to 185 f (-40 to + 85 c) operation -4 to 140 f (-20 to + 60 c) permissible relative humidity range conforming to iec 60721-3-3 15 to 85% environmental class 3k3 vibration resistance conforming to iec 60068-2-6, 10 to 55 hz a = 0.35 ms shock resistance conforming to iec 60068-2-27 15 gn - 11 ms degree of protection housing ip 50 terminals ip 20 degree of pollution conforming to iec 60664-1 3 ue = 300 v overvoltage category conforming to iec 60664-1 iii ue = 300 v rated insulation voltage between contact circuit and power supply or between contact circuit and control inputs conforming to iec 250 v conforming to ul and csa 300 v test voltage for insulation tests dielectric test ul and csa 2200 vac, iec 2000 vac shock wave 4800 v voltage limits power supply circuit 0.85-1.1 uc disconnection value power supply circuit > 0.1 uc mounting position without derating in relation to the normal vertical mounting position any position connection maximum cross-section stranded wire without cable end 2 # 14 awg (2 x 2.5 mm 2 ) stranded wire with cable end 2 # 16 awg (2 x 1.5 mm 2 ) tightening torque 4.5-9.9 lb-in (0.5-1.1 n m) immunity from electromagn etic interference (emc) (application class 2 conforming to en 61812-1) electrostatic discharge conforming to iec 61000-4-2 level 3 (6 kv contact, 8 kv air) electromagnetic fields conforming to iec 61000-4-3 level 3 (10 v/m) rapid transients conforming to iec 61000-4-4 level 3 (2 kv output power, 1 kv control) shock waves conforming to iec 61000-4-5 level 3 (2 kv common mode, 1 kv differential mode) radiated and conducted emissions cispr11 group 1 class a cispr22 class a consumption consumption 24 vac 48 vac 110 vac 240 vac 24 vdc 48 vdc 110 vdc 240 vdc va w re7 11bu 0.7 1.6 1.8 8.5 0.5 1.2 ? ? re7 12bu and re7 13bu 1.2 2 2.8 12.5 0.8 1.6 ? ? re7 mw 22.53.26213.22 ? file e164353 cnn nkcr file lr 89150 guide 3211 07 gl
zelio-time tm timers - re7 application data 3 06/2004 ? 1993-2004 schneider electric all rights reserved for 0.1 a, curve 1 indicates a durability of approximately 1.5 million operating cycles. as the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles, as indicated by curve 2. for cos ? = 0.3: k = 0.6 the electrical durability therefore becomes: (1.5 x 10 6 ) operating cycles x 0.6 = 900,000 operating cycles. the product life expressed above is based on average usage and normal operating conditions. actual operating life will vary with conditions. the above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life. for information on the listed warranty offered on this product, refer to the terms and conditions of sale found in the digest. time delay specifications setting accuracy as % of the full scale value 10 % repeat accuracy 0.2 % influence of voltage in the voltage range, 0.85-1.1 un < 0.2 %/v influence of temperature < 0.07 %/k immunity to micro-breaks 3 ms minimum control pulse 20 ms (except re7rb1 mw: 1 s) reset time 50 ms output circuit specifications mechanical durability in millions of operatin g cycles 20 (10 for re7rb1 mw) current limit ith 8 a rated operational limits at 70 c 24 v 115 v 250 v conforming to iec 60947-5-1/1991 and vde 0660 ac-15 n/c contact 3 a 3 a 3 a ac-15 n/o contact 5 a 5 a 5 a dc-13 n/o contact 2 a 0.2 a 0.1 a ul and csa current ratings resistive rating 5 a nema / ul b300 inductive rating 3600 va make rating 360 va break rating 5 a carry minimum switching power 12 v/10 ma contact material silver nickel 90/10 remote control input specifications signal delivered by y1-z2, x1-z2, x2-z2 control inputs no galvanic insulation between these inputs and the power supply switching current < 1 ma maximum distance 164 ft (50 m) compatibility 3/4-wire pnp and npn telemecanique sensors or other sensors without an internal load potentiometer for connection between terminals z1-z2, z3-z2 type linear at 20 % resistance 47 20 % k ? power 0.2 w maximum distance 82 ft (25 m) per shielded cable: shielding linked to terminal z2 10 1 0.1 0.01 012345678 curve 1 ac load electrical durability of contacts on resistive load in millions of operating cycles 1 0.6 0.5 0.9 0.8 0.7 0.4 0.3 1 0.8 0.6 0.5 0.4 0.3 0.2 curve 2 reduction factor k for inductive loads (applies to values taken from the durability curve above) example: an lc1f185 contactor supplied with 115 v/50 hz for a consumption of 55 va or a current consumption equal to 0.1 a and cos ? = 0.3. dc load load limit curve 300 40 30 200 100 50 20 10 0.1 0.2 0.5 1 2 5 20 10 1 2 3 1 l/r = 20 ms 2 l/r with load protection diod e 3 resistive load re7 k + ?
zelio-time tm timers - re7 timing functions ? 1993-2004 schneider electric all rights reserved 4 06/2004 timing functions operating diagram operating principle on-delay timer supply voltage output contact spdt (c/o) timing starts when the timer is energized. when the set time delay (ta) has elapsed, the output contact closes. when the timer is de-energized, the output contact returns to its initial position. the output contact does not close if the duration of the control instruction is less than the set time delay. timing can also be started by opening of a external contact (models with remote control). off-delay timer supply voltage output contact spdt (c/o) energization of the timer or closing of the control contact (models with external control) causes the output contact to close instantaneously. timing starts when the timer is de-energized or when the control contact opens. when the set time delay (tr) has elapsed, the output contact returns to its initial position. if the energization time or closing time of the control contact is less than the minimum time specified, the timing period does not start. on and off-delay timer supply voltage output contact spdt (c/o) this function is a combination of the on and off delay functions. the timing cycle must be controlled by an external contact. symmetrical the on and off delays are equal. asymmetrical the on and off delays are adjusted by 2 different potentiometers. interval timer (pulse on energization) supply voltage output contact spdt (c/o) energization of the timer causes the output contact to close instantaneously and start the timing period. the output contact returns to its initial position when the set time delay (t) has elapsed or if the supply is cut off before the end of the timing period. timer with pulse on de-energization or on opening of a external control contact supply voltage output contacts spdt (c/o) de-energization of the timer or opening of the external control contact (depending on model) causes the output contact to close instantaneously and start the timing period. when the set time delay (t) has elapsed, the contact returns to its initial position. repeat cycle timer (flashing timer) supply voltage output contact spdt (c/o) energization of the timer starts the flashing period and causes the output timer to start the flashing cycle. when the timer is de-energized, the contact returns to its initial position. symmetrical flashing timer the timer flashes with a symmetrical on/off pattern. asymmetrical flashing timer the on and off flashing timers are adjusted by 2 different potentiometers. timers for star-delta starters supply voltage output contacts energization of the timer causes the star contactor to close instantaneously and starts the timing period. when the set time delay (t) has elapsed, the star contactor returns to its initial position and the delta contactor closes, after a breaking time sufficient for the changeover. ta tr ta tr t t t t t t3
zelio-time tm timers - re7 additional functions 5 06/2004 ? 1993-2004 schneider electric all rights reserved please consult your regional sales office. 1c/o = spdt = 2 c/o = dpdt = additional functions external control of starting : opening of an external contact connected to the timer starts the timing period. closing of this contact resets the timer. partial external control of timing: closing of an external contact connected to the timer allows the timing period to be interrupted. the time elapsed is memorized. timing restarts as soon as the contact opens. this type of control enables the totalizing function to be performed. external adjustment of the time delay : one or more external potentiometers can be used for remote adjustment of the timing period or periods. output multifunction timer see page solid state re9ta 32 1 c/o re7tl or re8ta 8 or 24 2 c/o re7tp 8 1 c/o re7tm 8 solid state re9ra 32 1 c/o re7rb11 or re8rb 12 or 24 2 c/o re7rl 12 2 c/o re7rb13 12 1 c/o re8ra 24 1 c/o re7ra and re7rm 12 2 c/o re7ma13 10 1 c/o re7ma11 10 1 c/o re7mv 10 1 c/o re7pe or re8pe 14 or 26 2 c/o re7pp 14 1 c/o re8pt 26 2 c/o re7pd 14 1 c/o re7pm 14 2 c/o re8pd 26 1 c/o re7cl or re8cl 16 or 24 2 c/o re7cp 16 1 c/o re7cv 16 1 c/o re8yg 26 2 c/o re7ya and re7yr 18 1 n/c + n/o re8ya 26 solid state re9ms 33 1 c/o re7ml 6 2 c/o re7my13mw 6 2 c/o re7my13bu 6
zelio-time tm timers - re7 multi-function timers - selection ? 1993-2004 schneider electric all rights reserved 6 06/2004 for use on other functions, please see the diagrams relating to the single function products. by external potentiometer, to be ordered separately (see page 3 for specifications). if external potentiometer is used, the internal potentiometer is automatically disconnected. except control of partial stop of time delay for re7my13bu. adjustable time delay from 0.05 s to 300 h in 10 ranges (see setting procedure on the next page). t: adjustable time delay t = t1 + t2 + t3 ta: adjustable on-delay ts: partial stop time t3: switching time = 50 ms on-delay timer re7ml, my interval timer with start on energization re7ml, my repeat cycle timer with start during the on period re7ml, my repeat cycle timer with start during the off period re7ml, my on-delay timer with start on opening of external control contact. re7ml, my interval timer with start on opening of the external control contact re7ml, my timer for star-delta starters with: double on-delay timing re7my changeover contact to star connection re7my external control for start of time delay (example on on-delay function ) re7ml, my external control for partial stop of time delay (example on pulse on energization relay ) re7ml, my re7my 6 function timer function (see diagrams above) supply voltages relay output catalog number weight lb (kg) on-delay timer off-delay timer interval timers -start on energization -start on opening of remote control contact repeat cycle timer with start during the off period. repeat cycle timer with start during the on period external control possible for: -start of time delay -partial stop of time delay -adjustment of time delay 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7ml11bu 0.33 lb (0.150 kg) 8 function timer same as 6 function timer plus timer for star-delta starting -with double on-delay timing -with changeover contact to star connection 24 vdc or vac 110-240 vac 2 c/o dpdt re7my13bu 0.33 lb (0.150 kg) 24-240 vdc or vac 2 c/o dpdt re7my13mw 0.33 lb (0.150 kg) de-energized energized open closed 15/18 (25/28) 15/16 (25/26) t supply c/o spdt 15/18 (25/28) 15/16 (25/26) t supply c/o spdt 15/18 (25/28) 15/16 (25/26) t t supply c/o spdt 15/18 (25/28) 15/16 (25/26) t t supply c/o spdt 15/18 (25/28) y1/z2 15/16 (25/26) t supply start c/o spdt 15/18 (25/28) y1/z2 15/16 (25/26) t supply start c/o spdt t t3 15/18 15/16 25/28 25/26 supply "c/o 1" "star" "delta" 1 t t3 17/18 17/28 supply "c/o 1" "c/o 2" "star" "delta" supply 15/18 15/16 c/o y1/z2 ta start spdt supply 15/18 15/16 ts c/o x1/z2 t2 t1 partial stop t3 ts t 1 1 , ,,, , 1 1 1
zelio-time tm timers - re7 multi-function timers - wiring 7 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams (1) 110-240 vac: re7ml11bu or re7my13bu, 24-240 vdc or vac: re7my13mw. (2) 42-48 vac or vdc: re7ml11bu. (3) 24 vac or vdc: re7ml11bu or re7my13bu. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. 10-position timing range selector: 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h 3. switch for converting second time delay relay to instantaneous mode (depending on model). 4. leds, depending on the model: ? green led: flashes during the time delay period (except for the first 2 timing ranges), permanently on outside the time delay period. ? yellow led 1: on when 1 st relay is energized. ? yellow led 2: on when 2 nd relay is energized. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 a1 15 b1 z1 b2 y1 x1 z2 18 16 a2 18 15 b1 a1 a2 16 a1 15 b1 25 (21) z1 y1 26 (22) 28 (24) z2 18 16 a2 18 15 b1 a1 a2 16 28 (24) 25 (21) 26 (22) a1 15 y1 25 (21) z1 x1 26 (22) 28 (24) z2 18 16 a2 18 15 a1 a2 16 28 25 26 (24) (21) (22) re7ml11bu re7my13bu re7my13mw (3) (2) (1) b1 a1 b2 a2 b1 a1 b2 a2 y1 z2 (3) (2) (1) b1 a1 b2 a2 x1 z2 (3) (2) (1) start on energization start by external control external control of partial stop z1 z2 a2 x1 or y1 or z1 z2 a2 potentiometer wiring wiring precautions no galvanic insulation between supply terminals a1, a2, b1, b2 and control inputs x1, y1, z1, z2. 1 2 4 3 5 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 on-delay timers - selection ? 1993-2004 schneider electric all rights reserved 8 06/2004 by external potentiometer, to be ordered separately (see page 3 for specifications). if external potentiometer is used, the internal potentiometer is automatically disconnected. a switch on the front face of the timer allows the second contact to be used in instantaneous mode. timing adjustable from 0.05 s to 300 h in 10 ranges (see setting procedure on the next page). on-delay timer start on energization re7tl,tm, tp external control for start of time delay re7tm external control for partial stop of time delay (for totalizing function) re7tm conversion of second contact to instantaneous mode by means of switch r2 re7tp13bu functions (see diagrams above) supply voltages relay output ca talog number weight lb (kg) on-delay timer 24 vdc or vac 110-240 vac 1 c/o spdt re7tl11bu 0.33 lb (0.150 kg) on-delay timer external control possible for: -start of time delay -partial stop of time delay -adjustment of time delay 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7tm11bu 0.33 lb (0.150 kg) on-delay timer remote control possible for: -adjustment of time delay 24 vdc or vac 42-48 vdc or vac 110-240 vac _ 2 c/o dpdt re7tp13bu 0.33 lb (0.150 kg) de-energized energized open closed t: adjustable on-delay t = t1 + t2 + t3 15/18 (25/28) 15/16 (25/26) t supply c/o spdt 15/18 15/16 (y1-z2) t supply start c/o spdt 15/18 15/16 (x1-z2) t t3 t2 t1 supply partial stop c/o spdt r2 r2 21/24 25/28 t 21/22 25/26 supply c/o spdt supply c/o spdt re7t
zelio-time tm timers - re7 on-delay timers - wiring 9 06/2004 ? 1993-2004 schneider electric all rights reserved x recommended wiring diagrams (1) 110-240 vac. (2) 42-48 vac or vdc. (3) 24 vac or vdc. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. 10-position timing range selector: 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h 3. switch for converting second time delay relay to instantaneous mode (for re7tp13bu). 4. leds, depending on the model: ? green led u/t: flashes during time delay peri od, permanently on outside the time delay period. ? yellow led r1: on when 1 st relay is energized. ? yellow led r2: on when 2 nd relay is energized. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 a1 15 b1 18 16 a2 18 15 b1 a1 a2 16 a1 15 b1 25 (21) z1 b2 28 (24) z2 18 26 (22) 16 a2 18 15 b1 b2 a1 a2 16 28 25 (21) 26 (24) (22) a1 15 b1 z1 b2 y1 x1 z2 18 16 a2 18 15 b1 b2 a1 a2 16 re7tl11bu re7tp13bu re7tm11bu (3) (2) (1) b1 a1 b2 a2 b1 a1 b2 a2 y1 z2 (3) (2) (1) b1 a1 b2 a2 x1 z2 (3) (2) (1) start on energization start by external control external control of partial stop z1 z2 a2 x1 or y1 or z1 z2 a2 potentiometer wiring wiring precautions no galvanic insulation between supply terminals a1, a2, b1, b2 and control inputs x1, y1, z1, z2. 4 1 2 3 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 on-delay and off-delay timers - selection ? 1993-2004 schneider electric all rights reserved 10 06/2004 by external potentiometer, to be ordered separately (see page 3 for specifications). if external potentiometer is used, the internal potentiometer is automatically disconnected. a switch on the front face of the timer allows the second contact to be used in instantaneous mode. time delay adjustable from 0.05 s to 300 h in 10 ranges (see setting procedure on the next page). external control for start of time delay re7ma and mv remote control for partial stop of time delay re7ma11bu and mv11bu conversion of second timing relay to inst antaneous mode by means of switch r2 re7ma13bu functions (see diagrams above) supply voltages relay output ca talog number weight lb (kg) symmetrical timers: on and off delay times are equal. on-delay and off-delay timer external control possible for: -partial stop of time delay -adjustment of time delay start control via external contact only 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7ma11bu 0.33 lb (0.150 kg) on-delay and off-delay timer start control via external contact only 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o dpdt re7ma13bu 0.33 lb (0.150 kg) asymmetrical timers: on and off delay times are adjusted separately. on-delay and off-delay timer external control possible for: -partial stop of time delay -adjustment of time delay start control via external contact only 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7mv11bu 0.33 lb (0.150 kg) de-energized energized open closed ta: adjustable on-delay tr = adjustable off-delay ta = t1 + t2 tr = t3 + t4 ts: partial stop time supply start c/o spdt 15/18 (25/28) y1/z2 15/16 (25/26) tr ta 15/18 15/16 x1/z2 y1/z2 t2 t1 ts t4 t3 ts start partial stop of time delay c/o spdt ta tr r2 r2 25/28 25/26 21/24 21/22 supply start c/o spdt supply c/o spdt re7m
zelio-time tm timers - re7 on-delay and off-delay timers - wiring 11 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams (for dimensions, see page 20) (1) 110-240 vac. (2) 42-48 vac or vdc. (3) 24 vac or vdc. (4) off-delay adjustment (contact 15/16 closed). (5) on-delay adjustment (contact 15/18 closed). setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. 10-position timing range selector: 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h a = adjustable on-delay (ta). b = adjustable off-delay (tr). 3. switch for converting second time delay relay to instantaneous mode (re7ma13bu). 4. leds, depending on the model: ? green led: flashes during the time delay period, permanently on outside the time delay period. ? yellow led 1: on when 1 st relay is energized. ? yellow led 2: on when 2 nd relay is energized. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 a1 15 b1 25 (21) y1 b2 26 (22) 28 (24) z2 18 16 a2 18 15 b1 b2 a1 a2 16 28 25 26 (24) (21) (22) a1 15 b1 z1 b2 y1 x1 z2 18 16 a2 18 15 b1 b2 a1 a2 16 a1 15 b1 z1 z3 b2 y1 x1 z2 18 16 a2 18 15 b1 b2 a1 a2 16 re7ma13 re7ma11bu re7mv11bu b1 a1 b2 a2 y1 z2 (1) (2) (3) b1 a1 b2 a2 x1 z2 (1) (2) (3) start by external control external control of partial stop z1 z2 a2 x1 or y1 or z1 z2 a2 z1 z3 (4) (5) z2 a2 potentiometer wiring for symmetrical timer re7ma11bu wiring precautions no galvanic insulation between supply terminals a1, a2, b1, b2 and control inputs x1, y1, z1, z2. potentiometer wiring for asymmetrical timer re7mv11bu 4 1 2 3 symmetrical timing relay 4 1 ] a 2 1 ] b 2 asymmetrical timing relay 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 off-delay timers - selection ? 1993-2004 schneider electric all rights reserved 12 06/2004 xx if the device has been stored, de-energized, for more than a month, it must be energized for about 15 seconds to activate it. subsequently, a time of > 1 s is enough to activate the time delay. if this time is not complied with, th e relay will remain energized indefinitely. by external potentiometer, to be ordered separately (see page 3 for specifications). if external potentiometer is used, the internal potentiometer is automatically disconnected. a switch on the front face of the timer allows the second contact to be used in instantaneous mode. re7rb11mw re7rb13mw partial stop not wired re7ra11bu partial stop wired re7ra11bu partial stop not wired re7rm11bu partial stop wired re7rm11bu relay output time switch set for timed output re7rl13bu relay output time switch set for instantaneous output re7rl13bu functions supply voltages relay out put catalog number weight lb (kg) on de-energization, adjustable from 0.05 s to 10 min, in 7 ranges (see setting procedure on next page). off-delay timer (times without power.) 24-240 vdc or vac 1 c/o spdt re7rb11mw 0.33 lb (0.150 kg) off-delay timer (times without power.) remote control possible for: -adjustment of time delay (terminals z1 and z2) 24-240 vdc or vac 2 c/o dpdt re7rb13mw 0.33 lb (0.150 kg) on opening of external control contact, adjustable from 0.05 s to 300 h, in 10 ranges (see setting procedure on next page). off-delay timer external control possible for: -partial stop of time delay (terminals x1 and z2) -adjustment of time delay (terminals z1 and z2) 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7ra11bu 0.33 lb (0.150 kg) on opening of low level external control contact, adjustable from 0.05 s to 300 h, in 10 ranges (see setting procedure on next page). off-delay timer external control possible for: -partial stop of time delay (terminals x1 and z2) -adjustment of time delay (terminals z1 and z2) 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7rm11bu 0.33 lb (0.150 kg) off-delay timer 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o dpdt re7rl13bu 0.33 lb (0.150 kg) de-energized energized open closed tr: adjustable off-delay tr = t1 + t2 ts: partial stop time 15/18 15/16 1s supply relay output tr a1-a2 15/18 15/16 1s supply relay 1 output 25/28 25/26 tr relay 2 output a1-a2 supply start 15/18 15/16 tr relay output a1-a2 b1-a2 b2-a2 a1-y1 b1-y1 b2-y1 110?240 vac 24 vac or vdc 42?48 vac or vdc 110?240 vac 24 vac or vdc 42?48 vac or vdc supply start 15/18 15/16 ts relay output a1-a2 b1-a2 b2-a2 x1-z2 110?240 vac 24 vac or vdc 42?48 vac or vdc t2 t1 110?240 vac 24 vac or vdc 42?48 vac or vdc partial stop a1-y1 b1-y1 b2-y1 supply start 15/18 15/16 tr relay output a1-a2 b1-a2 b2-a2 y1-z2 110?240 vac 24 vac or vdc 42?48 vac or vdc supply start 15/18 15/16 ts relay output a1-a2 b1-a2 b2-a2 x1-z2 110?240 vac 24 vac or vdc 42?48 vac or vdc t2 t1 partial stop y1-z2 supply start 15/18 15/16 relay 1 output a1-a2 b1-a2 b2-a2 110?240 vac 24 vac or vdc 42?48 vac or vdc y1-z2 relay 2 output 25/28 25/26 tr supply start 15/18 15/16 relay 1 output a1-a2 b1-a2 b2-a2 110?240 vac 24 vac or vdc 42?48 vac or vdc y1-z2 relay 2 output 25/28 25/26 tr re7r r2 r2
zelio-time tm timers - re7 off-delay timers - wiring 13 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams (1) 110-240 vac. (3) 24 vac or vdc. (2) 42-48 vac or vdc. (4) 24-240 vdc or vac. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. timing range selector: 3. switch for converting second time delay relay to instantaneous mode (for re7rl13bu). 4. leds, depending on the model: ? green led u/t: flashes during the time delay peri od, permanently on outside the time delay period. ? yellow led r1: on when 1 st relay is energized. ? yellow led r2: on when 2 nd relay is energized. ?re7rb ?? mw: the green led does not flash during the time delay period and there?s no yellow led?s. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 10-position timing range selector (re7ra, rm, rl): 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h 7-position timing range selector (re7rb): 0.05-1 s 0.5-10 s 5-100 s 1.5-10 min 0.15-3 s 1.5-30 s 15-300 s a1 15 b1 25 (21) y1 b2 26 (22) 28 (24) z2 18 16 a2 18 15 b1 b2 a1 a2 16 28 25 26 (24) (21) (22) a1 15 18 16 a2 18 15 a1 a2 16 a1 15 25 z1 26 z2 28 18 16 a2 18 15 a1 a2 16 28 25 26 a1 15 b1 z1 b2 y1 x1 z2 18 16 a2 18 15 b1 b2 a1 a2 16 re7rl13bu re7rb11mw re7rm11bu & re7ra11bu re7rb13mw (4) a1 a2 b1 a1 b2 a2 y1 z2 (1) (2) (3) b1 a1 b2 a2 x1 z2 (1) (2) (3) start on energization re7rb start by low level external control re7rm and rl remote control of partial stop z1 z2 a2 potentiometer wiring x1 or y1 or z1 z2 a2 a1 a2 y1 (1) b2 a2 y1 (2) b1 a2 y1 (3) start by external control re7ra wiring precautions re7rm and rl no galvanic insulation between supply terminals a1, a2, b1, b2 and control inputs x1, y1, z1, z2. b2 a2 y1 (2) 4 1 2 3 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 interval timers - selection ? 1993-2004 schneider electric all rights reserved 14 06/2004 xxx a switch on the front face of the timer allows the second contact to be used in instantaneous mode. by external potentiometer, to be ordered separately (see page 3 for specifications). if external potentiometer is used, the internal potentiometer is automatically disconnected. time delay adjustable from 0.05 s to 300 h in 10 ranges (see setting procedure on the next page). interval timers start on energization re7pe, pp start on opening of external control contact re7pm, pd external control for partial stop of time delay re7pm conversion of second timing relay to inst antaneous mode by means of switch r2 re7pp re7pd functions supply voltages relay out put catalog number weight lb (kg) start on energization interval timer 24 vdc or vac 110-240 vac 1 c/o spdt re7pe11bu 0.33 lb (0.150 kg) interval timer external control possible for: -adjustment of time delay 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o dpdt re7pp13bu 0.33 lb (0.150 kg) start on opening of external control contact interval timer external control possible for: -partial stop of time delay -adjustment of time delay 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7pm11bu 0.33 lb (0.150 kg) interval timer 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o dpdt re7pd13bu 0.33 lb (0.150 kg) de-energized energized open closed t: pulse time t = t1 + t2 + t3 ts: partial stop time 15/18 (25/28) 15/16 (25/26) t supply c/o spdt 15/18 y1/z2 15/16 t supply start c/o spdt 15/18 x1/z2 15/16 ts ts t1 t2 t3 supply partial stop c/o spdt r2 r2 25/28 25/26 t 21/24 21/22 supply c/o spdt supply c/o spdt r2 r2 21/24 21/22 25/28 y1/z2 25/26 t supply c/o spdt supply start c/o spdt re7p
zelio-time tm timers - re7 interval timers - wiring 15 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams (for dimensions see page 20) (1) 110-240 vac. (3) 24 vac or vdc. (2) 42-48 vac or vdc. (4) 42-48 vdc or vac: re7pp. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. 10-position timing range selector: 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h 3. switch for converting second time delay relay to instantaneous mode (depending on model). 4. leds, depending on the model: ? green led: flashes during the time delay period (except for the first 2 timing ranges), permanently on outside the time delay period. ? yellow led 1: on when 1 st relay is energized. ? yellow led 2: on when 2 nd relay is energized. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 a1 15 b1 18 16 a2 18 15 b1 a1 a2 16 a1 15 b1 25 (21) z1 b2 26 (22) 28 (24) z2 18 16 a2 18 15 b1 b2 a1 a2 16 28 25 26 (24) (21) (22) a1 15 b1 25 (21) y1 b2 26 (22) 28 (24) z2 18 16 a2 18 15 b1 b2 a1 a2 16 28 25 26 (24) (21) (22) a1 15 b1 z1 b2 y1 x1 z2 18 16 a2 18 15 b1 b2 a1 a2 16 re7pe11bu re7pm11bu re7pd13bu re7pp13bu b1 a1 b2 a2 y1 z2 (1) (2) (3) b1 a1 b2 a2 x1 z2 (1) (2) (3) (3) (4) (1) b1 a1 b2 a2 start by external control re7pm, pd external control of partial stop start on energization re7pe, pp z1 z2 a2 potentiometer wiring no galvanic insulation between supply terminals a1, a2, b1, b2 and control inputs x1, y1, z1, z2. x1 or y1 or z1 z2 a2 wiring precautions 4 1 2 3 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 repeat cycle timers - selection ? 1993-2004 schneider electric all rights reserved 16 06/2004 xxxx a switch on the front face of the timer allows the second contact to be used in instantaneous mode. by external potentiometer, to be ordered separately (see page 3 for specifications). if external potentiometer is used, the internal potentiometer is automatically disconnected. time delay adjustable from 0.05 s to 300 h in 10 ranges (see setting procedure on the next page). symmetrical repeat cycle timer re7cl, cp asymmetrical repeat cycle timer start during the on period re7cv start during the off period re7cv external control for partial stop of time delay re7cv conversion of second time delay relay to instantaneous mode by means of switch r2 re7cp functions (see diagrams above) supply voltages relay output ca talog number weight lb (kg) symmetrical relays with start during off period repeat cycle timer 24 vdc or vac 110-240 vac 1 c/o spdt re7cl11bu 0.33 lb (0.150 kg) repeat cycle timer external control possible for: -adjustment of time delay 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o dpdt re7cp13bu 0.33 lb (0.150 kg) asymmetrical, with separate adjustment of on-delay and off-delay repeat cycle timer external control possible for: -start period -adjustment of time delays -partial stop 24 vdc or vac 42-48 vdc or vac 110-240 vac 1 c/o spdt re7cv11bu 0.33 lb (0.150 kg) de-energized energized open closed t, t1 and t2: adjustable time delays ts: partial stop time t: flashing time ta: adjustable on-delay tr: adjustable off-delay ta = t1 + t2 tr = t3 + t4 15/18 (25/28) 15/16 (25/26) t t supply c/o spdt 15/18 (25/28) 15/16 (25/26) ta tr supply c/o spdt ta tr supply c/o spdt 15/18 (25/28) x1/z2 15/16 (25/26) t1 t3 t4 t2 ts ts supply partial stop c/o spdt r2 r2 25/28 25/26 t t 21/24 21/22 supply c/o spdt supply c/o spdt re7c
zelio-time tm timers - re7 repeat cycle timers - wiring 17 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams (1) 110-240 vac. (3) 24 vac or vdc. (5) start during on period: x2-z2 connected. (2) 42-48 vac or vdc. (4) 42-48 vdc or vac: re7cp13bu start during off period: x2-z2 connected. (6) off-delay adjustment (contact 15/16 closed). (7) on-delay adjustment (contact 15/18 closed). setting procedure 1. potentiometer for fine adjustment of the time delay in % of range max. setting 2 . 2. 10-position timing range selector: 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h a = adjustable on-delay (ta). b = adjustable off-delay (tr). 3. switch for converting second time delay relay to instantaneous mode (re7cp13bu). 4. leds, depending on the model: ? green led: flashes during the time delay period, permanently on outside the time delay period. ? yellow led 1: on when 1 st relay is energized. ? yellow led 2: on when 2 nd relay is energized. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 a1 15 b1 18 16 a2 18 15 b1 a1 a2 16 a1 15 b1 25 (21) z1 b2 26 (22) 28 (24) z2 18 16 a2 18 15 b1 b2 a1 a2 16 28 25 26 (24) (21) (22) a1 15 b1 z3 z1 b2 x2 x1 z2 18 16 a2 18 15 b1 b2 a1 a2 16 re7cl11bu re7cp13bu re7cv11bu b1 a1 b2 a2 x1 z2 (1) (2) (3) (3) (4) (1) b1 a1 b2 a2 b1 a1 b2 a2 x2 z2 (3) (2) (1) (5) start period selection re7cv external control of partial stop re7cp start on energization z1 z2 a2 z1 z3 (6) (7) z2 a2 potentiometer wiring re7cp no galvanic insulation between supply terminals a1, a2, b1, b2 and control inputs x1, y1, z1, z2. x1 or y1 or z1 z2 a2 wiring precautions potentiometer wiring re7cv 4 1 2 3 4 1 ] a 2 1 ] b 2 asymmetrical timing relay symmetrical timing relay 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 star-delta timer - selection ? 1993-2004 schneider electric all rights reserved 18 06/2004 xxxxx adjustable time delay for ?star? operation and fixed (50 ms) for the changeover from ?star? to delta? operation in order to ensure sufficient breaking time. time delay adjustable from 0.05 s to 300 h in 10 ranges (see setting procedure on the next page). timer for ?star-delta? starters with double on-delay re7ya with interval contact for star operation re7yr functions (see diagrams above) supply voltages relay output ca talog number weight lb (kg) with double on-delay 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o dpdt re7ya12bu 0.33 lb (0.150 kg) with interval contacts for star operation 24 vdc or vac 42-48 vdc or vac 110-240 vac 2 c/o with common point dpdt re7yr12bu 0.33 lb (0.150 kg) de-energized energized open closed t: adjustable time delay (star) t3: switching time = 50 ms t t3 15/18 15/16 25/28 25/26 supply c/o1 c/o2 "star" "delta" t t3 17/18 17/28 supply c/o1 c/o2 "star" "delta" re7y 1
zelio-time tm timers - re7 star-delta timer - wiring 19 06/2004 ? 1993-2004 schneider electric all rights reserved setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. 10-position timing range selector: 0.05-1 s 0.5-10 s 5-100 s 1.5-30 min 1.5-30 h 0.15-3 s 1.5-30 s 15-300 s 1-300 min 15-300 h 3. leds, depending on the model: ? green led: flashes during the time delay period (except for the first 2 timing ranges), permanently on outside the time delay period. ? yellow led 1: on when 1 st relay is energized. ? yellow led 2: on when 2 nd relay is energized. adjustment of the time delay ? select the timing range immediately greater than the time required, using selector switch 2 . ? example: required time 12 s; range selected 30 s. ? using potentiometer 1 display the required timing value as a % of value 2 . percentage of setpoint = trequired x 100 trange trequired = 12 sec. 12 x 100 trange = 30 sec. 30 v2 u2 w2 w1 v1 u1 f2 k2 1 2 3 4 5 6 k1 1 2 3 4 5 6 m1 k3 1 2 3 4 5 6 l1 l2 l3 1 2 3 4 5 6 3 k1 a1 a2 96 f2 15 16 k1t 21 22 k3 21 22 13 14 s1 s2 k1t a1 a2 13 14 k1 k2 a1 a2 k3 a1 a2 25 28 k1t k1t = re7ya relay 21 22 k1 14 13 k2 a1 re7ya terminal block 15 b1 25 b2 28 26 z2 18 16 a2 18 15 b1 b2 a1 a2 16 28 25 26 yn ? n 95 f3 l1 power wiring re7ya12bu control wiring ?star-delta function with double on-delay timing v2 u2 w2 w1 v1 u1 f2 k2 1 2 3 4 5 6 k1 1 2 3 4 5 6 m1 k3 1 2 3 4 5 6 l1 l2 l3 1 2 3 4 5 6 3 k1 a1 a2 95 96 f2 21 22 k3 f3 21 22 13 14 s1 s2 k1t k1t = re7yr relay a1 a2 k3 a1 a2 k2 a1 a2 14 13 53 54 k2 28 17 21 22 k1 18 17 k1t k2 14 13 k1 b1 17 17 a1 re7yr terminal block b2 28 26 z2 18 16 a2 18 b1 b2 a1 a2 16 28 17 26 l1 yn ? n power wiring re7yr12bu no galvanic insulation between supply terminals a1, a2, b1, b2 and control input z2. this terminal must therefore never be used (factory setting). control wiring ?star-delta? function with interval contact for ?star? operation 1 1 2 3 40 30 s x. % 1 2 = 40 %
zelio-time tm timers - re7 dimensions ? 1993-2004 schneider electric all rights reserved 20 06/2004 x rail mounting direct panel mounting 0.89 22.5 3.15 80 3.07 78 3.52 89.5 3.23 82 ? 0.16 4 0.24 6 0.24 6 3.07 78 dual dimensions = in mm
zelio-time tm timers - re7 other wiring configurations 21 06/2004 ? 1993-2004 schneider electric all rights reserved z it is advisable to follow the recommended wiring diagrams detailed above and on previous pages. however, the connections below are possible if the restrictions given are taken into account. connection of an external control contact without using terminal z2: ? possible on all re7 timers with exte rnal control option except re7ra11bu ? vdc supply only connection of telemecanique 3-wire npn or pnp sensor without using terminal z2: ? only possible on timer re7 bu ? vdc supply only z2 a2 z2 y1 or x1 y1 or x1 y1 or x1 a2 z2 a2 a1, b1, or b2 a1, b1, or b2 a1, b1, or b2 control of several timers with a single external control contact bn bk npn pnp bu y1 a1, b1, or b2 ? + z2 a2 24 v or 48 v connection of telemecanique 3-wire npn or pnp sensor ? + z2 a1, b1 or b2 y1 or x1 a2 ? + z2 a2 a1, b1 or b2 y1 or x1 bn bk npn bu y1 ? + b1b2 z2 a2 24 v or 48 v bn bk pnp bu y1 ? + b1b2 z2 a2 24 v or 48 v
zelio-time tm timers - re8 application data ? 1993-2004 schneider electric all rights reserved 22 06/2004 the re8 range of timers are designed for simple and repetitive applications, providing basic functions. each relay has: ? a single timing range ? a spdt output relay these products have a transparent, hinged cover on t heir front face to prevent any accidental alteration of the settings. this cover can be sealed. environment conforming to standards iec 61812-1, en 61812-1 product approvals ce marking zelio time timer conforms to european regulations relating to ce marking ambient air temperature around the device storage -40 to 185 f (-40 to + 85 c) operation -4 to 140 f (-20 to + 60 c) permissible relative humidity range conforming to iec 60721-3-3 15-85 % environmental class 3k3 vibration resistance conforming to iec 60068-2-6, 10 to 55 hz a = 0.35 ms shock resistance conforming to iec 60068-2-27 15 gn - 11 ms degree of protection housing ip 50 terminals ip 20 degree of pollution conforming to iec 60664-1 3 overvoltage category conforming to iec 60664-1 iii rated insulation voltage conforming to iec 250 v conforming to ul and csa 300 v test voltage for insulation tests dielectric test ul and csa 2200 v, iec 2000 v shock wave 4.8 kv voltage limits power supply circuit 0.9-1.1 uc frequency limits power supply circuit 50/60 5 % hz disconnection value power supply circuit > 0.1 uc mounting position without derating in relation to normal vertical mounting plane any position connection maximum c.s.a. stranded wire without cable end 2 # 14 awg (2 x 2.5 mm 2 ) stranded with cable end 2 # 16 awg (2 x 1.5 mm 2 ) tightening torque 4.5-9.9 lb-in (0.6-1.1 n m) immunity to electromag netic interference (emc) (application class 2 conforming to en 61812-1) electrostatic discharge conforming to iec 61000-4-2 level 3 (6 kv contact, 8 kv air) electromagnetic fields conforming to iec 61000-4-3 level 3 (10 v/m) fast transients conforming to iec 61000-4-4 level 3 (2 kv) shock waves conforming to iec 61000-4-5 level 3 (2 kv) radiated and conducted emissions cispr11 group 1 class a cispr22 class a consumption consumption re8ta, ra, cl, pe, pu, pt 24 vac 110 vac 240 vac 380 vac 415 vac 24 vdc 0.7 va 1.8 va 8.5 va ? ? 0.5 w re8yg, rb 0.9 va 2.5 va 13 va ? ? 0.5 w re8ya 0.9 va 2.5 va 13 va 8 va 9 va 0.7 w ? file e164353 cnn nkcr file lr 89150 guide 3211 07 gl
zelio-time tm timers - re8 application data 23 06/2004 ? 1993-2004 schneider electric all rights reserved example: an lc1f185 contactor supplied with 115 v/50 hz for a consumption of 55 va or a current consumption equal to 0.1 a and cos ? = 0.3. for 0.1 a, curve 1 indicates a durability of approximately 1.5 million operating cycles. as the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles, as indicated by curve 2. for cos ? = 0.3: k = 0.6 the electrical durability therefore becomes: 1.5 10 6 operating cycles x 0.6 = 900,000 oper ating cycles. the product life expressed above is based on average usage and normal operating conditions. actual operating life will vary with conditions. the above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life. for information on the listed warranty offered on this product, refer to the terms and conditions of sale found in the digest. time delay specifications setting accuracy as % of the full scale value 20 % repeat accuracy < 1 % influence of voltage in the voltage range, 0.9-1.1 un < 2.5 % influence of temperature < 0.2 % / c immunity to micro-breaks 3 ms minimum control pulse 26 ms (except re8yg : 60 ms) reset time 50 ms output circuit specifications maximum switching voltage 250 vac/vdc mechanical durability in millions of operating cycles 20 current limit ith 8 a rated operational limits at 70 c 24 v 115 v 250 v conforming to iec 60947-5-1/1991 and vde 0660 ac-15 3 a3 a3 a dc-13 2 a 0.2 a 0.1 a ul and csa current ratings resistive rating 5 a nema / ul b300 inductive rating 3600 va make rating 360 va break rating 5 a carry minimum switching capacity 12 v/10 ma contact material nickel silver 90/10 remote control input specifications signal delivered by control input y1 no galvanic insulation between this input and the power supply no-load voltage supply voltage switching current < 10 ma maximum distance 164 ft (50 m) compatibility 2-wire sensors with leakage current < 1 ma 10 1 0.1 0.01 012345678 a curve 1 ac load electrical durabilit y of contacts on resistive load in millions of operating cycles 1 0.6 0.5 0.9 0.8 0.7 0.4 0.3 1 0.8 0.6 0.5 0.4 0.3 0.2 k power factor curve 2 reduction factor k for inductive loads (applies to values taken from the durability curve opposite) re8 k + ? 300 40 30 200 100 50 20 10 0.1 0.2 0.5 1 2 5 20 10 1 2 3 a amps dc load load limit curve are8rb butq 1 l/r = 20 ms 2 l/r with load protection diode 3 resistive load
zelio-time tm timers - re8 on-delay timers - selection ? 1993-2004 schneider electric all rights reserved 24 06/2004 x/x for easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. example: re8ta11butq timing range 0.1-10 s, recommended use 1-10 s. also available in pack of one; delete tq from the end of the catalog number. example: re8ta11bu. orders must specify standard pack quantity or multiples of that quantity. on-delay timers start on energization re8ta relay output supply voltages timing range catalog number standard pack quantity weight lb (kg) 1 c/o spdt 24 vdc or vac 110-240 vac 0.1-3 s re8ta61butq 10 0.24 lb (0.110 kg) 0.1-10 s re8ta11butq 10 0.24 lb (0.110 kg) 0.3-30 s re8ta31butq 10 0.24 lb (0.110 kg) 3-300 s re8ta21butq 10 0.24 lb (0.110 kg) 20 s-30 min re8ta41butq 10 0.24 lb (0.110 kg) off-delay timers off-delay timer with control contact re8ra self-powered re8rb relay output supply voltages timing range catalog number standard pack quantity weight lb (kg) control contact 1 c/o spdt 24 vdc or vac 0.1-10 s re8ra11btq 10 0.24 lb (0.110 kg) 0.3-30 s re8ra31btq 10 0.24 lb (0.110 kg) 3-300s re8ra21btq 10 0.24 lb (0.110 kg) 110-240 vac 0.1-10 s re8ra11futq 10 0.24 lb (0.110 kg) 0.3-30 s re8ra31futq 10 0.24 lb (0.110 kg) 3-300 s re8ra21futq 10 0.24 lb (0.110 kg) 20 s-30 min re8ra41futq 10 0.24 lb (0.110 kg) self-powered 1 c/o spdt 24 vdc or vac 110-240 vac 0.05-0.5 s re8rb51butq 10 0.24 lb (0.110 kg) 0.1-10 s re8rb11butq 10 0.24 lb (0.110 kg) 0.3-30 s re8rb31butq 10 0.24 lb (0.110 kg) repeat cycle timer symmetrical re8cl relay output supply voltages timing range catalog number standard pack quantity weight lb (kg) 1 c/o spdt 24 vdc or vac 110-240 vac 0.1-10 s re8cl11butq 10 0.24 lb (0.110 kg) de-energized energized open closed t: adjustable on-delay 15/18 15/16 t supply c/o spdt re8ta 15/18 15/16 t supply start c/o spdt 15/18 15/16 t > 80 ms supply c/o spdt de-energized energized open closed t: adjustable off-delay de-energized energized open closed t: flashing time 15/18 15/16 t t supply c/o spdt
zelio-time tm timers - re8 on-delay timers - wiring 25 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams (1) 110-240 vac. (2) 24 vdc or vac. (3) 24 vdc. (4) 24 vac or 110-240 vac. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. marking of maximu m time delay value. 3. leds, depending on the model: ? yellow led: illuminates when the output relay is energized. ? yellow led: illuminates when the re8 is energized adjustment of the time delay ? the maximum value of the timing range is printed on the product, 2 . ? example: re8ta61butq; maximum time delay: 3 s. ? time required 2.4 s; using potentiometer 1 set the value of the time delay required as a % of value 2 : percentage of setpoint = trequired x 100 trange trequired = 2.4 sec. 2.4 x 100 trange = 3 sec. 3 a1 15 b1 18 16 a2 18 15 b1 a2 a1 16 a1 15 b1 18 16 a2 18 15 b1 a2 a1 16 re8ta,cl re8ra re8rb a1 15 b1 18 16 a2 18 15 b1 a2 a1 16 (2) (1) b1 a2 a1 a1 a2 y1 (4) (3) + ? re8ta, rb, cl re8ra 3 1 2 80 3 s x...... % 1 2 = 80 %
zelio-time tm timers - re8 interval timers - selection ? 1993-2004 schneider electric all rights reserved 26 06/2004 for easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. example: re8pe11butq timing range 0.1-10 s, recommended use 1-10 s. correct operation of the star-delta starter is only possible if the wiring diagram on page 27 is strictly followed. orders must specify standard pack quantity or multiples of that quantity. interval timers start on energization re8pe start on opening of external control contact re8pd start on de-energization re8pt relay output supply voltages timing range catalog number standard pack quantity weight lb (kg) on energization 1 c/o spdt 24 vdc or vac 110-240 vac 0.1-10 s re8pe11butq 10 0.24 lb (0.110 kg) 0.3-30 s re8pe31butq 10 0.24 lb (0.110 kg) 3-300 s re8pe21butq 10 0.24 lb (0.110 kg) by control contact 1 c/o spdt 24 vdc or vac 0.1-10 s re8pd11btq 10 0.24 lb (0.110 kg) 0.3-30 s re8pd31btq 10 0.24 lb (0.110 kg) 3-300s re8pd21btq 10 0.24 lb (0.110 kg) 110-240 vac 0.1-10 s re8pd11futq 10 0.24 lb (0.110 kg) 0.3-30 s re8pd31futq 10 0.24 lb (0.110 kg) 3-300 s re8pd21futq 10 0.24 lb (0.110 kg) on de-energization 1 c/o spdt 24 vdc or vac 110-240 vac 0.05-1 s re8pt01butq 10 0.05 lb (0.110 kg) timers for star-delta starters with contact for switching to star connection re8yg with double on-delay period re8ya relay output supply voltages timing range catalog number standard pack quantity weight lb (kg) 1 c/o spdt 24 vdc or vac 110-240 vac 0.1-10 s re8yg11butq 10 0.24 lb (0.110 kg) 0.3-30 s re8yg31butq 10 0.24 lb (0.110 kg) 3-300 s re8yg21butq 10 0.24 lb (0.110 kg) 1 n/c + 1 n//o 24 vdc or vac 0.3-30 s re8ya32btq 10 0.24 lb (0.110 kg) 100-240 vac 0.3-30 s re8ya32futq 10 0.24 lb (0.110 kg) 380-415 vac 0.3-30 s re8ya32qtq 10 0.24 lb (0.110 kg) de-energized energized open closed t: pulse time 1 15/18 15/16 t supply c/o spdt 15/18 y1a1 15/16 t supply start c/o spdt 15/18 15/16 t < t > 80 ms supply c/o spdt re8pe de-energized energized open closed t: adjustable time delay (star) t 50 ms 15/18 15/16 supply star delta t 80 ms 15/16 25/28 supply n/c n/o
zelio-time tm timers - re8 interval timers - wiring 27 06/2004 ? 1993-2004 schneider electric all rights reserved wiring recommended wiring diagrams interval timers (1) 110-240 vac. (3) 24 vdc. (2) 24 vdc or vac. (4) 24 vac or 110-240 vac. timers for star-delta starters note: correct operation of the star-delta starter a ssociated with the re8yg is only possible if the wiring diagram is strictly followed. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. marking of maximu m time delay value. 3. leds, depending on the model: ? yellow led: illuminates when the output relay is energized. ? yellow led: illuminates when the re8 is energized adjustment of the time delay ? the maximum value of the timing range is printed on the product, 2 . ? example: re8pe11butq; maximum time delay: 10 s. ? time required 2.4 s; using potentiometer 1 set the value of the time delay required as a % of value 2 : percentage of setpoint = trequired x 100 trange trequired = 2.4 sec. 2.4 x 100 trange = 3 sec. 10 a1 15 b1 18 16 a2 18 15 16 b1 a2 a1 a1 15 b1 18 16 a2 18 15 16 b1 a2 a1 a1 15 25 28 16 a2 16 15 a2 a1 28 25 a1 15 b1 18 16 a2 18 15 b1 a2 a1 16 re8tpe re8pd re8pt re8ya re8yg a1 15 y1 18 16 a2 18 15 a2 a1 16 a1 15 b1 18 16 a2 18 15 16 b1 a2 a1 (2) (1) b1 a2 a1 a1 a2 y1 (4) (3) + ? re8pe, pt re8pd ? km2 ? km3 ? km1 u1 v1 w1 u2 v2 w2 ? q1 l1 l2 l3 ? rth y ? km2 ? km3 ? k1t (1) ? km1 y a1 a2 a1 a2 a1 a2 a1 a2 ? km3 ? km2 ? km1 ? s2 ? km1 ? k1t ? k1t 15 16 25 28 ? s1 ? fu1 ? rth l (1) k1t: re8ya32 tq re8yg, re8ya re8yg re8ya ? km3 ? km2 ? k1t (1) ? km1 y a1 a2 a1 a2 a1 a2 a1 a2 ? km3 ? km2 ? km1 ? s2 ? km1 ? k1t (1) 16 15 ? km1 ? km2 ? s1 ? fu1 ? rth l (1) k1t: re8yg 1 tq 3 1 2 24 10 s x...... % 1 2 = 24 %
zelio-time tm timers - re8 dimensions ? 1993-2004 schneider electric all rights reserved 28 06/2004 rail mounting direct panel mounting 0.89 22.5 3.15 80 3.07 78 3.52 89.5 3.23 82 ? 0.16 4 0.24 6 3.07 78 0.24 6 dual dimensions = in mm
zelio-time tm timers - re8 other wiring configurations 29 06/2004 ? 1993-2004 schneider electric all rights reserved control of several timers with a single external control contact re8ra, pd the external control contact c may be an electronic control device, for example a 2-wire sensor. in this case a1-a2 = 24 vdc and the control device can only control up to a maximum of 4 timers. connection of 2-wire vdc sensor leakage current (open state) if < 1 ma. y1 a2 y1 a2 y1 a2 a1 a1 a1 c y1 ? + a1 a2 if
zelio-time tm timers - re9 application data ? 1993-2004 schneider electric all rights reserved 30 06/2004 the re9 range of timers is designed for simple, repe titive applications with short and intensive cycles because their solid state output relays pr ovides very high electrical durability. each product has a single timing range. each relay has a wide voltage range from 24 to 240 v. the range has 9 catalog numbers with 3 model types: ? re9ta: on-delay ? re9ra: off-delay ? re9ms: multifunction these products have a transparent, hinged cover on thei r front face to avoid any accidental alteration of the setting. this cover can be sealed. environment conforming to standards iec 61812-1, en 61812-1 product approvals ce marking zelio time timer conforms to european regulations relating to ce marking ambient air temperature around the device storage -40 to 185 f (-40 to + 85 c) operation -4 to 140 f (-20 to + 60 c) permissible relative humidity range conforming to iec 60721-3-3 15-85 % environmental class 3k3 vibration resistance conforming to iec 60068-2-6, 10 to 55 hz a = 0.35 ms shock resistance conforming to iec 60068-2-27 15 gn - 11 ms degree of protection housing ip 50 te r m i n a l s i p 2 0 degree of pollution conforming to iec 60664-1 3 overvoltage category conforming to iec 60664-1 iii rated insulation voltage conforming to iec 250 v conforming to csa 300 v test voltage for insulation tests dielectric test 2.5 kv shock wave 4.8 kv voltage limits power supply circuit 0.9-1.1 uc frequency limits power supply circuit 50/60 5 % hz disconnection value power supply circuit > 0.1 uc mounting position without derating in relation to normal vertical mounting plane any position connection maximum c.s.a. stranded wire without cable end 2 # 14 awg (2 x 2.5 mm 2 ) stranded with cable end 2 # 16 awg (2 x 1.5 mm 2 ) tightening torque 4.5-9.9 lb-in (0.6-1.1 n m) immunity to electromag netic interference (emc) (application class 2 conforming to en 61812-1) electrostatic discharge conforming to iec 61000-4-2 level 3 (6 kv contact, 8 kv air) electromagnetic fields conforming to iec 61000-4-3 level 3 (10 v/m) fast transients conforming to iec 61000-4-4 level 3 (2 kv) shock waves conforming to iec 61000-4-5 level 3 (2 kv) radiated and conducted emissions cispr11 group 1 class a cispr22 class a ? file e164353 cnn nkcr file lr 89150 guide 3211 07 gl
zelio-time tm timers - re9 application data 31 06/2004 ? 1993-2004 schneider electric all rights reserved re9ms at 60 c maximum current: up to 48 v/400 ma, from 48 to 240 v/300 ma. power supply specifications type of timer re9ta on-delay re9ra off-delay re9ms multifunction supply voltage 24-240 vdc or vac 24-240 vac 24-240 vdc or vac see page 33. voltag e limits power supply circuit 0.85-1.1 un frequency 50-60 5 % hz control contact mechanical only in series between y2 and a2 in series maximum length of connecting cable from contact to re9 ? 65.6 ft (20 m) ? control input consumption input y2 ? 5 ma ? time delay specifications setting accuracy < 20 % repeat accuracy < 1 % minimum reset time after the time delay period 100 ms minimum switching time ?40? maximum immunity to micro-breaks during the time delay period 100 ms 2 ms 70 ms after the time delay period 2 ms ? 2 ms temperature drift 0.1 % / c switching specifications (solid state type) maximum continuous current at ambient temperature: 20 c 0.7 a (minimum 10 ma) ul maximum i nductive ratings make 7.0 amp @ 250 vac break 0.7 amp @ 250 vac carry 0.7 amp @ 250 vac make 0.7 amp @ 250 vdc break 0.7 amp @ 250 vdc maximum overload current vde 0435 part. 303, 4.8.3/class ii 15 a for 10 ms maximum voltage drop closed state at 0.7 a: 3 v leakage current open state 6 ma 1 ma 6ma maximum dissipated power 2.5 w 4 w 2.5 w derating for temperature > 20 c none (ma) electrical durability in millions of op erating cycles > 100
zelio-time tm timers - re9 on-delay timers - selection ? 1993-2004 schneider electric all rights reserved 32 06/2004 for easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. example: re9ta11mw timing range 0.1-10 s, recommended use 1-10 s. on-delay timers power supply circuit function timing range catalog number weight lb (kg) 24-240 vac or vdc on-delay 0.1-10 s re9ta11mw 0.24 lb (0.110 kg) 0.3-30 s re9ta31mw 0.24 lb (0.110 kg) 3-300 s re9ta21mw 0.24 lb (0.110 kg) 40 s - 60 min re9ta51mw 0.24 lb (0.110 kg) off-delay timers power supply circuit function timing range catalog number weight lb (kg) 24-240 vac off-delay 0.1-10 s re9ra11mw7 0.24 lb (0.110 kg) 0.3-30 s re9ra31mw7 0.24 lb (0.110 kg) 3-300 s re9ra21mw7 0.24 lb (0.110 kg) 40 s - 60 min re9ra51mw7 0.24 lb (0.110 kg) de-energized energized open closed t: adjustable on-delay t supply load control contact k re9ta t supply load control contact k de-energized energized open closed t: adjustable off-delay
zelio-time tm timers - re9 multi-function timers - selection 33 06/2004 ? 1993-2004 schneider electric all rights reserved for easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. example: re9ms21mw timing range 3-30 s, recommended use 30-300 s. multifunction timers on-delay interval repeat cycle start on energization of the load repeat cycle start on de-energization of the load power supply circuit function timing range catalog number weight lb (kg) 24-240 vac or vdc on-delay 0.3-30 s and 0.1-10 s re9ms21mw 0.24 lb (0.110 kg) 24-240 vac interval 24-240 vac repeat cycle start on energization of the load. 24-240 vac repeat cycle start on de-energization of the load. de-energized energized open closed t: time delay 1 t supply load control contact k t supply load control contact k = t = t supply load control contact k = t = t supply load control contact k re9ms
zelio-time tm timers - re9 dimensions ? 1993-2004 schneider electric all rights reserved 34 06/2004 rail mounting direct panel mounting 0.89 22.5 3.15 80 3.07 78 3.52 89.5 3.23 82 ? 0.16 4 0.24 6 3.07 78 0.24 6 dual dimensions = in mm ? 0.16 4 0.24 6 3.07 78 0.24 6 dual dimensions = in mm
zelio-time tm timers - re9 wiring 35 06/2004 ? 1993-2004 schneider electric all rights reserved recommended wiring diagrams selection of timing range x3-x4 not linked: range 3-300s (factory configuration). x3-x4 linked: range 0.1-10 s. note: for supply voltages greater than 30 v, the rated voltage of the load is equal to the supply voltage. for a supply voltage of 24 v, the voltage drop withi n the re9 timer must be taken into account (about 3 v); a coil with a nominal voltage of 21 v must therefore be selected for the load. setting procedure 1. potentiometer for fine adjustment of the time delay, gr aduated in % of range max. setting 2 . 2. marking of maximu m time delay value. 3. leds, depending on the model: ? yellow led: flashes during the time delay period; permanently on outside the time delay period. adjustment of the time delay ? the maximum value of the timing range is printed on the product, 2 . ? example: re9ms21mw; maximum time delay: 10 s (x3-x4 linked). ? time required 2.4 s; using potentiometer 1 set the value of the time delay required as a % of value 2 : percentage of setpoint = trequired x 100 trange trequired = 2.4 sec. 2.4 x 100 trange = 3 sec. 10 a1 l x1 x3 x2 x4 re9ms a2 l a1 a1 k x3 x4 re9-ms supply vac or vdc a2 l a1 a1 k x1 x3 x4 re9-ms supply vac re9ms on-delay interval link to be made between terminals x1 and x4. a2 la1 a1 k x2 x3 x1 x4 re9-ms supply vac a2 la1 a1 k x2 x3 x4 re9-ms supply vac repeat cycle start on energization of the load repeat cycle start on de-energization of the load link to be made between terminals x2 and x4 on one side and x1 and x2 on the other side. link to be made between terminals x2 and x4. 3 1 2 24 10 s x...... % 1 2 = 24 %
catalog no. 9050ct0001r6/04 june 2004 ? 1993-2004 schneider electric all rights reserved replaces 9050ct0001 dated 10/00. schneider electric usa 8001 highway 64 east knightdale, nc 27545 1-888-squared (1-888-778-2733) www.us.squared.com schneider electric canada 19 waterman avenue, m4b 1 y2 toronto, ontario 1-800-565-6699 www.schneider-electric.ca


▲Up To Search▲   

 
Price & Availability of RE9MSXXXX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X