  series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 1 of 9 north america only features: models single output model max output power (w) * output voltage range (v) output current (a) input voltage (vac/hz) input voltage (vdc) efficiency (%) amer90-50180az 90 36-50 1.8 90-277/47-440 120-390 91 amer90-36250az 90 24-36 2.5 90-277/47-440 120-390 90 AMER90-24375AZ 90 12-24 3.75 90-277/47-440 120-390 90 * exceeding the maximum output power w ill permanently damage the converter note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifications parameters conditions typical maximum units inrush current <2ms 115vac 40 a 230vac 50 leakage current 115vac 0.5 ma 230vac 0.75 ac current 115vac 1.4 a 230vac 0.46 power factor 115vac 0.98 230vac 0.94 external fuse 250v/2.5a start up time 700 ms surge voltage 2sec 440 v output specifications parameters conditions typical maximum units current accuracy 3 % line regulation ll-hl 1 % load regulation 0-100% load 0.3 % ripple & noise * 20mhz bandwidth 75 mv p-p hold-up time 100 ms current adjustment range 100-0 % minimum load voltage see the models table * tested with 0.1f (c/c) or (m/c) and 47f (e/c) parallel capacitors at the end. isolation specifications parameters conditions typical rated units tested i/o voltage 3sec 3000 vac isolation resistance 500vdc >1000 m ? isolation capacitance 1000 pf general specifications parameters conditions typical maximum units switching frequency 100 khz over current protection 95-110% of iout ? ac-dc constant current led driver ? over temperature protection ? input range 90-277vac/47-440hz ? waterproof case rated ip68 ? high efficiency up to 91% ? power factor correction ? operating temperature -40 to 85c ? scp, over current protection
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 2 of 9 north america only general specifications (continued) parameters conditions typical maximum units over voltage protection 110% of vout short circuit protection continuous short circuit restart auto recovery over temperature protection >105c operating temperature with derating over 55c -40 to +85 o c maximum case temperature 100 o c storage temperature -40 to +95 o c temperature coefficient 0.02 % / o c cooling free air convection humidity 95 % rh case material aluminum potting epoxy (ip67 rated) wires ul1015 18awg *20cm weight 750 g dimensions (l x h x w) 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm mtbf >400,000 hrs (mil-hdbk-217f at +25c) safety specifications parameters agency approvals culus, ce standards ul8750, ul60950-1, en55022, class b, en60529(ip68), en61347-1, en61347-2-13 dimensions
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 3 of 9 north america only application circuit temperature graph -40 -20 020406080 100 100 80 60 40 20 0 free air convection 55 o c safe operating area ambient temperature o c 85 efficiency vs. input voltage and output current (cc load) amepr90-50180az model number maximum pot value (k ? ) amer90-50180az 15.00 amer90-36250az 24.00 AMER90-24375AZ 16.95
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 4 of 9 north america only efficiency vs. input voltage and output current (cc load) (continued) amer90-36250az AMER90-24375AZ
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 5 of 9 north america only pfc value vs. output load current (cc load) amepr90-50180az amer90-36250az
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 6 of 9 north america only pfc value vs. output load current (cc load) (continued) AMER90-24375AZ constant current mode vs. constant voltage mode amepr90-50180az
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 7 of 9 north america only constant current mode vs. constant voltage mode (continued) amer90-36250az AMER90-24375AZ
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 8 of 9 north america only output current vs. radj amepr90-50180az amer90-36250az
series amer90-az up to 3.75a | ac-dc led driver www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.j 9 of 9 north america only output current vs. radj (continued) AMER90-24375AZ note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency cert ifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an am bient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary an d may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sys tems or other such applications which necessitate specific safety and regulatory standards ot her the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s st andard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AMER90-24375AZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X