universal phase angle trigger module AFM-11 x10221 introduction this single phase or phase to phase trigger module uses variable phase angle control with adjustable signal matching, selectable soft start and integral current limit input. the pulse train output is reliable, powerful and universally applicable to resistive or inductive loads. the power transformer is remote for increased reliability and wide operational voltage capability. adjustable current limit allows feedback control and via a few external parts, this can also give voltage or speed control of ac or dc loads. the module is fully enclosed for safety and eligibility in industrial environments. applications applicable to most ac or dc, resistive or inductive loads via thyristor, triac or hybrid diode stacks on single phase to neutral or phase to phase supplies, within voltage limits. features fires triacs or thyristors up to 480v, 50/60 hz supplies. selectable soft start function. adjustable current limit control. pulse train firing via isolation transformer. consumes under 2 watts. installation
order code state part number: afm11 optional extras include: potentiometer, soft start capacitor, supply transformer, complete assemblies, filter. when ordering a filter the current of the load is required. power connections specifications signal span minimum 0 to 2v dc ac input supply 18 to 24v rms @ 75ma signal span maximum 0 to 25v dc auxiliary output 5v dc @ 5ma protected signal zero offset 0 to 30% of span thyristor line voltage 110 to 480v rms @ 50/60 hz signal input resistance 5000 w 20% manual potentiometer 2k w , 5k w or 10k w trigger pulse height 8v open circuit limit feedback input 2v min, 20v max. into 5k w trigger pulse rating 250ma in to 10 w soft start time constant 0.1 second per m f trigger isolation voltage 2500v rms storage temperature -20 c to +85 c trigger shorted output protected operating temperature 0 c to 75 c recommendations other documents available on request, which may be appropriate for your application:- code identity description x10229 rfi filtering recommendations - addressing emc directive x10213 ita interaction, us es for phase angle and for burst fire control. x10255 sra safety requirements - addressing the low voltage directive (lvd)including :- thermal data/cooling ; ?live? parts warning & earth requirements; fusing recommendations. ap02/4 cos ual conditions of sale. note it is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the i.e.e. wiring regulations (bs7671) by suitably qualified/trained personnel. the regulations contain important requirements regarding safety of electrical equipment (for international standards refer to i.e.c. directive iec 950). united automation limited 237 liverpool road, birkdale tel (01704) - 565713 southport, pr8 4pj fax (01704) - 569760 england e-mail 100530,2262 page no. 2 of 2 issue 1 date 15/09/98 @ comperserve.com fusing it is recommended to use semiconductor (fast acting) type fuses or circuit breakers (semiconductor - mcb) for unit protection and an appropriate safety fuse for unit supply (f1a). on initial ?switch on? some loads may need an increased factor of safety (f of s) for unit and/or device protection. (see sra datasheet for further information). ce marking this product family carries a ?ce marking?. these phase angle controllers need a suitable remote filter. for information see recommendation section and contact our sales desk. (see declaration of conformity).
|