  Datasheet File OCR Text:
  low-cost digital i/o device for usb overview the national instruments USB-6501 is a portable digital i/o device, providing reliable data acquisition and control at a low price. with plug-and-play usb connectivity, the ni USB-6501 is simple enough for home/academic applications but robust and versatile enough for laboratory/industrial applications. the board-only version is ideal for embedded oem applications. hardware the USB-6501 is a full-speed usb device that provides 24 dio lines and a 32-bit counter. the 24 digital lines are arranged in three ports: p0.<0..7>, p1.<0..7>, and p2.<0..7>. p2.7 can also function as a 32-bit counter. you can individually program each of the USB-6501 dio lines as a di or do line and use the dio lines to monitor or control digital signals. all samples of the di lines and updates of the do lines are software-timed. the default con?uration of the USB-6501 dio ports is open-drain, for 5 v operation with an onboard 4.7 k pull-up resistor. you can add an external, user-provided, pull-up resistor to increase the source current drive up to 8.5 ma per line. each dio signal is protected against overvoltage, undervoltage, and overcurrent conditions, as well as esd events. at system startup and reset, the hardware sets all dio lines to high-impedance inputs. product bus digital i/o lines counter/ timers current drive logic level industrial feature set ni 6501 usb 24 1 8.5 ma 5 v ttl / cmos table 1. USB-6501 features small, portable digital i/o device 24 digital i/o lines, one 32-bit counter overvoltage protection, 8.5 ma current drive full-speed usb (12 mb/s) bus interface built-in screw terminals with removable connectors for easier connectivity oem version available with 34-pin idc mass termination connectivity operating systems windows vista/xp/2000 mac os x 1 linux ? recommended software labview labwindows /cvi measurement services software (included) ni-daqmx driver software measurement & automation explorer con?uration utility 1 mac os x and linux users need to download ni-daqmx base. ni USB-6501 gnd +5v p1.7 p1.6 p1.5 p1.4 gnd gnd p2.7 p2.6 p2.5 p2.4 p2.3 p2.2 p2.1 p2.0 gnd +5v p1.3 p1.2 p1.1 p1.0 gnd gnd p0.7 p0.6 p0.5 p0.4 p0.3 p0.2 p0.1 p0.0 terminal signal 1 gnd 2 +5 v 3 p1.7 4 p1.6 5 p1.5 6 p1.4 7 gnd 8 gnd 9 p2.7 10 p2.6 11 p2.5 12 p2.4 13 p2.3 14 p2.2 15 p2.1 16 p2.0 terminal signal 17 p0.0 18 p0.1 19 p0.2 20 p0.3 21 p0.4 22 p0.5 23 p0.6 24 p0.7 25 gnd 26 gnd 27 p1.0 28 p1.1 29 p1.2 30 p1.3 31 +5 v 32 gnd figure 1. USB-6501 pinout
the data acquisition device does not drive the signal high or low. each line has a weak pull-up resistor connected to it. you can con?ure p2.7 as the source for a 32-bit counter. in this mode, the device counts high to low transitions (falling edges) on p2.7. you can arm and disarm the counter and read or reset the count through software. the USB-6501 supplies a nominal 5 v from two pins, one on each screw-terminal block. you can use the voltage source, which is provided by the usb host, to power external components. the USB-6501 features current limiting short circuit protection for safe usb host power use. software the USB-6501 is shipped with ni-daqmx measurement services software, a high-performance multithreaded driver for interactive con?uration and data acquisition. use it to develop customized data acquisition applications with ni labview or c-based development environments. examples include an interactive control panel to help you get started with your application quickly. recommended accessories the USB-6501 has built-in screw terminals for connectivity; no additional accessories are required. board-only version for oems a board-only version of the USB-6501 is available to oems for use in embedded applications. the oem version offers a 34-pin idc ribbon cable header for mass termination instead of screw-terminal connectivity. you can mount the oem version using standoffs (not included in kit) with your own enclosure. for information on special con?urations and pricing, visit ni.com/oem . low-cost digital i/o device for usb 2 buy online at ni.com or call 800 813 3693 (u.s.) figure 3. interactive control panel example program shipped with the USB-6501 i/o connector gnd switch ttl signal +5 v +5 v led led 1 2 3 4 p0.0 p0.1 p0.2 p0.3 p0.4 p0.5 p0.6 p0.7 1. p0.0 con?ured as an open-drain digital output driving an led 2. p0.2 con?ured as a push-pull digital output driving an led 3. p0.4 con?ured as a digital input receiving a ttl signal from a gated inverter 4. p0.7 con?ured as a digital input receiving a 0 v or 5 v signal from a switch figure 2. example of connecting a load ordering information ni USB-6501 ..........................................................................779205-01 includes ni-daqmx base software and a usb cable. ni USB-6501 hardware only (for oem) ................................192317-50 buy now! for complete product speci?ations, pricing, and accessory information, call 800 813 3693 (u.s.) or go to ni.com/daq .
speci?ations the following speci?ations are typical at 25 ?, unless otherwise noted. digital i/o number of lines p0.<0..7>.............................................. 8 p1.<0..7>.............................................. 8 p2.<0..7>.............................................. 8 direction control ................................. input or output, software-selectable output driver type ............................... push-pull or open-drain, software-selectable pull-up resistor.................................... 4.7 k absolute voltage range....................... -0.5 to 5.8 v with respect to gnd power-on state.................................... input (high impedance) digital logic levels counter number of counters ............................ 1 (p2.7 can be con?ured as the counter) resolution ........................................... 32 bits counter measurements....................... falling edge counting maximum input frequency.................. 5 mhz minimum high pulse width................. 100 ns minimum low pulse width.................. 100 ns bus interface usb speci?ation................................ usb full-speed (12 mb/s) external voltage +5 v output voltage............................................ 4.00 v min, 5.25 v max current ............................................ 230 ma max power requirements usb 4.5 to 5.25 vdc............................... 80 ma typical, 500 ma max usb suspend .................................. 500 ? max, all dio lines disconnected physical characteristics dimensions without connectors ........................ 6.35 by 8.51 by 2.31 cm (2.50 by 3.35 by 0.91 in.) with connectors ............................. 8.18 by 8.51 by 2.31 cm (3.22 by 3.35 by 0.91 in.) i/o connectors..................................... usb series b receptacle, (2) 16 position (screw-terminal) plug headers screw-terminal wiring ........................ 16 to 28 awg copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end torque for screw terminals................. 0.22 to 0.25 n ?m (2.0 to 2.2 lb ?in.) weight................................................. 84 g (3 oz) safety standards the USB-6501 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: iec 61010-1, en 61010-1 ul 61010-1 csa 61010-1 note: for ul and other safety certi?ations, refer to the product label, or visit ni.com/certi?ation , search by model number or product line, and click the appropriate link in the certi?ation column. overvoltage protection connect only voltages that are within these limits. channel-to-com (one channel) .......... ?0 v max, measurement category i channel-to-com (one port, all channels) ....................... ?.9 v max, measurement category i measurement category i is for measurements performed on circuits not directly connected to the electrical distribution system referred to as mains voltage. mains is a hazardous live electrical supply system that powers equipment. this category is for measurements of voltages from specially protected secondary circuits. such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. caution: do not use this module for connection to signals or for measurements within measurement categories ii, iii, or iv. hazardous locations the USB-6501 is not certi?d for use in hazardous locations. environmental the USB-6501 device is intended for indoor use only. operating temperature (iec 60068-2-1 and iec 60068-2-2)..... 0 to 55 c operating humidity (iec 60068-2-56) ............................. 10 to 90% rh, noncondensing maximum altitude............................... 2,000 m (at 25 ? ambient temperature) storage temperature (iec 60068-2-1 and iec 60068-2-2)... -40 to 85 c storage relative humidity (iec 60068-2-56) ............................. 5 to 90%, noncondensing pollution degree (iec 60664) .............. 2 low-cost digital i/o device for usb 3 buy online at ni.com or call 800 813 3693 (u.s.) level min max units input low voltage -0.3 0.8 v input high voltage 2.0 5.8 v input leakage current 50 ? output low voltage (i = 2 ma) 0.4 v output low voltage (i = 8.5 ma) 0.8 v output high voltage push-pull, i = -2 ma 2.8 3.6 v push-pull, i = -8.5 ma 2.0 3.5 v open-drain, i = -0.4 ma, nominal 2.0 5.0 v open-drain, i = -7.5 ma, with external pull-up resistor 2.0 v
electromagnetic compatibility emissions ............................................ en 55011 class a at 10 m fcc part 15a above 1 ghz immunity.............................................. industrial levels per en 61326:1997 + a2:2001, table 1 emc/emi............................................. ce, c-tick, and fcc part 15 (class a) compliant note: for emc compliance, operate this device with shielded cabling. ce compliance this product meets the essential requirements of applicable european directives, as amended for ce marking, as follows: low-voltage directive (safety) ........... 73/23/eec electromagnetic compatibility directive (emc)............................... 89/336/eec note: refer to the declaration of conformity (doc) for this product for any additional regulatory compliance information. to obtain the doc for this product, visit ni.com/certi?ation , search by model number or product line, and click the appropriate link in the certi?ation column. safety guidelines caution: operate the hardware only as described in these operating instructions. the following section contains important safety information that you must follow when installing and using the USB-6501. do not operate the USB-6501 in a manner not speci?d in this document. misuse of the device can result in a hazard. you can compromise the safety protection built into the device if the device is damaged in any way. if the device is damaged, contact national instruments for repair. do not substitute parts or modify the device except as described in this document. use the device only with the chassis, modules, accessories, and cables speci?d in the installation instructions. you must have all covers and ?ler panels installed during operation of the device. do not operate the device in an explosive atmosphere or where there may be ?mmable gases or fumes. if you must operate the device in such an environment, it must be in a suitably rated enclosure. if you need to clean the device, use a dry cloth. make sure that the device is completely dry and free from contaminants before returning it to service. operate the device only at or below pollution degree 2. pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resistivity. the following is a description of pollution degrees: pollution degree 1 means no pollution or only dry, nonconductive pollution occurs. the pollution has no in?ence. pollution degree 2 means that only nonconductive pollution occurs in most cases. occasionally, however, a temporary conductivity caused by condensation must be expected. pollution degree 3 means that conductive pollution occurs, or dry, nonconductive pollution occurs that becomes conductive due to condensation. you must insulate signal connections for the maximum voltage for which the device is rated. do not exceed the maximum ratings for the device. do not install wiring while the device is live with electrical signals. do not remove or add connector blocks when power is connected to the system. avoid contact between your body and the connector block signal when hot swapping modules. remove power from signal lines before connecting them to or disconnecting them from the device. operate the device at or below measurement category i 1 . measurement circuits are subjected to working voltages 2 and transient stresses (overvoltage) from the circuit to which they are connected during measurement or test. measurement categories establish standard impulse withstand voltage levels that commonly occur in electrical distribution systems. the following is a description of measurement categories: measurement category i is for measurements performed on circuits not directly connected to the electrical distribution system referred to as mains 3 voltage. this category is for measurements of voltages from specially protected secondary circuits. such voltage measurements include signal levels, special equipment, limited- energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. 1 measurement category as de?ed in electrical safety standard iec 61010-1. measurement category is also referred to as installation category. 2 working voltage is the highest rms value of an ac or dc voltage that can occur across any particular insulation. 3 mains is de?ed as a hazardous live electrical supply system that powers equipment. suitably rated measuring circuits may be connected to the mains for measuring purposes. measurement category ii is for measurements performed on circuits directly connected to the electrical distribution system. this category refers to local-level electrical distribution, such as that provided by a standard wall outlet (for example, 115 v for u.s. or 230 v for europe). examples of measurement category ii are measurements performed on household appliances, portable tools, and similar e series devices. measurement category iii is for measurements performed in the building installation at the distribution level. this category refers to measurements on hard-wired equipment such as equipment in ?ed installations, distribution boards, and circuit breakers. other examples are wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the ?ed installation, and stationary motors with permanent connections to ?ed installations. measurement category iv is for measurements performed at the primary electrical supply installation (<1,000 v). examples include electricity meters and measurements on primary overcurrent protection devices and on ripple control units. low-cost digital i/o device for usb 4 buy online at ni.com or call 800 813 3693 (u.s.)
ni services and support ni has the services and support to meet your needs around the globe and through the application life cycle ?from planning and development through deployment and ongoing maintenance. we offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. visit ni.com/services . training and certi?ation ni training is the fastest, most certain route to productivity with our products. ni training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. we schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. we also offer a professional certi?ation program that identi?s individuals who have high levels of skill and knowledge on using ni products. visit ni.com/training . professional services our professional services team is composed of ni applications engineers, ni consulting services, and a worldwide national instruments alliance partner program of more than 600 independent consultants and integrators. services range from start-up assistance to turnkey system integration. visit ni.com/alliance . oem support we offer design-in consulting and product integration assistance if you want to use our products for oem applications. for information about special pricing and services for oem customers, visit ni.com/oem . local sales and technical support in offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. ni delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within ni developer exchange forums. find immediate answers to your questions at ni.com/support . we also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. visit ni.com/ssp . hardware services ni factory installation services ni factory installation services (fis) is the fastest and easiest way to use your pxi or pxi/scxi combination systems right out of the box. trained ni technicians install the software and hardware and con?ure the system to your speci?ations. ni extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with fis. to use fis, simply con?ure your system online with ni.com/pxiadvisor . calibration services ni recognizes the need to maintain properly calibrated devices for high-accuracy measurements. we provide manual calibration procedures, services to recalibrate your products, and automated calibration software speci?ally designed for use by metrology laboratories. visit ni.com/calibration . repair and extended warranty ni provides complete repair services for our products. express repair and advance replacement services are also available. we offer extended warranties to help you meet project life-cycle requirements. visit ni.com/services . ?2007 national instruments corporation. all rights reserved. cvi, labview, national instruments, national instruments alliance partner, ni, ni.com, and scxi are trademarks of national instruments. the mark labwindows is used under a license from microsoft corporation. linux is a registered trademark of linus torvalds in the u.s. and other countries. other product and company names listed are trademarks or trade names of their respective companies. a national instr uments alliance partner is a business entity independent from ni and has no agency, partnership, or joint-venture relationship with ni. national instruments ? info@ni.com ni.com 800 813 3693 *351483a-01* 351483a-01 2007-8562-301-101-d


▲Up To Search▲   

 
Price & Availability of USB-6501

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X