small flange remote seal type differential pressure transmitter features the fcx -a iii small ange remote seal type differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capacitance silicon sensor with state- of-the-art microprocessor technology to provide exceptional performance and functionality. totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. 1. directly connectable to 1- 1 /2 in and 2in anges the transmitter is connectable to 1- 1 /2 in and 2in pipes without a reducer. 2. flow measurement without impulse piping 1 /2 in and 3 /4 in ange size is also available. this differ- ential pressure transmitter allows connection to 1 /2 in and 3 /4 in anges of a general size for the ori ce tap, which eliminates the need of using a impulse piping. problems with the impulse piping, such as clogging, leaks or corrosion can be solved. in addition, the fol- lowing process connection is also available. screw connection 1 /2 -14npt, 3 /4 -14npt, rc 1 /2 , rc 3 /4 3. minimum environmental in uence the advanced floating cell?design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual eld applications. 4. fuji/hart bilingual communications protocol fcx -a iii series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcx -a iii . 5. application exibility various options that render the fcx -a iii suitable for almost any process applications include: ? full range of hazardous area approvals ? built-in rfi lter and lightning arrester ?5 -digit lcd meter with engineering unit ? stainless steel electronics housing ? wide selection of materials ? high temperature, high vacuum seals 6. programmable output linearization function in addition to linear and square root, output signal can be freely programmable. (up to 14 compensated points at approximation.) 7. burnout current exibility (under scale: 3.2 to 4.0ma, over scale: 20.0 to 22.5ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 8. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. specifications functional speci cations service: liquid, gas, or vapour static pressure, span, and range limit: ? maximum static pressure limit for screw connction type: 4.2mpa ? lower limit of static pressure (vacuum limit), silicone ll sensor: see fig. 1 fluorinated ll sensor: atmospheric pressure ? the maximum span of each sensor can be converted to different units using factors as below. 1mpa =10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.976mmh 2 o=4.01463h 2 o up to ange rating f kx 3 f kx 5 f kx 6 +/? 32 {+/? 320} +/? 130 {+/? 1300} +/? 500 {+/? 5000} 3 { 30} 13 {130} 50 {500} 32 { 320 } 130 { 1300 } 500 { 5000 } min. type range limit [kpa] {m bar} span limit [kpa] (m bar} max. static pressure data sheet fkx ... 5 date EDSX6-137H aug. 10, 2011
2 fkx ... 5 lower limit of static press. process temperature atmospheric pressure fill uid 13th digit of code symbols ?20 to 120? 0 to 250? ?40 to 180? 0 to 250? w, a and d h y and g s fluorinated oil silicone oil 2.7kpa abs {20mmhg abs} (note) (1) hhc: hand held communicator overrange limit: to maximum static pressure limit output signal: 4 to 20ma dc (linear or square root) with digital signal superimposed on the 4 to 20ma signal. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see gure below note: for communication with hhc (1) (model: fxw), min. of 250 ? is required. hazardous locations: see table2 zero/span adjustment: zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw. damping: adjustable from hhc or local con gurator unit with lcd display. the time constant is adjustable between 0.06 to 32 seconds. zero elevation/suppression: ?100% to +100% of url normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as speci ed. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter failure, the analog signal will be driven to either output hold? output overscale?or output underscale?modes. output hold? output signal is hold as the value just before failure happens. output overscale? adjustable within the range 20.0ma to 22.5ma from hhc (1) output underscale? adjustable within the range 3.2ma to 4.0ma from hhc (1) 3.2 4 20 22.5 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout output limits conforming to namur ne43 by order. loop-check output: transmitter can be con gured to provide constant signal 3.2ma through 22.5ma by hhc (1) . storage: ?40 to +70? humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following items can be remotely displayed or con gured. note: hhc? version must be higher than 7.0 (or fxw 1? 4), for fcx? iii . local con gurator with lcd display (option): local con gurator with 3 push button and lcd display can support following items. items by communication with fxw by local con gurator (with 3 push button) display set display set tag no. vvvv model no. vvvv serial no. & software version v v engineering unit vvvv range limit v v measuring range vvvv damping vvvv output mode linear vvvv square root vvvv burnout direction vvvv calibration vvvv output adjust v v data v v self diagnoses v v printer (in case of fxw with printer option) v external switch lock vvvv transmitter display vvvv linearize vv rerange vvvv saturate current vvvv write protect vvvv history ?calibration history ?ambient temperature history v v v v v v programmable output linearization function: output signal can be characterized with ?4 points linear approximation function? from hhc (1) . emc conformity: en61326-1: 2006 2000 [] 1500 1000 load resistance 500 250 0 1474 577 operating area 24v 45v 10 16.35 50 e[ v ] 10.5v power voltage (dc) r= e-10.5 (imax+0.9)x10 -3 temperature limit: ambient: ?15 to + 65? (?15 to + 60? for arrester option) (?10 to + 60? for uorinated oil ll transmitter) (?10 to + 60? for silicone oil ? , ?? (?15 to + 45? for capillary length more than 7m) for explosionproof units ( ameproof or intrinsic safety), ambient temperature must be within the limits speci- ed in each standard. process: 3 performance speci cations reference conditions, silicone oil ll, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode and capillary length 3m. accuracy rating: (including linearity, hysteresis, and re- peatability) (standard) for spans greater than 1 /10 of url: 0.25% of span for spans below 1 /10 of url: (option) (code; 21th digit h,k) for spans greater than 1 /10 of url: 0.1% of span for spans below 1 /10 of url: stability: ?.2% of upper range limit (url) for 10 years. temperature effect: effects per 28? change between the limits of ?15? and +65? url 2 x static pressure effect: zero shift; 0.2% of url/1mpa (10 bar) span shift: ?0.2% of calibrated span /1mpa overrange effect: zero shift; 0.1% of url for ange rating pressure supply voltage effect: less than 0.005% of calibrated span per 1v update rate: 60 msec step response: (without electrical damping) ? 0.17+0.08 % of span 0.1 x url span () () ? 0.05+0.05 % of span 0.1 x url span time constant (at 23?) 1.7 s dead time 0.12 s dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? at 500v dc. internal resistance for external eld indicator: 12 ? or less zero shift: ?.5%/28? ( x equal to 1 /2 url or more) zero shift; ?(0.5 )%/28? ( x less than 1 /2 url) total shift; ?.75%/28? ( x less than 1 /2 url or more) total shift; ?0.25 + 0.5 )%/28? ( x less than 1 /2 url) (option) (code; 21th digit j,k) zero shift: ?.5%/28? ( x equal to 1 /6.5 url or more) zero shift; ?(0.5 )%/28? ( x less than 1 /6.5 url) total shift; ?.75%/28? ( x equal to 1 /6.5 url or more) total shift; ?0.25 + 0.5 )%/28? ( x less than 1 /6.5 url) where, x : calibrated span url: maximum span (upper range limit) note : above specifications are based on the conditions that anges and sensor unit are at the same temperature and in the same level. if temperature is different at anges, capillary or sensor unit, output variation may increase. url 2 x url 6.5 x url 6.5 x 4 fkx ... 5 accessories fig. 1 r elation between process temperature and operating pressure 180 operating area non-operating area 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {m bar abs} operating pressure C40 0 60 85 120 230 250 process temperature silicone (code y,g) filled liquid: [c ] silicone (code s) physical speci cations electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 x 1.5 con- duit, as speci ed. process connections: jis 10k, 20k, 30k - 40, 50a 10k, 20k, 30k - 15, 20a (with adapter) ansi/jpi 150lb, 300lb -1 1 /2 ", 2" 150lb, 300lb - 1 /2 ", 3 /4 " (with adapter) screw connection (with adapter); rc 1 /2 , rc 3 /4 , 1 /2 - 14npt, 3 /4 - 14npt diaphragm extension: 0, 50, 100, 150, or 200mm as speci ed. (see model code. extended diaphragm is available only with 316l stainless steel diaphragm) process-wetted parts material: diaphragm:316l stainless steel, hastelloy-c, monel or tantalum flange face: 316 stainless steel, hastelloy- c lining monel lining, or tantalum lining extension: 316 stainless steel non-wetted parts material: electronics housing: low copper die-cast aluminum alloy nished with polyester coating (standard), or 316 stainless steel (astm cf8m), as speci ed. capillary: in case of 11th code ?. e. l.? pe armored stainless steel. in case of 11th code ?. r. s? stain- less steel armored stainless steel. mounting ange: 304 stainless steel or carbon steel. fill uid: silicone oil (standard) or uori- nated oil mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting mass {weight}: transmitter approximately 12.7 to 30.7kg without options. add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option 1.5kg per 50mm extension of dia- phragm optional features indicator: a plug-in analog indicator (2.5% accuracy) can be housed in the electronics compart- ment or in the terminal box of the hous- ing. an optional 5-digit lcd meter with engi- neering unit is also available. local con gurator with lcd display: an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 50?). oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the ll uid is uorinated oil. chlorine service: oil-free procedures as above. includes uorinated oil for ll. degreasing: process-wetted parts are cleaned, but the ll uid is standard silicone oil. not for use on oxygen or chlorine measurement. vacuum service: special silicone oil and lling procedure are applied. see fig. 1. optional tag plate: an extra stainless steel tag for customer tag data is wired to the transmitter. coating of cell: cell's surface is nished with epoxy/poly- urethane double coating. specify if envi- ronment is extremely corrosive. hand-held communicator: (model fxw, refer to data sheet no. eds 8-47) 5 6 fkx ... 5 7 8 fkx ... 5 ordering information when ordering this instrument, specify: 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occurred in the transmitter. hold / overscale / underscale unless otherwise speci ed, output hold function is sup- plied. 4. output mode (linear or square root output) unless otherwise speci ed, output mode is linear. 5. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s, 2, 5 on 9th digit). 6. tag no. (up to 14 alphanumerical characters), if required. 9 - / 1 5 5 1 h 7 . 8 " ? # ? $ ? % ? % 2 u i e j h j u p g u i f d p e f t z n c p m t 4 n & |