  94x series (942-o4n-2d-1a1/1a2-80e, 943-o4v-2d-001/002/1c0/1d0-80e, 947-o4v-2d-1 c0/1d0-80e) ultrasonic distance sensors description this collection of ultrasonic devices offers enhanced sensing range capability in a square plastic housing. available sensor types include programmable, teach-in, and analogue and fixed output versions. features ? non contact distance sensing for use in non invasive measurement ? reduced sensitivity to light intensity/reflectivity/opacity of target for enhanced flexibility and certainty of measurement ? detects over much longer distance than other detection methods reducing the need for close proximity to the target ? extremely long sensing distance (up to 6 m [19.65 ft]) reducing the need for close proximity measurement which can be critical for some applications potential applications ? level measurement ? presence/absence detection ? distance measurement
943 series (942-o4n-2d-1a1/1a2-80e, 943-o4v-2d-001/002/1c0/1d0-80e, 947-o4v-2d-1c0/1d0-80e) 2 www.honeywell.com/sensing specifications parameter 942-o4n-2d- 1a1-80e 942-o4n-2d- 1a2-80e 943-o4v-2d- 001-80e 943-o4v-2d- 002-80e 943-o4v-2d- 1c0-80e 943-o4v-2d- 1d0-80e 947-o4v-2d- 1c0-80e 947-o4v-2d- 1d0-80e max. sensing distance 6000 mm [236.22 in] 5000 mm [196.85 in] min. sensing distance 600 mm [23.62 in] 500 mm [19.69 in] expected response time 90% of final value 250 ms/prog ? 700 ms 400 ms beam angle 8 o 10 o switching frequency 7 hz/prog 0.5 hz 7 hz/prog linearity error <0.3% ? <0.5 % hysteresis prog ~1% ? repeatability of measured distance 0.2% ? 0.2% 2 mm [0.08 in] 0.2% temperature range -15 c to 70 c [-5 f to 158 f] temperature compensation yes ? operating voltage 15 vdc to 30 vdc 12 vdc to 30 vdc 15 vdc to 30 vdc 24 vdc 20% expected current consumption 100 ma <80 ma <35 ma <40 ma analogue output 0 v to 10 v/4 ma to 20 ma ? 0 v to 10 v 4 ma to 20 ma 0 v to 10 v 4 ma to 20 ma analogue output selection by load load >2 kohm uout load <500 ohm iout ? switching outputs 2 pnp no/nc 2 npn no/nc 2 pnp no/nc 2 npn no/nc ? expected output current 100 ma max. 500 ma max. ? adjustment programming teach-in ? alignment led status switching output 1 status switching output 2 green (1) yellow (2) yellow (3) ? control input inhibit connect to: synchronisation connect to: enable connect to: pin 6 0 v pin 6 ? pin 6 pin 6 nc ? pin 2 0 v pin 2 ? pin 2 pin 2 nc interface rs232 ? plastic housing pbpt sealing* ip65 connector 8 pin m16x0.75 5 pin m12x1 *attention! do not expose sensor head to hot water >50 c or steam vapour. accessories: 942-o4n-2d-1a1/1a2-80e catalog listing description 66195126-001 mating connector straight 55000005-002 programming adaptor 55000010-001 software programming adaptor and pc connection cable 55000018-001 programming cable accessories: 943-o4v-2d-001/002-80e, 943-o4v- 2d-1c0/1d0-80e, 947-o4v-2d-1c0/1d0-80e catalog listing description 66195044-001 mating connector straight 66195045-001 mating connector angled 66195214-001 straight cable/connector 2 m 66195216-001 right-angle cable/connector 2 m
ultrasonic distance sensors honeywell sensing and control 3 mounting dimensions (for reference only. mm/[in]) 942-o4n-2d-1a1/1a2-80e 943-o4v-2d-001/002/1c0/1d0-80e, 947-o4v-2d-1c0/1d0-80e wiring p42-o4n-2d-1a1/1a2-80e 943-O4V-2D-001-80E view to solder pins of connector 1 2 3 4 5 8 76 pin 1: + 24 vdc pin 2: gnd pin 3: u/i pin 4: sp1 pin 5: sp2 pin 6: hld/sync pin 7: rxd pin 8: txd pin 1 pin 5 +24 vdc teach-in switching output sp1 0 v pin 4 pin 2 pin 3 switching output sp2 r r 12 3 4 5 943-o4v-2d-002-80e 943-o4v-2d-1c0/1d0-80e pin 1 pin 2 +24 vdc switching output 2 0 v pin 4 pin 5 pin 3 switching output 1 12 3 4 5 load load teach-in pin 1 pin 4 +24 v pin 5 pin 3 1 2 3 4 5 0 v/gnd analogue teach-in 947-o4v-2d-1c0/1d0-80e 947-o4v-2d-1c0-80e 947-o4v-2d-1d0-80e pin 1 pin 4 +24 vdc analogue output 0 v pin 2 pin 3 12 3 4 synchronisation enable inhibit 10 v 0 v 500 mm 5000 mm 20 ma 4 ma 500 mm 5000 mm
automation and control solutions sensing and control honeywell 1985 douglas drive north minneapolis, mn 55422 www.honeywell.com/sensing 004451-1-en il50 glo printed in usa february 2006 copyright ? 2006 honeywell international inc. all rights reserved. detection range 942-o4n-2d-1a1/1a2-80e, 943-04v-2d-001/002/1c0/1d0-80e 947-04v-2d-1c0/1d0-80e +1000 -1000 mm 0 600 6000 enhanced detection of a target 100 mm2 x 100 mm2 possible detection of a large target mm +600 -600 mm 0 500 5000 enhanced detection of a target 100 mm2 x 100 mm2 possible detection of a large target mm w arning personal injury do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. failure to comply with these instructions could result in death or serious injury. warranty/remedy honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. honeywell?s standard product warranty applies unless agreed to otherwise by honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. if warranted goods are returned to honeywell during the period of coverage, honeywell will repair or replace, at its option, without charge those items it finds defective. the foregoing is buyer?s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. in no event shall honeywell be liable for consequential, special, or indirect damages. while we provide application assistance personally, through our literature and the honeywell web site, it is up to the customer to determine the suitability of the product in the application. specifications may change without notice. the information we supply is believed to be accurate and reliable as of this printing. however, we assume no responsibility for its use. w arning misuse of documentation ? the information presented in this product sheet is for reference only. do not use this document as a product installation guide. ? complete installation, operation, and maintenance information is provided in the instructions supplied with each product. failure to comply with these instructions could result in death or serious injury. sales and service honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. for application assistance, current specifications, pricing or name of the nearest authorized distributor, contact your local sales office or: e-mail: info.sc@honeywell.com internet: www.honeywell.com/sensing phone and fax: asia pacific +65 6355-2828 +65 6445-3033 fax europe +44 (0) 1698 481481 +44 (0) 1698 481676 fax latin america +1-305-805-8188 +1-305-883-8257 fax usa/canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 fax


▲Up To Search▲   

 
Price & Availability of 943-O4V-2D-001-80E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X