pc series data sheet 190 - 230 watt ac-dc converters rev. may 12, 2004 page 1 of 4 ? extremely slim case (4te), fully enclosed single outputs for 72 and 85 vdc loads ideal to supply isolated p series dc-dc converters operating ambient temperature range ?40 to 71c with convection cooling converter with single stage ac to dc con- version and pfc no electrical isolation input to output input voltage range 85(95) - 255 v ac input input voltage continuous range 85(95) - 255 v ac input frequency 47 - 63 hz inrush current extremely low input capacitance of 1.25 f negligible output efficiency v i nom , i o nom 94% output voltage setting accuracy v i nom , i o nom 2 v v o nom output voltage noise iec/en 61204, low frequency typ. 5 v pp iec/en 61204, switching frequency typ. 25 mv pp line regulation v i min - v i max , i o nom typ. 1 v load regulation v i nom , 10 - 100% i o nom typ. 250 mv v i nom , 0 - 10% i o nom typ. 700 mv minimum output current not required 0 a power limitation approx. 1 s, restart after 3 s typ. 240 w current limitation approx. 1 s, restart after 3 s typ. 200% i o nom operation in parallel by load regulation up to 5 units hold-up time v o = 72 - 66 vdc, p o = 190 w typ. 4.3 ms v o = 85 - 40 vdc, p o = 230 w typ. 24 ms model selection output 1 input voltage rated power efficiency type options v o nom i o nom v i p o max h [vdc] [a] [v ac] [w] [%] 72 2.7 85 - 255 190 94 lpc 1901-7d -9 85 2.7 95 - 255 230 94 lpc 1902-7d -9 model numbers highlighted in yellow or schaded are not recommded for new designs. lg a
pc series data sheet 190 - 230 watt ac-dc converters rev. may 12, 2004 page 2 of 4 protection input undervoltage lockout typ. 68 v ac input overvoltage lockout typ. 306 v ac input transient protection two varistors output no-load, overload and short circuit proof output overvoltage suppressor diode in each output typ. 150% v o nom overtemperature switch-off with auto restart t c typ. 110c control status indication led: ok isolated open collector signal in ok/out ok feature d safety approvals en 60950, ul 1950, csa c22.2 no. 950 class of equipment class i protection degree ip 40 electric strength test voltage i/case and o/case 1.5 kv ac emc electrostatic discharge iec/en 61000-4-2, contact/air, level 2/3 (4/8 kv) criterion b electromagnetic field iec/en 61000-4-3, level 2 (3 v/m) criterion a electr. fast transients/bursts iec/en 61000-4-4, level 3 (2 kv) criterion b surge iec/en 61000-4-5, input, level 2/3 (1/2 kv) criterion b conducted disturbances iec/en 61000-4-6, level 2 (3 v) criterion a electromagnetic emissions cispr 22/en 55022, conducted class b cispr 14/en 55014, radiated below limit environmental operating ambient temperature v i nom , i o nom , convection cooled ?25 to 71c operating case temperature t c v i nom , i o nom ?25 to 95c storage temperature non operational ?40 to 100c damp heat iec/en 60068-2-3, 93%, 40c 56 days vibration, sinusoidal iec/en 60068-2-6, 10 - 60/60 - 150 hz 0.35 mm/5 g n shock iec/en 60068-2-27, 11 ms 50 g n bump iec/en 60068-2-29, 11 ms 25 g n random vibration iec/en 60068-2-64, 20 - 500 hz 4.9 g n rms mtbf mil-hdbk-217e, g b , 40c, notice 2 763'000 h options extended temperature range ?40 to 71c, ambient, operating -9
pc series data sheet 190 - 230 watt ac-dc converters rev. may 12, 2004 page 3 of 4 mechanical data tolerances 0.3 mm (0.012") unless otherwise indicated. european projection 104 (4.09") 65 (2.56") 111 (4.37") 20 (0.79") 127 (5.18") 164 (6.46") 8 (0.31") 19.8 (0.78") potentiometer (option p) led "out ok" 171.93 (din 41494) (6.76") s09106 m3, 4 deep measuring point of case temperature t c 35 (1.38")
pc series data sheet 190 - 230 watt ac-dc converters rev. may 12, 2004 page 4 of 4 30 26 22 18 14 10 6 s10025 32 28 24 20 16 12 8 4 pin allocation pin no. electrical determination 4 output voltage negative vo? 6 output voltage positive vo+ 8 phase p 10 neutral n 12 protective earth 14 protective earth 16 - n.c. 18 - n.c. 20 output good out ok+ 22 output good out ok? 24 - n.c. 26 output voltage positive vo+ 28 output voltage negative vo? 30 output voltage positive vo+ 32 output voltage negative vo? accessories front panels 19? (schroff/intermas) mating h11 connectors with screw, solder, fast-on or press-fit terminals connector retention facilities and code key system for connector coding flexible pcb for connecting the converter via an h11 connector, if mounted on a pcb chassis or wall mounting plates for frontal access universal mounting brackets for chassis or din-rail mounting nuclear and medical applications - power-one products are not authorized for use as critical compo- nents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.
|